Evaluation of the Working Mechanism of a Newly Developed Powered Ankle-Foot Orthosis

被引:0
|
作者
Everaert, Laure [1 ]
Sevit, Roy [2 ]
Dewit, Tijl [1 ,3 ]
Janssens, Koen [2 ]
Vanloocke, Jolien [1 ]
Van Campenhout, Anja [4 ,5 ]
Labey, Luc [6 ]
Muraru, Luiza [2 ]
Desloovere, Kaat [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Fac Movement & Rehabil Sci, Dept Rehabil Sci, B-3001 Leuven, Belgium
[2] Thomas More Univ Appl Sci, Ctr Expertise Care & Well Being, Res Grp Mobilab & Care, Campus Geel, B-2440 Geel, Belgium
[3] Univ Hosp Leuven, Clin Mot Anal Lab, B-3000 Leuven, Belgium
[4] Katholieke Univ Leuven, Dept Dev & Regenerat, Fac Med, B-3001 Leuven, Belgium
[5] Univ Hosp Leuven, Dept Orthoped, Pediat Orthoped, B-3001 Leuven, Belgium
[6] Katholieke Univ Leuven, Fac Engn Technol, Dept Mech Engn, B-3001 Leuven, Belgium
关键词
cerebral palsy; ankle-foot orthosis; exoskeleton; biomechanics; gait; CEREBRAL-PALSY; CHILDREN; WALKING; GAIT; EXOSKELETON;
D O I
10.3390/s24206562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ankle-foot orthoses (AFOs) are commonly prescribed to children with cerebral palsy (CP). The conventional AFO successfully controls the first and second ankle rocker, but it fails to correct the third ankle rocker, which negatively effects push-off power. The current study evaluated a new powered AFO (PAFO) design, developed to address the shortcomings of the conventional AFO. Eight children with spastic CP (12.4 +/- 3.4 years; GMFCS I-III; 4/4-male/female; 3/5-bi/unilateral) were included. Sagittal kinematic and kinetic data were collected from 20 steps during barefoot walking, with conventional AFOs and PAFOs. In the PAFO-condition, an actuation unit was attached to a hinged AFO and through push-pull cables to a backpack that was carried by the child and provided patient-specific assistance-as-needed. SnPM-analysis indicated gait cycle sections that differed significantly between conditions. For the total group, differences between the three conditions were found in ankle kinematics (49.6-66.1%, p = 0.006; 88.0-100%, p = 0.011) and angular velocity (0.0-6.0%, p = 0.001; 45.1-51.1%, p = 0.006; 62.2-73.0%, p = 0.001; 81.2-93.0%, p = 0.001). Individual SnPM-analysis revealed a greater number of significant gait cycle sections for kinematics and kinetics of the ankle, knee, and hip. These individual results were heterogeneous and specific per gait pattern. In conclusion, the new PAFO improved the ankle range-of-motion, angular velocity, and power during push-off in comparison to the conventional AFO.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Developing a Classification Algorithm for Plantarflexor Actuation Timing of a Powered Ankle-Foot Orthosis
    Islam, Mazharul
    Hsiao-Wecksler, Elizabeth T.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (03):
  • [22] Preliminary Design and Engineering Evaluation of a Hydraulic Ankle-Foot Orthosis
    Neubauer, Brett
    Durfee, William
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (04): : 1 - 9
  • [23] Experimental Implementation of Underactuated Potential Energy Shaping on a Powered Ankle-Foot Orthosis
    Lv, Ge
    Zhu, Hanqi
    Elery, Toby
    Li, Luwei
    Gregg, Robert D.
    2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2016, : 3493 - 3500
  • [24] Estimating System State During Human Walking With a Powered Ankle-Foot Orthosis
    Li, David Yifan
    Becker, Aaron
    Shorter, Kenneth Alex
    Bretl, Timothy
    Hsiao-Wecksler, Elizabeth T.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2011, 16 (05) : 835 - 844
  • [25] Ankle dorsiflexion assistance of patients with foot drop using a powered ankle-foot orthosis to improve the gait asymmetry
    Shin, Wonseok
    Nam, Dongwoo
    Ahn, Bummo
    Kim, Sangjoon J.
    Lee, Dong Yeon
    Kwon, Suncheol
    Kim, Jung
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2023, 20 (01)
  • [26] Ankle dorsiflexion assistance of patients with foot drop using a powered ankle-foot orthosis to improve the gait asymmetry
    Wonseok Shin
    Dongwoo Nam
    Bummo Ahn
    Sangjoon J. Kim
    Dong Yeon Lee
    Suncheol Kwon
    Jung Kim
    Journal of NeuroEngineering and Rehabilitation, 20
  • [27] Powered ankle-foot prosthesis
    Biomechatronics Group, MIT Media Lab., Cambridge, MA 02139, United States
    IEEE Rob Autom Mag, 2008, 3 (52-59):
  • [28] SEVERE ANKLE SPRAINS - TREATMENT WITH AN ANKLE-FOOT ORTHOSIS
    LANE, SE
    PHYSICIAN AND SPORTSMEDICINE, 1990, 18 (11): : 43 - &
  • [29] Use of bivalved ankle-foot orthosis in neuropathic foot and ankle lesions
    Boninger, ML
    Leonard, JA
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1996, 33 (01): : 16 - 22
  • [30] GAIT EMULATOR FOR EVALUATION OF A POWERED ANKLE-FOOT PROSTHESIS
    Ficanha, Evandro
    Dallali, Houman
    Rastgaar, Mo
    PROCEEDINGS OF THE ASME 10TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2017, VOL 1, 2017,