Experimental Research on the Structural Performance of Shield Tunnel Segments Subjected to Different Fire Temperatures

被引:1
|
作者
Chen, Hongbin [1 ]
Jiang, Yujing [1 ]
Pan, Dongdong [2 ]
Sun, Huibin [3 ]
Zhang, Qian [4 ]
Yan, Peng [5 ,6 ]
机构
[1] Nagasaki Univ, Grad Sch Engn, Nagasaki 8528521, Japan
[2] Shandong Univ, Res Ctr Geotech & Struct Engn, Jinan 250061, Peoples R China
[3] Shandong Jianzhu Univ, Sch Transportat Engn, Jinan 250101, Peoples R China
[4] Shijiazhuang Tiedao Univ, Key Lab Struct Hlth Monitoring & Control, Shijiazhuang 050043, Peoples R China
[5] Shandong Univ Sci & Technol, State Key Lab Min Disaster Prevent & Control Cofou, Qingdao 266590, Peoples R China
[6] Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China
关键词
Shield tunnel segment; Different fire temperatures; Physical damage; Temperature distribution; Mechanical behavior; MAGNESIUM OXYSULFATE CEMENT; MECHANICAL-PROPERTIES; COMPOSITE BINDERS; WATER RESISTANCE; MICROSTRUCTURE; MGO-MGCL2-H2O; CARBONATION; STRENGTH; CONCRETE; FESO4;
D O I
10.1061/JMCEE7.MTENG-17685
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to determine the damaging effect of different fire temperatures on a segment, experimental research was carried out on the structural performance of segments subjected to different fire temperatures. A temperature plateau occurred when the temperature reached 100 degrees C. There were two temperature layers across the 300 mm thickness of the segment due to heating on one side only, and the temperature gradient within 0-50 mm was much more significant than that within 50-300 mm. The concrete spalling and the cracking initiated on the fired surface of the segment were severe; the maximum depth of concrete spalling on the fired surface of the segment at different fire temperatures was 600 degrees C: 15 mm; 800 degrees C: 45 mm; and 1,000 degrees C: 67 mm; further, the main reinforcement was exposed or even softened. Cracking was also initiated on the unfired surface, and even penetrating cracks developed on the side surface. The damage at both ends of the segment was more severe than that in the center. The fire temperatures were 600 degrees C, 800 degrees C, and 1,000 degrees C, the maximum midspan deflections were 5.27, 7.83, and 11.79 mm, the maximum midspan axial forces were 65.58, 208.41, and 333.63 kN, and the maximum reinforcement stresses were 22.49, 35.08, and 52.63 MPa, respectively. The mechanical parameters of the segment increased during the firing process and recovered during the cooling process, which is equivalent to a loading and unloading cycle for the segment. This study advances the understanding of the structural performance of shield tunnel segments subjected to different fire temperatures.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Experimental Study on the Properties of Mixed-Fiber Concrete Shield Tunnel Segments Subjected to High Temperatures
    Zhang, Yajun
    Wang, Yao
    Ren, Zhaoqing
    FIRE-SWITZERLAND, 2023, 6 (01):
  • [2] Fire Experiments of Shield Tunnel Segments and Joints
    Ye J.-H.
    Li J.-J.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 35 (09): : 331 - 339
  • [3] Structural fire investigation and analysis on rectangular shield tunnel assembled by composite segments
    Yan, Zhiguo
    Zhou, Zihao
    Shen, Yi
    Li, Jiantao
    Guan, Linxing
    Zhu, Hehua
    ENGINEERING FAILURE ANALYSIS, 2024, 158
  • [4] Fire-induced structural response of shield tunnel segments under different boundary constraints and load levels
    Chen, Hongbin
    Jiang, Yujing
    Pan, Dongdong
    Zhang, Nan
    Wang, Bin
    Zhang, Sunhao
    Zhang, Jinge
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22
  • [5] Experimental study on mechanical behavior of splicing joints of shield tunnel lining subjected to fire
    Guo, Zhen
    Song, Jun
    Liu, Yi
    Wang, Xiangren
    Liu, Yibo
    Ma, Chuang
    Li, Fumin
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 (03): : 94 - 104
  • [6] Study on structure safety of shield tunnel subjected to fire load
    Wang Wei
    Xu Zhisheng
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 948 - 951
  • [7] Structural performance test on hybrid segments of the "double-O-tube" shield tunnel
    Watanabe, T
    Mizuguchi, K
    Waki, T
    Kohge, K
    Saito, E
    Sasaya, T
    Okumatsu, T
    MODERN TUNNELING SCIENCE AND TECHNOLOGY, VOLS I AND II, 2001, : 669 - 674
  • [8] Experimental investigation of reinforced concrete and hybrid fibre reinforced concrete shield tunnel segments subjected to elevated temperature
    Yan, Zhi-guo
    Shen, Yi
    Zhu, He-hua
    Li, Xiao-jun
    Lu, Yong
    FIRE SAFETY JOURNAL, 2015, 71 : 86 - 99
  • [9] STRUCTURAL PERFORMANCE OF A RAILWAY TUNNEL UNDER DIFFERENT FIRE SCENARIOS
    Khorasani, Negar Elhami
    Billittier, John
    Stavridis, Andreas
    PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2018, 2018,
  • [10] Mechanical behaviour of splicing joints in shield tunnel lining subjected to fire
    Yue, Yin
    Zhen, Guo
    Jun, Song
    Yi, Liu
    Xiang-ren, Wang
    Yi-bo, Liu
    Fu-min, Li
    Tunnelling and Underground Space Technology, 2022, 123