Gas-Liquid Two-Phase Flow Measurement With Throat-Extended Venturi Meter Based on Differential Pressure Ratios and Fluctuations

被引:0
|
作者
Suo, Peng [1 ,2 ]
Sun, Jiangtao [2 ]
Shi, Shiying [3 ]
Sun, Shijie [2 ]
He, Feng [4 ]
Zhang, Xiaokai [2 ]
Shen, Mengxian [2 ]
Li, Xiaolin [2 ]
Li, Jinfei [5 ]
Xu, Lijun [2 ]
机构
[1] Beihang Univ, Hangzhou Int Innovat Inst, Hangzhou 311115, Peoples R China
[2] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[3] Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China
[4] China Elect Technol Grp Corp, Res Inst 48, Changsha 410111, Peoples R China
[5] Dayanghuida Sci & Technol Co Ltd, Beijing 100048, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Differential pressure (DP) fluctuation; DP ratio (DPR); flow rate measurement; gas-liquid two-phase flow (GLTPF); throat-extended Venturi meter (TEVM); OIL;
D O I
10.1109/TIM.2024.3481576
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a novel approach to measuring gas-liquid two-phase flow (GLTPF) using a throat-extended Venturi meter (TEVM) based on differential pressure (DP) ratios and fluctuations. The over-reading (OR) and mass quality are the dominant parameters for accurate mass flow rate measurement by a TEVM. First, a liquid OR model is established based on multiple DP ratios (DPRs), gas-to-liquid density ratio (GLDR), and liquid densitometric Froude number. This model is solved by integrating a deep neural network (DNN) with an iterative optimization technique. Subsequently, a mass quality model is developed based on multi-DP fluctuations and other related parameters, which can also be solved using a DNN. Finally, the liquid and gas mass flow rates are obtained sequentially from the preceding results. The proposed method addresses the issue of significant errors in the direct solution of the conventional dual-parameter measurements. It utilizes both the static and dynamic features of multi-DP to achieve the simultaneous measurement of gas and liquid mass flow rates using a single TEVM. The experiment was conducted within a gas flow rate range of 1.3x10(-4)similar to 5.1x10(-3) kg/s, and a liquid flow rate range of 1.12 similar to 3.95 kg/s. The results demonstrate that the relative error for liquid and gas mass flow rates is within +/- 3% and +/- 10%, respectively. This indicates that the proposed method is a cost-effective and viable solution for GLTPF metering using a TEVM, and it can be further adapted to other experimental conditions.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Wet gas flow modeling for the straight section of throat-extended Venturi meter
    Zhou, Wanlu
    Xu, Lijun
    Li, Xiaomin
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [2] Erratum to “Measurement of gas-liquid two-phase slug flow with a Venturi meter based on blind source separation”
    Weiwei Wang
    Xiao Liang
    Mingzhu Zhang
    Chinese Journal of Chemical Engineering, 2015, 23 (11) : 1923 - 1923
  • [3] Wet-Gas Flow Modeling for the Straight Section of Throat-Extended Venturi Meter
    Xu, Lijun
    Zhou, Wanlu
    Li, Xiaomin
    Wang, Minghao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (06) : 2080 - 2087
  • [4] Measurment of gas-liquid two-phase slug flow with a Venturi meter based on blind source separation
    Wang, Weiwei
    Liang, Xiao
    Zhang, Mingzhu
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2015, 23 (09) : 1447 - 1452
  • [5] Void fraction measurement of gas-liquid two-phase flow from differential pressure
    Jia, Jiabin
    Babatunde, Akintayo
    Wang, Mi
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 41 : 75 - 80
  • [6] Gas-liquid two-phase flow measurement by using electrical tomography sensors and Venturi
    Hu, Chenjun
    Yu, Ling
    Wang, Dian
    He, Haitao
    Li, Yi
    FLOW MEASUREMENT AND INSTRUMENTATION, 2025, 102
  • [7] Influence of differential pressure fluctuation on flow measurement of gas-liquid two-phase flow in orifice plate
    Zheng, Xue-Bo
    Fan, Chen
    Che, Yu-Quan
    Bai, Bo-Feng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2016, 37 (10): : 2136 - 2141
  • [8] Study on Venturi nozzle for gas-liquid two-phase flow metering
    梁法春
    张修刚
    王栋
    林宗虎
    Journal of Harbin Institute of Technology(New series), 2012, (01) : 107 - 110
  • [9] Study on Venturi nozzle for gas-liquid two-phase flow metering
    梁法春
    张修刚
    王栋
    林宗虎
    Journal of Harbin Institute of Technology, 2012, 19 (01) : 107 - 110
  • [10] Measurement of gas-liquid two-phase slug flow with a Venturi meter based on blind source separation (vol 23, pg 1447, 2015)
    Wang, Weiwei
    Liang, Xiao
    Zhang, Mingzhu
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2015, 23 (11) : 1923 - 1923