Signal Acquisition and Algorithm Design for Bioimpedance-Based Heart Rate Estimation from the Wrist

被引:0
|
作者
Lapsa, Didzis [1 ,2 ]
Metshein, Margus [3 ]
Krivosei, Andrei [3 ]
Janeliukstis, Rims [1 ]
Martens, Olev [3 ]
Elsts, Atis [1 ]
机构
[1] Inst Elect & Comp Sci, Dzerbenes St 14, LV-1006 Riga, Latvia
[2] Univ Latvia, Fac Comp, Raina Bulvaris 19, LV-1586 Riga, Latvia
[3] Tallinn Univ Technol, Thomas Johann Seebeck Dept Elect, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 21期
关键词
bipolar electrode system; electrical bioimpedance; heart rate estimation; peak detection; signal-to-noise ratio; tetrapolar electrode system;
D O I
10.3390/app14219632
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: Heart rate (HR) is a critical biomarker that provides insights into overall health, stress levels, and the autonomic nervous system. Pulse wave signals contain valuable information about the cardiovascular system and heart status. However, signal acquisition in wearables poses challenges, particularly when using electrical sensors, due to factors like the distance from the heart, body movement, and suboptimal electrode placement. Methods: Electrical bioimpedance (EBI) measurements using bipolar and tetrapolar electrode systems were employed for pulse wave signal acquisition from the wrist in both perpendicular and distal configurations. Signal preprocessing techniques, including baseline removal via Hankel matrix methods, normalization, cross-correlation, and peak detection, were applied to improve signal quality. This study describes the combination of sensor-level signal acquisition and processing for accurate wearable HR estimation. Results: The bipolar system was shown to produce larger Delta Z(t), while the tetrapolar system demonstrated higher sensitivity. Distal placement of the electrodes yielded greater Delta Z(t) (up to 0.231 Omega) when targeting both wrist arteries. Bandpass filtering resulted in a better signal-to-noise ratio (SNR), achieving 3.6 dB for the best bipolar setup and 4.8 dB for the tetrapolar setup, compared to 2.6 and 3.3 dB SNR, respectively, with the Savitzky-Golay filter. The custom HR estimation algorithm presented in this paper demonstrated improved accuracy over a reference method, achieving an average error of 1.8 beats per minute for the best bipolar setup, with a mean absolute percentage error (MAPE) of 8%. Conclusions: The analysis supports the feasibility of using bipolar electrode setups on the wrist and highlights the importance of electrode positioning relative to the arteries. The proposed signal processing method, featuring a preprocessing pipeline and HR estimation algorithm, provides a proof-of-concept demonstration for HR estimation from EBI signals acquired at the wrist.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] PARAMETRIC MODELING OF HUMAN WRIST FOR BIOIMPEDANCE-BASED PHYSIOLOGICAL SENSING
    Sel, Kaan
    Huerta, Noah
    Sacks, Michael S.
    Jafari, Roozbeh
    2022 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2022, : 1161 - 1165
  • [2] A Weiner Filter Based Robust Algorithm For Estimation Of Heart Rate From Wrist Based Photoplethysmogram
    Ahmed, Nasimuddin
    Sharma, Varsha
    Chowdhury, Arijit
    Mukhopadhyay, Shalini
    Ghose, Avik
    UBICOMP/ISWC'19 ADJUNCT: PROCEEDINGS OF THE 2019 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING AND PROCEEDINGS OF THE 2019 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, 2019, : 1150 - 1153
  • [3] PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring-A Comprehensive Review
    Lapsa, Didzis
    Janeliukstis, Rims
    Metshein, Margus
    Selavo, Leo
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [4] DOES PERITONEAL DIALYSIS AFFECT BIOIMPEDANCE-BASED VOLUME ESTIMATION?
    Schneditz, Daniel
    Puetuen, Ezgi
    Sauseng, Notburga
    Ribitsch, Werner
    Rosenkranz, Alexander R.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [5] Heart Rate Estimation Algorithm From Wrist-based Photoplethysmogram Using Subspace Learning Method
    Ahmed, Nasimuddin
    Mukhopadhyay, Shalini
    Sharma, Varsha
    Ghose, Avik
    2019 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS (PERCOM WORKSHOPS), 2019, : 145 - 150
  • [6] Heart Rate Estimation from Wrist PPG Signal During Intense Physical Exercise
    Hasan K.
    Chowdhury M.H.
    Pathan N.S.
    Hossain Q.D.
    SN Computer Science, 4 (5)
  • [7] Measurement Frequency Evaluation for Bioimpedance-Based Blood-Glucose Estimation
    Takamatsu, Reo
    Higuchi, Kenichi
    Muramatsu, Dairoku
    2021 IEEE 3RD GLOBAL CONFERENCE ON LIFE SCIENCES AND TECHNOLOGIES (IEEE LIFETECH 2021), 2021, : 309 - 310
  • [8] Bioimpedance-based measurement method for simultaneous acquisition of respiratory and cardiac gating signals
    Koivumaki, T.
    Vauhkonen, M.
    Kuikka, J. T.
    Hakulinen, M. A.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (08) : 1323 - 1334
  • [9] Bioimpedance-based edema index as a promising indicator of hypervolemia in heart failure
    Park, Y. Yoonjee
    Lee, J.
    Jang, Y.
    Kang, D. O.
    Jang, W. Y.
    Choi, J. Y.
    Kim, W. H.
    Roh, S. Y.
    Na, J. O.
    Choi, C. U.
    Kim, J. W.
    Rha, S. W.
    Park, C. G.
    Seo, H. S.
    Kim, E. J.
    EUROPEAN JOURNAL OF HEART FAILURE, 2020, 22 : 188 - 188
  • [10] Diagnostic test of bioimpedance-based neural network algorithm in early cervical cancer
    Mei, Ling
    Meng, Jian
    Wei, Dongmei
    Hu, Qian
    Chen, Yueyue
    Cui, Tao
    Zhang, Yueting
    Li, Qiao
    Zhang, Xiaoli
    Liu, Yuqing
    Wang, Qian
    Ding, Lisha
    Wang, Tao
    Feng, Yukuan
    Lei, Wei
    Deng, Yanhui
    Gong, Xiaoyun
    Ling, Jingchun
    Niu, Xiaoyu
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (08)