Feeder clamps for overhead contact lines

被引:0
|
作者
Biesenack, Hartmut [1 ]
Dölling, André [1 ]
Schmieder, Axel [2 ]
机构
[1] TU Dresden, Fakultät Verkehrswissen-schaften Friedrich List, Institut für Elektrische Verkehrssysteme, Hettnerstr. 1-3, 01069 Dresden, Germany
[2] Siemens AG, TS EL EN, Postfach 3240, 91050 Erlangen, Germany
来源
eb - Elektrische Bahnen | 2006年 / 104卷 / 07期
关键词
Bolted joints - Current limiting reactors - Electric conductors - Electric power systems;
D O I
暂无
中图分类号
学科分类号
摘要
Bolted as well as compressed current-carrying connections are used in overhead contact line installations. While compressed connections are aging to a low extent only, aging can change the characteristics of bolted connections significantly. The tightening force of bolts, the connection resistance, the Joule's heat and the surface conditions of the connected conductors establish the most important impact parameters. When replacing bolted clamps in existing installations the connecting conductors should be replaced as well. Heat cycle tests according to DIN EN 61284 are suited to assess the correct design of feeder clamps but not to forecast their long-term aging behaviour.
引用
收藏
页码:336 / 343
相关论文
共 50 条
  • [1] Development of single copper feeder messenger wire for overhead contact lines
    Iwainaka, A
    Suzuki, A
    Shimodaira, Y
    COMPUTERS IN RAILWAYS VII, 2000, 7 : 703 - 712
  • [2] INVESTIGATIONS ON THE LOAD OF CLAMPS OF OVERHEAD LINES.
    Eltschka, R.
    Transportation Research Record, 1976,
  • [3] Analysis of overhead transmission lines fusing failure due to poor contact between conductors and clamps
    Jin, Yingai
    Quan, Mingyu
    Yan, Shijuan
    Yan, Yuying
    Cui, Ming
    Liu, Yan
    ENGINEERING FAILURE ANALYSIS, 2020, 118
  • [4] Overhead contact lines - Design by computer
    Winter, Hubert
    eb - Elektrische Bahnen, 2016, 114 (8-9): : 460 - 467
  • [5] Sensors to diagnose overhead contact lines
    Fischer, Michael
    Puschmann, Rainer
    eb - Elektrische Bahnen, 2024, 122 (8-9): : 366 - 372
  • [6] Non-contact uplift measurement at overhead contact lines
    Hietzge, Jochen
    Stephan, Arnd
    eb - Elektrische Bahnen, 2007, 105 (4-5): : 276 - 279
  • [7] Room-temperature workability of 6063 alloy for fitting clamps of overhead conductor lines
    Zeng, L. R.
    Song, Z. M.
    Wu, X. M.
    Li, C. H.
    Zhang, G. P.
    MATERIALS & DESIGN, 2015, 65 : 187 - 192
  • [8] Contact of heavy vehicles with overhead power lines
    Koustellis, J. D.
    Anagnostatos, S. D.
    Halevidis, C. D.
    Karagrigoriou, F. S.
    Polykrati, A. D.
    Bourkas, P. D.
    SAFETY SCIENCE, 2011, 49 (06) : 951 - 955
  • [9] Thermal models for overhead contact lines and their validation
    Golle, Ingo
    Holderegger, Martin
    Steinegger, Urs
    eb - Elektrische Bahnen, 2015, 113 (10): : 498 - 511
  • [10] Automatic optic inspection of overhead contact lines
    Richter, U.
    Schneider, R.
    eb - Elektrische Bahnen, 2001, 99 (1-2): : 94 - 100