Implementation of Bioelectrical Impedance Measuring Instrument Based on Embedded System

被引:0
|
作者
Pawar C. [1 ,3 ]
Khan M. [2 ]
Saini J.P. [3 ]
Singh D. [4 ]
Bhardwaj M. [5 ]
Hu Y.-C. [6 ]
机构
[1] Department of Electronics and Communications Engineering, Netaji Subhash University of Technology, Delhi
[2] Electrical Department, Jamia Milia Islamia, New Delhi
[3] Netaji Subhash University of Technology, Delhi
[4] Department of Applied Mathematics, Allenhouse Institute of Technology, Kanpur
[5] Department of Computer Science and Engineering, KIET Group of Institutions, Delhi-NCR, Ghaziabad
[6] Department of Computer Science, Tunghai University, Taichung City
关键词
Statistics - User interfaces - Wireless local area networks (WLAN);
D O I
10.1155/2024/1024006
中图分类号
学科分类号
摘要
The present research aims to measure the segmental bioelectrical impedance (BI) of the human body at multifrequency, using a server user interface-based prototype, which provides subjects with measured data online anywhere accessed by their unique identifications. The present research measures the BI of the human leg and arm at a multifrequency range of 50-400 kHz with a developed and standard device. Recorded data can be transferred to the subject using Wi-Fi technology with their unique identifications and password. The system uses Wi-Fi interfacing for real-time data measurement and online data storage. The prototype can be used commercially. The compact size of the prototype becomes the demand of the common population. The pocket carry size makes it easy to carry anywhere for regular monitoring of the human body to prevent critical disease. The resultant data show that the mean and standard deviation of the left and right leg are 282.2 ± 14.29 and 274.80 ± 13.91 Ω, respectively. Similarly, in the case of the left arm and right arm, the mean and standard deviation are 325.41 ± 16.54 and 320.73 ± 16.07 Ω, respectively. The relative error between developed and standard devices is 3.53%. Results show that the left leg and arm impedance is always greater. However, the right leg and arm muscles are stronger than the left one, with less impedance at all frequencies. © 2024 Charu Pawar et al.
引用
收藏
相关论文
共 50 条
  • [41] Human Bioelectrical impedance Measuring Method Based on Principle of Multi-frequency and Multi-segment
    Gao, Xiue
    Tang, Jia
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENGINEERING 2011, 2011, 24 : 459 - 463
  • [42] Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor
    Santos, Jose
    Janeiro, Fernando M.
    Ramos, Pedro M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (10)
  • [43] Design and implementation of instrument cluster's management unit based on embedded Linux
    Fang Anping
    Ma Xiaoning
    Wang Zhen
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 254 - +
  • [44] Measuring Instrument of Impedance Characteristics of the Ultrasonic Vibrating Systems
    Khmelev, Vladimir N.
    Barsukov, Roman, V
    Genne, Dmitry, V
    Ilchenko, Evgeniy, V
    2018 19TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES (EDM 2018), 2018, : 347 - 349
  • [45] DESIGN OF A PROGRAMMABLE BIOELECTRICAL IMPEDANCE SYSTEM FOR BIOMEDICAL APPLICATIONS
    Loi, Daniela
    Marongiu, Gianfranco
    Palla, Claudia
    Angius, Gianmarco
    Gallamini, Michele
    BIODEVICES: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2012, : 307 - 310
  • [46] Functional abstract and design of bioelectrical impedance measurement system
    Wang, Chao
    Zhang, Qiang
    Huang, Chunyan
    Wang, Huaxiang
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2008, 29 (01): : 38 - 42
  • [47] Design and Implementation of Vehicle Bluetooth system based on Embedded System
    Qiu Bo
    Lv Changwu
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, CHEMISTRY AND COMPUTER ENGINEERING (ICMMCCE 2017), 2017, 141 : 74 - 78
  • [48] An Instrument for Measuring the Degree of Lean Implementation in Manufacturing
    Herzog, Natasa Vujica
    Tonchia, Stefano
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2014, 60 (12): : 797 - 803
  • [49] Feasibility Study on the Bioelectrical Impedance Analysis down to Low Frequencies using an Electrochemical Instrument
    Sekine K.
    IEEJ Transactions on Electronics, Information and Systems, 2022, 142 (12) : 1295 - 1299
  • [50] Design and Implementation of Automated Rotatory Probe Embedded System for Measuring Axial Ratio
    Patel, Hrishikesl
    Seth, Gaurav
    Trivedi, Sanjay
    2019 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (AP-RASC), 2019,