Study of breakdown factors of XLPE cables

被引:0
|
作者
Katakai S. [1 ]
Murata Y. [1 ]
Yamazaki T. [1 ]
机构
[1] Technology Development Department, Electric Wire and Cable Energy Business Unit, Sumitomo Electric Industries ltd., 5-1-1, Hitaka-cho, Hitachi
关键词
Breakdown; Defect; Peroxide decomposition products; Temperature dependence; Treeing; XLPE cable;
D O I
10.1541/ieejfms.138.521
中图分类号
学科分类号
摘要
Breakdown factors of XLPE cables are studied, using model cables and block XLPE samples. The influences of defects and peroxide decomposition products on breakdown strength and tree inception stress are evaluated. The breakdown strength of XLPE cables is greatly affected by the existence of defects. In addition, AC breakdown strength is increased by the effect of peroxide decomposition products, especially in cases where the size of the defects is small. The effect is caused by the concentration of decomposition products around defects due to dielectrophoresis, because decomposition products have high permittivity and low resistivity. Stress relaxation and an apparent increase of tip radius occurs. These effects are weakened at high temperature. © 2018 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:521 / 530
页数:9
相关论文
共 50 条
  • [41] Effects of Testing on Service Aged XLPE Cables
    Abdolall, K.
    Vandermaar, A. J.
    Stephens, M.
    Tarampi, Dexter
    2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2015, : 93 - 97
  • [42] Causes of deterioration in xlpe mv cables: A review
    Oluwafemi I.
    Salau A.O.
    Laseinde T.
    Recent Patents on Engineering, 2021, 15 (02) : 218 - 224
  • [43] Development of external diagnosis for terminals in XLPE cables
    Morishita, Yukinobu
    Miyajima, Kazuhisa
    Kamibayashi, Tomonori
    Nagayama, Tadanori
    Saito, Tugio
    Abe, Kazutoshi
    Suzuki, Hiroshi
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1158 - +
  • [44] Development of external diagnosis for terminals in XLPE cables
    Suzuki, H. (suzuki.hirosi@jpowers.co.jp), 1600, Institute of Electrical Engineers of Japan (133):
  • [45] Health condition assessment of MV XLPE and bare cables. Case study
    Rosero, Laura
    Cardenas, Luis A.
    Garzon, Camilo
    Teran, Daniel
    Nova, David
    Herrera, Fernando
    Diaz, Jennifer
    Valbuena, Ivan
    Garcia, Rodolfo
    IFAC PAPERSONLINE, 2023, 56 (02): : 6618 - 6623
  • [46] DEVELOPMENT AND RELIABILITY STUDY ON HIGH VOLTAGE RCP-XLPE CABLES.
    Yamada, Y.
    Matsubara, H.
    Fukunaga, S.
    Yatsuka, K.
    Proceedings of the Technical Programme - INTERNEPCON: International Electronic Packaging and Production Conferences, 1979, : 386 - 390
  • [47] PD detection of XLPE cables accessories on UHF
    Zheng, B
    Wang, W
    Li, CR
    Li, CY
    Zhang, LH
    2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 438 - 440
  • [48] Quantifying degradation of XLPE insulated distribution cables
    Dalal, SB
    Gorur, RS
    Dyer, ML
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1841 - 1845
  • [49] Insulating material cleanliness in the production of XLPE cables
    Prunk, Harry
    Wire Industry, 1997, 64 (762):
  • [50] Study on insulation diagnosis for XLPE cables using dumping oscillating high voltage
    Takahashi, Toshihiro
    Takahashi, Tsuguhiro
    Okamoto, Tatsuki
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1254 - 1257