Experimental Research on the Structural Performance of Shield Tunnel Segments Subjected to Different Fire Temperatures

被引:1
|
作者
Chen, Hongbin [1 ]
Jiang, Yujing [1 ]
Pan, Dongdong [2 ]
Sun, Huibin [3 ]
Zhang, Qian [4 ]
Yan, Peng [5 ,6 ]
机构
[1] Nagasaki Univ, Grad Sch Engn, Nagasaki 8528521, Japan
[2] Shandong Univ, Res Ctr Geotech & Struct Engn, Jinan 250061, Peoples R China
[3] Shandong Jianzhu Univ, Sch Transportat Engn, Jinan 250101, Peoples R China
[4] Shijiazhuang Tiedao Univ, Key Lab Struct Hlth Monitoring & Control, Shijiazhuang 050043, Peoples R China
[5] Shandong Univ Sci & Technol, State Key Lab Min Disaster Prevent & Control Cofou, Qingdao 266590, Peoples R China
[6] Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China
关键词
Shield tunnel segment; Different fire temperatures; Physical damage; Temperature distribution; Mechanical behavior; MAGNESIUM OXYSULFATE CEMENT; MECHANICAL-PROPERTIES; COMPOSITE BINDERS; WATER RESISTANCE; MICROSTRUCTURE; MGO-MGCL2-H2O; CARBONATION; STRENGTH; CONCRETE; FESO4;
D O I
10.1061/JMCEE7.MTENG-17685
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to determine the damaging effect of different fire temperatures on a segment, experimental research was carried out on the structural performance of segments subjected to different fire temperatures. A temperature plateau occurred when the temperature reached 100 degrees C. There were two temperature layers across the 300 mm thickness of the segment due to heating on one side only, and the temperature gradient within 0-50 mm was much more significant than that within 50-300 mm. The concrete spalling and the cracking initiated on the fired surface of the segment were severe; the maximum depth of concrete spalling on the fired surface of the segment at different fire temperatures was 600 degrees C: 15 mm; 800 degrees C: 45 mm; and 1,000 degrees C: 67 mm; further, the main reinforcement was exposed or even softened. Cracking was also initiated on the unfired surface, and even penetrating cracks developed on the side surface. The damage at both ends of the segment was more severe than that in the center. The fire temperatures were 600 degrees C, 800 degrees C, and 1,000 degrees C, the maximum midspan deflections were 5.27, 7.83, and 11.79 mm, the maximum midspan axial forces were 65.58, 208.41, and 333.63 kN, and the maximum reinforcement stresses were 22.49, 35.08, and 52.63 MPa, respectively. The mechanical parameters of the segment increased during the firing process and recovered during the cooling process, which is equivalent to a loading and unloading cycle for the segment. This study advances the understanding of the structural performance of shield tunnel segments subjected to different fire temperatures.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Semi-analytical thermo-mechanical model for the shield tunnel segmental joint subjected to elevated temperatures
    Shen, Yi
    Zhu, He-hua
    Yan, Zhi-guo
    Zhou, Long
    Lu, Yong
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 118
  • [42] Structural Fire Experimental Capabilities at the NIST National Fire Research Laboratory
    Bundy, Matthew
    Hamins, Anthony
    Gross, John
    Grosshandler, William
    Choe, Lisa
    FIRE TECHNOLOGY, 2016, 52 (04) : 959 - 966
  • [43] Structural Fire Experimental Capabilities at the NIST National Fire Research Laboratory
    Matthew Bundy
    Anthony Hamins
    John Gross
    William Grosshandler
    Lisa Choe
    Fire Technology, 2016, 52 : 959 - 966
  • [44] Numerical simulation research on excavation face stability of different depths of shield tunnel
    Sun X.
    Miao L.
    Lin H.
    Miao, Linchang (Lc.miao@seu.edu.cn), 1600, Southeast University (47): : 164 - 169
  • [45] Thermo-mechanical analysis of fire effects on the structural performance of shield tunnels
    Shen, Yi
    Zhu, Hehua
    Yan, Zhiguo
    Zhou, Long
    Zhang, Tong
    Men, Yanqing
    Lu, Yong
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 132
  • [46] Structural Performance of Reinforced Concrete Flat Plate Buildings Subjected to Fire
    George, Sara J.
    Tian, Ying
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2012, 6 (02) : 111 - 121
  • [47] Structural Performance of Reinforced Concrete Flat Plate Buildings Subjected to Fire
    Sara J. George
    Ying Tian
    International Journal of Concrete Structures and Materials, 2012, 6 : 111 - 121
  • [48] Experimental investigation on waterproofing performance of segmental joint with double gaskets for shield tunnel
    Ding, Wenqi
    Wang, Qiushi
    Qiao, Yafei
    Jin, Yuelang
    UNDERGROUND SPACE, 2022, 7 (05) : 898 - 910
  • [49] Experimental Study on the Diffusion Performance of Clay Shock Slurry in Shield Tunnel Construction
    Zhang, Zhiqiang
    Zhang, Kangjian
    Chen, Hao
    Journal of Railway Engineering Society, 2024, 41 (09) : 60 - 66
  • [50] AI-based evaluation method of mechanical performance of shield tunnel structures after fire
    Lu, Yaoliang
    Jiang, Jian
    Wang, Bo
    Chen, Wei
    Ye, Jihong