Gas-Liquid Two-Phase Flow Measurement With Throat-Extended Venturi Meter Based on Differential Pressure Ratios and Fluctuations

被引:0
|
作者
Suo, Peng [1 ,2 ]
Sun, Jiangtao [2 ]
Shi, Shiying [3 ]
Sun, Shijie [2 ]
He, Feng [4 ]
Zhang, Xiaokai [2 ]
Shen, Mengxian [2 ]
Li, Xiaolin [2 ]
Li, Jinfei [5 ]
Xu, Lijun [2 ]
机构
[1] Beihang Univ, Hangzhou Int Innovat Inst, Hangzhou 311115, Peoples R China
[2] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[3] Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China
[4] China Elect Technol Grp Corp, Res Inst 48, Changsha 410111, Peoples R China
[5] Dayanghuida Sci & Technol Co Ltd, Beijing 100048, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Differential pressure (DP) fluctuation; DP ratio (DPR); flow rate measurement; gas-liquid two-phase flow (GLTPF); throat-extended Venturi meter (TEVM); OIL;
D O I
10.1109/TIM.2024.3481576
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a novel approach to measuring gas-liquid two-phase flow (GLTPF) using a throat-extended Venturi meter (TEVM) based on differential pressure (DP) ratios and fluctuations. The over-reading (OR) and mass quality are the dominant parameters for accurate mass flow rate measurement by a TEVM. First, a liquid OR model is established based on multiple DP ratios (DPRs), gas-to-liquid density ratio (GLDR), and liquid densitometric Froude number. This model is solved by integrating a deep neural network (DNN) with an iterative optimization technique. Subsequently, a mass quality model is developed based on multi-DP fluctuations and other related parameters, which can also be solved using a DNN. Finally, the liquid and gas mass flow rates are obtained sequentially from the preceding results. The proposed method addresses the issue of significant errors in the direct solution of the conventional dual-parameter measurements. It utilizes both the static and dynamic features of multi-DP to achieve the simultaneous measurement of gas and liquid mass flow rates using a single TEVM. The experiment was conducted within a gas flow rate range of 1.3x10(-4)similar to 5.1x10(-3) kg/s, and a liquid flow rate range of 1.12 similar to 3.95 kg/s. The results demonstrate that the relative error for liquid and gas mass flow rates is within +/- 3% and +/- 10%, respectively. This indicates that the proposed method is a cost-effective and viable solution for GLTPF metering using a TEVM, and it can be further adapted to other experimental conditions.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] NEW GAS-LIQUID TWO-PHASE FLOW PATTERN MAPS BASED ON THE ENERGY RATIO OF PRESSURE FLUCTUATION THROUGH A VENTURI TUBE
    Sun, Zhiqiang
    Chen, Luyang
    Yao, Fengyan
    METROLOGY AND MEASUREMENT SYSTEMS, 2019, 26 (02) : 241 - 252
  • [32] The Development and Design of the Gas-Liquid Two-Phase Flow-meter System Based on DSP
    Zhu, Ji-Wei
    2008 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER THEORY AND ENGINEERING, 2008, : 978 - 981
  • [33] Flow measurement method of gas-liquid two-phase flow in gas producing well
    Zheng, Gui-Bo
    Jin, Ning-De
    Wang, Zhen-Ya
    Hu, Na-Na
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2008, 41 (08): : 919 - 925
  • [34] STATISTICAL PROPERTIES OF PRESSURE DROP FLUCTUATIONS AND FLOW PATTERNS IN HORIZONTAL GAS-LIQUID TWO-PHASE FLOW.
    Matsui, Goichi
    Aizawa, Toshihiko
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1987, 53 (485): : 144 - 148
  • [35] Gas-liquid two-phase flow measurement using differential pressure signals from a dual-cone flowmeter
    College of Metrological Technology & Engineering, China Jiliang University, Hangzhou
    310018, China
    Gao Xiao Hua Xue Gong Cheng Xue Bao, 1 (84-89):
  • [36] A new method for the flowrate measurement of gas-liquid two-phase flow
    Xie, Dailiang
    Li, Wenjun
    Wang, Fang
    Zheng, Hanguang
    Zheng, Yongjun
    Liang, Guowei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (04) : 1495 - 1500
  • [37] Multibubbles Segmentation and Characteristic Measurement in Gas-Liquid Two-Phase Flow
    Xue, Ting
    Chen, Yanlong
    Ge, Penghui
    ADVANCES IN MECHANICAL ENGINEERING, 2013,
  • [38] A new method for the flowrate measurement of gas-liquid two-phase flow
    Xie, Dailiang
    Li, Wenjun
    Wang, Fang
    Zheng, Hanguang
    Zheng, Yongjun
    Liang, Guowei
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 673 - +
  • [39] A New Method for the Velocity Measurement of Gas-Liquid Two-Phase Flow
    Zhou, Ying
    Huang, Zhiyao
    Wang, Baoliang
    Ji, Haifeng
    Li, Haiqing
    2013 IEEE SENSORS, 2013, : 1452 - 1455
  • [40] SVM based measurement method and implementation of gas-liquid two-phase flow for CMF
    Yue, Jing
    Xu, Ke-Jun
    Liu, Wen
    Zhang, Jian-Guo
    Fang, Zheng-Yu
    Zhang, Lun
    Xu, Hao-Ran
    MEASUREMENT, 2019, 145 : 160 - 171