Flexible regulation of airport air-conditioning systems: Impact of cooling load variations on temperature stability

被引:0
|
作者
Lin, Lin [1 ,2 ]
Chen, Guodong [1 ]
Wang, Weian [1 ]
Liu, Xiaochen [2 ]
Liu, Xiaohua [2 ]
Zhang, Tao [2 ]
机构
[1] Shanghai Elect Grp Power Transmiss & Distribut Equ, Shanghai 200042, Peoples R China
[2] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
来源
关键词
Flexible regulation; Cooling load variations; Air-conditioning systems; Indoor temperature stability; Renewable energy; DEMAND RESPONSE; FLEXIBILITY; BUILDINGS;
D O I
10.1016/j.jobe.2024.111324
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The integration of renewable energy sources has led to notable supply-demand imbalances due to their intermittent nature. Air-conditioning systems, as significant energy consumers with considerable flexibility, play a crucial role in integrating renewable energy and regulating power systems. This paper delves into the capability of air-conditioning systems in airports to flexibly adjust, particularly examining how varying cooling loads impact indoor temperatures. The energy flexibility of the air-conditioning system is evaluated based on three fundamental cooling load variations (incremental, translational, and discrete), and several evaluation parameters are defined. For areas with smaller cooling load fluctuations, there is a greater adjustment margin, but long adjustment periods should be avoided. For areas with larger fluctuations, the original cooling load curve should be considered in the adjustment strategy. The simulation results show that advancing or delaying the supply by 1 h during peak cooling load periods can ensure indoor temperature stability, and step-type cooling load curves do not adversely affect indoor comfort levels. Practical case studies further demonstrate that utilizing water storage as an active regulation strategy can reduce operational costs by 26 %, and with flexible adjustments, this reduction can increase to 35-54 %. The study offers a framework to optimize air-conditioning flexibility in airports, facilitating better renewable energy integration and grid stability, which holds significant potential to reduce costs and improve energy efficiency, thus contributing to sustainable energy management.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Load forecast and fuzzy control of the air-conditioning systems at the subway stations
    Bi, Haiquan
    Zhou, Yuanlong
    Liu, Jin
    Wang, Honglin
    Yu, Tao
    Journal of Building Engineering, 2022, 49
  • [22] PARTIAL LOAD OPERATION - COMPRESSOR CAPACITY CONTROL FOR AIR-CONDITIONING SYSTEMS
    GARLAND, MW
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1980, 22 (04): : 37 - 39
  • [23] Load forecast and fuzzy control of the air-conditioning systems at the subway stations
    Bi, Haiquan
    Zhou, Yuanlong
    Liu, Jin
    Wang, Honglin
    Yu, Tao
    JOURNAL OF BUILDING ENGINEERING, 2022, 49
  • [24] Vertical Temperature Profiles and Cooling Load in Large Spaces Ventilated by Stratified Air-Conditioning Systems: Scale-Model Experiment and Nodal Modeling
    Xu, Yukun
    Wang, Xin
    Shi, Chenlu
    Huai, Xiaoqiang
    Wang, Fei
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (05)
  • [25] Formation analysis of cooling load from envelopes under air-conditioning intermittent operation
    Guan, Yifan
    Hu, Chenxi
    Meng, Xi
    SOLAR ENERGY, 2025, 292
  • [26] Predictive model of cooling load for ice storage air-conditioning system by using GBDT
    Zhang, Wanhu
    Yu, Junqi
    Zhao, Anjun
    Zhou, Xinwei
    ENERGY REPORTS, 2021, 7 : 1588 - 1597
  • [27] Development of a cooling load prediction model for air-conditioning system control of office buildings
    Fan, Chengliang
    Liao, Yundan
    Ding, Yunfei
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2019, 14 (01) : 70 - 75
  • [28] Switching Optimal Controller For Evaporation Temperature And Superheat Of Air-Conditioning Cooling System
    Zheng, Linlin
    Li, Shujiang
    Wang, Xiangdong
    PROCEEDINGS OF THE 2017 2ND JOINT INTERNATIONAL INFORMATION TECHNOLOGY, MECHANICAL AND ELECTRONIC ENGINEERING CONFERENCE (JIMEC 2017), 2017, 62 : 378 - 382
  • [29] Solar hybrid air-conditioning system for high temperature cooling in subtropical city
    Fong, K. F.
    Lee, C. K.
    Chow, T. T.
    Lin, Z.
    Chan, L. S.
    RENEWABLE ENERGY, 2010, 35 (11) : 2439 - 2451
  • [30] Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China
    Lin, H.
    Xu, B.
    Chen, Y.
    Wang, W.
    JOURNAL OF APPLIED MICROBIOLOGY, 2009, 106 (02) : 606 - 612