Impacts of Increasing Temperature and Relative Humidity in Air-Cooled Tropical Data Centers

被引:0
|
作者
Van Le, Duc [1 ]
Zhou, Jing [2 ]
Wang, Rongrong [1 ]
Tan, Rui [1 ]
Duan, Fei [2 ]
机构
[1] Nanyang Technol Univ, Sch Comp Sci & Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
基金
新加坡国家研究基金会;
关键词
Cooling; Servers; Temperature measurement; Reliability; Temperature distribution; Costs; Green computing; Data centers; temperature; humidity; energy usage; total cost of ownership analysis; DESIGN;
D O I
10.1109/TSUSC.2024.3379550
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Data centers (DCs) are power-intensive facilities which use a significant amount of energy for cooling the servers. Increasing the temperature and relative humidity (RH) setpoints is a rule-of-thumb approach to reducing the DC energy usage. However, the high temperature and RH may undermine the server's reliability. Before we can choose the proper temperature and RH settings, it is essential to understand how the temperature and RH setpoints affect the DC power usage and server's reliability. To this end, we constructed and experimented with an air-cooled DC testbed in Singapore, which consists of a direct expansion cooling system and 521 servers running real-world application workloads. This paper presents the key measurement results and observations from our 11-month experiments. Our results suggest that by operating at a supply air temperature setpoints of 29(degrees)C, our testbed achieves substantial cooling power saving with little impact on the server's reliability. Furthermore, we present a total cost of ownership (TCO) analysis framework which guides settings of the temperature and RH for a DC. Our observations and TCO analysis framework will be useful to future efforts in building and operating air-cooled DCs in tropics and beyond.
引用
收藏
页码:790 / 802
页数:13
相关论文
共 50 条
  • [1] The Impact of Barometric Pressure, Temperature, and Operating Temperature Difference on Air-Cooled Data Centers
    Dunnavant, Keith
    ASHRAE TRANSACTIONS 2013, VOL 119, PT 1, 2013, 119 : 176 - 187
  • [2] ENERGY MODELING OF AIR-COOLED DATA CENTERS: PART II THE EFFECT OF RECIRCULATION ON THE ENERGY OPTIMIZATION OF OPEN-AISLE, AIR-COOLED DATA CENTERS
    Demetriou, Dustin W.
    Khalifa, H. Ezzat
    PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 395 - 404
  • [3] EFFECTIVENESS OF AN AIR-COOLED VEST USING SELECTED AIR-TEMPERATURE AND HUMIDITY COMBINATIONS
    PIMENTAL, NA
    COSIMINI, HM
    SAWKA, MN
    WENGER, CB
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1987, 58 (02): : 119 - 124
  • [4] Evaluation of the cooling effectiveness of air-cooled data centers by energy diagram
    Li, Nan
    Li, Haowei
    Duan, Kaiwen
    Tao, Wen-Quan
    APPLIED ENERGY, 2025, 382
  • [5] Thermal management in legacy air-cooled data centers: An overview and perspectives
    Isazadeh, Amin
    Ziviani, Davide
    Claridge, David E.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 187
  • [6] Wireless Sensor Network for Continuous Temperature Monitoring in Air-Cooled Data Centers: Applications and Measurement Results
    Scherer, Thomas
    Lombriser, Clemens
    Schott, Wolfgang
    Hong Linh Truong
    Weiss, Beat
    AD-HOC, MOBILE, AND WIRELESS NETWORKS, 2012, 7363 : 235 - 248
  • [7] Cooling architecture selection for air-cooled Data Centers by minimizing exergy destruction
    Gupta, Rohit
    Asgari, Sahar
    Moazamigoodarzi, Hosein
    Pal, Souvik
    Puri, Ishwar K.
    ENERGY, 2020, 201
  • [8] Workload management for air-cooled data centers: An energy and exergy based approach
    Gupta, Rohit
    Moazamigoodarzi, Hosein
    MirhoseiniNejad, SeyedMorteza
    Down, Douglas G.
    Puri, Ishwar K.
    ENERGY, 2020, 209
  • [9] Development of an Outdoor Air Cooling-Type Air-Cooled Package Air Conditioner for Data Centers
    Udagawa, Yosuke
    Sekiguchi, Keisuke
    Yanagi, Masahide
    Uekusa, Tsuneo
    Naito, Yasuhiro
    ASHRAE TRANSACTIONS 2013, VOL 119, PT 1, 2013, 119 : 167 - 175
  • [10] A parametric CFD study of computer room air handling bypass in air-cooled data centers
    Ahmadi, Vahid Ebrahimpour
    Erden, Hamza Salih
    APPLIED THERMAL ENGINEERING, 2020, 166