Gas-liquid two-phase flow measurement by using electrical tomography sensors and Venturi

被引:0
|
作者
Hu, Chenjun [1 ]
Yu, Ling [1 ]
Wang, Dian [1 ]
He, Haitao [1 ]
Li, Yi [1 ]
机构
[1] Tsinghua Shenzhen Int Grad Sch, Shenzhen, Peoples R China
关键词
Gas-liquid flow; Venturi; Electrical tomography; Measurement technique;
D O I
10.1016/j.flowmeasinst.2024.102763
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Gas-liquid two-phase flow is characterized by complexity, non-homogeneity and difficulty in modeling. Therefore, traditional measurement methods often struggle to simultaneously meet the requirements of high precision and a wide measurement range. In this context, this study aims to explore an innovative multi- sensor fusion technique to achieve accurate measurement of gas-liquid two-phase flow under full operating conditions. In this study, a combination of three sensors, Venturi, ERT (Electrical Resistance Tomography) and ECT (Electrical Capacitance Tomography), is used to propose anew method based on the fusion of LVF (Liquid-phase Volume Fraction) calculations with flow results. Firstly, the high sensitivity characteristics of ECT and ERT sensors are utilized to obtain spatial distribution information of the flow, which is then used to calculate the LVF. Subsequently, the calculated LVF is combined with the total flow rate measured by the Venturi. Through an established mathematical model, the individual flow rates of the gas and liquid phases are inversely calculated. The results show that the method exhibits high measurement accuracy indifferent LVF ranges with the relative error controlled within 10%, especially in wet and non-wet gas conditions, which fills the gap of the traditional methods in this field. In addition, the method not only improves the measurement accuracy, but also broadens the measurement range, which meets the diversified needs of complex two-phase flow measurement in the oil and gas industry.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Gas-liquid two-phase flow measurement using ESM
    Dong, W
    Hu, LZ
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (6-7) : 827 - 832
  • [2] Study on Venturi nozzle for gas-liquid two-phase flow metering
    梁法春
    张修刚
    王栋
    林宗虎
    Journal of Harbin Institute of Technology(New series), 2012, (01) : 107 - 110
  • [3] Study on Venturi nozzle for gas-liquid two-phase flow metering
    梁法春
    张修刚
    王栋
    林宗虎
    Journal of Harbin Institute of Technology, 2012, 19 (01) : 107 - 110
  • [4] Investigation of pressurized gas-liquid two-phase flow with electrical capacitance tomography
    Liang, Shiguo
    Wang, Ruican
    Wang, Haigang
    Ye, Jiamin
    Yang, Wuqiang
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 1342 - 1347
  • [5] Extensible electrical capacitance tomography system for gas-liquid two-phase flow
    Xin, S.
    Wang, H.
    IET IMAGE PROCESSING, 2011, 5 (05) : 500 - 507
  • [6] Mass flow rate measurement of gas-liquid two-phase flow using acoustic-optical-Venturi mutisensors
    Li, Chaofan
    Zhu, Yan
    Wang, Jing
    Liu, Weiguang
    Fang, Lide
    Zhao, Ning
    FLOW MEASUREMENT AND INSTRUMENTATION, 2023, 90
  • [7] Gas-oil two-phase flow measurement using an electrical capacitance tomography system and a Venturi meter
    Huang, ZY
    Xie, DL
    Zhang, HJ
    Li, HQ
    FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (2-3) : 177 - 182
  • [8] Measurement parameters of gas-liquid two-phase flow by use the process tomography
    Rzasa, Mariusz R.
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (01): : 233 - 238
  • [9] Theory and experiment of ultrasonic process tomography for gas-liquid two-phase flow measurement
    Gu J.
    Tian C.
    Liu J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (07): : 146 - 154
  • [10] Measurement of Gas-Liquid Two-Phase Flow in Draft Tube
    Li, Jinfeng
    Chen, Wuguang
    Zhang, Zhengchuan
    Xu, Yongliang
    Li, Kaiying
    Yin, Junlian
    Wang, Dezhong
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2024, 58 (08): : 1188 - 1200