Evaluation of the Working Mechanism of a Newly Developed Powered Ankle-Foot Orthosis

被引:0
|
作者
Everaert, Laure [1 ]
Sevit, Roy [2 ]
Dewit, Tijl [1 ,3 ]
Janssens, Koen [2 ]
Vanloocke, Jolien [1 ]
Van Campenhout, Anja [4 ,5 ]
Labey, Luc [6 ]
Muraru, Luiza [2 ]
Desloovere, Kaat [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Fac Movement & Rehabil Sci, Dept Rehabil Sci, B-3001 Leuven, Belgium
[2] Thomas More Univ Appl Sci, Ctr Expertise Care & Well Being, Res Grp Mobilab & Care, Campus Geel, B-2440 Geel, Belgium
[3] Univ Hosp Leuven, Clin Mot Anal Lab, B-3000 Leuven, Belgium
[4] Katholieke Univ Leuven, Dept Dev & Regenerat, Fac Med, B-3001 Leuven, Belgium
[5] Univ Hosp Leuven, Dept Orthoped, Pediat Orthoped, B-3001 Leuven, Belgium
[6] Katholieke Univ Leuven, Fac Engn Technol, Dept Mech Engn, B-3001 Leuven, Belgium
关键词
cerebral palsy; ankle-foot orthosis; exoskeleton; biomechanics; gait; CEREBRAL-PALSY; CHILDREN; WALKING; GAIT; EXOSKELETON;
D O I
10.3390/s24206562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ankle-foot orthoses (AFOs) are commonly prescribed to children with cerebral palsy (CP). The conventional AFO successfully controls the first and second ankle rocker, but it fails to correct the third ankle rocker, which negatively effects push-off power. The current study evaluated a new powered AFO (PAFO) design, developed to address the shortcomings of the conventional AFO. Eight children with spastic CP (12.4 +/- 3.4 years; GMFCS I-III; 4/4-male/female; 3/5-bi/unilateral) were included. Sagittal kinematic and kinetic data were collected from 20 steps during barefoot walking, with conventional AFOs and PAFOs. In the PAFO-condition, an actuation unit was attached to a hinged AFO and through push-pull cables to a backpack that was carried by the child and provided patient-specific assistance-as-needed. SnPM-analysis indicated gait cycle sections that differed significantly between conditions. For the total group, differences between the three conditions were found in ankle kinematics (49.6-66.1%, p = 0.006; 88.0-100%, p = 0.011) and angular velocity (0.0-6.0%, p = 0.001; 45.1-51.1%, p = 0.006; 62.2-73.0%, p = 0.001; 81.2-93.0%, p = 0.001). Individual SnPM-analysis revealed a greater number of significant gait cycle sections for kinematics and kinetics of the ankle, knee, and hip. These individual results were heterogeneous and specific per gait pattern. In conclusion, the new PAFO improved the ankle range-of-motion, angular velocity, and power during push-off in comparison to the conventional AFO.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A Powered Ankle-Foot Orthoses for Ankle Rehabilitation
    Bai, Yang
    Li, Fangxing
    Zhao, Jun
    Li, Jingyi
    Jin, Fei
    Gao, Xueshan
    2012 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS (ICAL), 2012, : 288 - 293
  • [32] Design of a Portable Hydraulic Ankle-Foot Orthosis
    Neubauer, Brett C.
    Nath, Jonathan
    Durfee, William K.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1182 - 1185
  • [33] STIFFNESS ANALYSIS OF A SIMPLIFIED ANKLE-FOOT ORTHOSIS
    Swierski, Ethan
    Burke, Molly
    Arenas, Maria
    Bernat, Jessica
    Manzer, James
    Piovesan, Davide
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5, 2020,
  • [34] KNEE-STABILIZING ANKLE-FOOT ORTHOSIS
    RUBIN, G
    DANISI, M
    ORTHOTICS AND PROSTHETICS, 1975, 29 (03): : 11 - 14
  • [35] AN IMPROVED ANKLE-FOOT ORTHOSIS FOR CORRECTION OF EQUINUS
    PINZUR, MS
    GAVIN, T
    ORTHOPEDICS, 1984, 7 (02) : 263 - 264
  • [36] Development of an ankle-foot orthosis with an oil damper
    Yamamoto, S
    Hagiwara, A
    Mizobe, T
    Yokoyama, O
    Yasui, T
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (03) : 209 - 219
  • [37] Modulation of Anticipatory Postural Adjustments of Gait Using a Portable Powered Ankle-Foot Orthosis
    Petrucci, Matthew N.
    Hsiao-Wecksler, Elizabeth T.
    MacKinnon, Colum D.
    2013 IEEE 13TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2013,
  • [38] Control of a 2-DOF powered ankle-foot mechanism
    Ficanha, Evandro M.
    Rastgaar, Mohammad
    Kaufman, Kenton R.
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 6439 - 6444
  • [39] GAIT MODELING FOR ASSESSMENT OF ANKLE-FOOT ORTHOSIS
    Jamshidi, N.
    Rostami, M.
    Najarian, S.
    Menhaj, M. B.
    Saadatnia, M.
    Farzad, A.
    2008 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE, 2008, : 146 - +
  • [40] Design and Evaluation of an Active/Semiactive Ankle-Foot Orthosis for Gait Training
    Zhang, Yufeng
    Kleinmann, Roger J.
    Nolan, Karen J.
    Zanotto, Damiano
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 544 - 549