Signal Acquisition and Algorithm Design for Bioimpedance-Based Heart Rate Estimation from the Wrist

被引:0
|
作者
Lapsa, Didzis [1 ,2 ]
Metshein, Margus [3 ]
Krivosei, Andrei [3 ]
Janeliukstis, Rims [1 ]
Martens, Olev [3 ]
Elsts, Atis [1 ]
机构
[1] Inst Elect & Comp Sci, Dzerbenes St 14, LV-1006 Riga, Latvia
[2] Univ Latvia, Fac Comp, Raina Bulvaris 19, LV-1586 Riga, Latvia
[3] Tallinn Univ Technol, Thomas Johann Seebeck Dept Elect, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 21期
关键词
bipolar electrode system; electrical bioimpedance; heart rate estimation; peak detection; signal-to-noise ratio; tetrapolar electrode system;
D O I
10.3390/app14219632
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: Heart rate (HR) is a critical biomarker that provides insights into overall health, stress levels, and the autonomic nervous system. Pulse wave signals contain valuable information about the cardiovascular system and heart status. However, signal acquisition in wearables poses challenges, particularly when using electrical sensors, due to factors like the distance from the heart, body movement, and suboptimal electrode placement. Methods: Electrical bioimpedance (EBI) measurements using bipolar and tetrapolar electrode systems were employed for pulse wave signal acquisition from the wrist in both perpendicular and distal configurations. Signal preprocessing techniques, including baseline removal via Hankel matrix methods, normalization, cross-correlation, and peak detection, were applied to improve signal quality. This study describes the combination of sensor-level signal acquisition and processing for accurate wearable HR estimation. Results: The bipolar system was shown to produce larger Delta Z(t), while the tetrapolar system demonstrated higher sensitivity. Distal placement of the electrodes yielded greater Delta Z(t) (up to 0.231 Omega) when targeting both wrist arteries. Bandpass filtering resulted in a better signal-to-noise ratio (SNR), achieving 3.6 dB for the best bipolar setup and 4.8 dB for the tetrapolar setup, compared to 2.6 and 3.3 dB SNR, respectively, with the Savitzky-Golay filter. The custom HR estimation algorithm presented in this paper demonstrated improved accuracy over a reference method, achieving an average error of 1.8 beats per minute for the best bipolar setup, with a mean absolute percentage error (MAPE) of 8%. Conclusions: The analysis supports the feasibility of using bipolar electrode setups on the wrist and highlights the importance of electrode positioning relative to the arteries. The proposed signal processing method, featuring a preprocessing pipeline and HR estimation algorithm, provides a proof-of-concept demonstration for HR estimation from EBI signals acquired at the wrist.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] A Correlation-Based Algorithm for Beat-to-Beat Heart Rate Estimation from Ballistocardiograms
    Wen, Xin
    Huang, Yanqi
    Wu, Xiaomei
    Zhang, Biyong
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6355 - 6358
  • [32] Computerized Algorithm for Fetal Heart Rate Baseline and Baseline Variability Estimation based on Distance Between Signal Average and α Value
    Nidhal, Shahad
    Ali, M. A. Mohd
    Zaidan, A. A.
    Zaidan, B. B.
    Najah, Hind
    INTERNATIONAL JOURNAL OF PHARMACOLOGY, 2011, 7 (02) : 228 - 237
  • [33] Heart rate estimation from wrist-type photoplethysmography signals during physical exercise
    Arunkumar, K. R.
    Bhaskar, M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [34] Fast GNSS signal acquisition with Doppler frequency estimation algorithm
    Gao, Faqin
    Xia, Haixia
    GPS SOLUTIONS, 2018, 22 (04)
  • [35] Fast GNSS signal acquisition with Doppler frequency estimation algorithm
    Faqin Gao
    Haixia Xia
    GPS Solutions, 2018, 22
  • [36] Non-contact respiratory rate and heart rate signal acquisition system
    Guo J.
    Chen Y.-H.
    Wang L.-R.
    Wei Y.
    Guo Y.
    Zhao Y.-M.
    Liu L.-L.
    Chen X.-H.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1354 - 1361
  • [37] Approximation-based transformation of color signal for heart rate estimation with a webcam
    Kopeliovich, Mikhail
    Petrushan, Mikhail
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE (ICPRAI 2018), 2018, : 638 - 642
  • [38] Approximation-Based Transformation of Color Signal for Heart Rate Estimation with a Webcam
    Kopeliovich M.
    Petrushan M.
    Shaposhnikov D.
    Pattern Recognition and Image Analysis, 2018, 28 (4) : 646 - 651
  • [39] A successive cancellation algorithm for fetal heart-rate estimation using an intrauterine ECG signal
    Lai, KC
    Shynk, JJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) : 943 - 954
  • [40] Estimation of Heart Rate and Respiratory Rate from Photoplethysmography Signal for the Detection of Obstructive Sleep Apnea
    Jothi, E. Smily Jeya
    Anitha, J.
    ARTIFICIAL INTELLIGENCE AND APPLIED MATHEMATICS IN ENGINEERING PROBLEMS, 2020, 43 : 429 - 436