Study of breakdown factors of XLPE cables

被引:0
|
作者
Katakai S. [1 ]
Murata Y. [1 ]
Yamazaki T. [1 ]
机构
[1] Technology Development Department, Electric Wire and Cable Energy Business Unit, Sumitomo Electric Industries ltd., 5-1-1, Hitaka-cho, Hitachi
关键词
Breakdown; Defect; Peroxide decomposition products; Temperature dependence; Treeing; XLPE cable;
D O I
10.1541/ieejfms.138.521
中图分类号
学科分类号
摘要
Breakdown factors of XLPE cables are studied, using model cables and block XLPE samples. The influences of defects and peroxide decomposition products on breakdown strength and tree inception stress are evaluated. The breakdown strength of XLPE cables is greatly affected by the existence of defects. In addition, AC breakdown strength is increased by the effect of peroxide decomposition products, especially in cases where the size of the defects is small. The effect is caused by the concentration of decomposition products around defects due to dielectrophoresis, because decomposition products have high permittivity and low resistivity. Stress relaxation and an apparent increase of tip radius occurs. These effects are weakened at high temperature. © 2018 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:521 / 530
页数:9
相关论文
共 50 条
  • [31] Study of siloxane injection technology on XLPE cables for water tree aging
    Zhou, Kai
    Zhao, Wei
    Guan, Shungang
    Yuan, Lin
    Tao, Wenbiao
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2013, 28 (01): : 29 - 35
  • [32] Study of treeing phenomena in the development of insulation for 500 kV XLPE cables
    Ishibashi, A
    Kawai, T
    Nakagawa, S
    Muto, H
    Katakai, S
    Hirotsu, K
    Nakatsuka, T
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1998, 5 (05) : 695 - 706
  • [33] ELECTRICAL BREAKDOWN CHARACTERISTICS AND TESTING OF HIGH-VOLTAGE XLPE AND ELECTRON-PARAMAGNETIC-RES INSULATED CABLES
    BAHDER, G
    SOSNOWSKI, M
    KATZ, C
    EATON, R
    KLEIN, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (07): : 2173 - 2185
  • [34] Correlation between AC breakdown strength and low frequency dielectric loss of water tree aged XLPE cables
    Norwegian Univ of Science and, Technology , Trondheim, Norway
    IEEE Trans Power Delivery, 1 (40-45):
  • [35] Correlation between AC breakdown strength and low frequency dielectric loss of water tree aged XLPE cables
    Hvidsten, S
    Ildstad, E
    Holmgren, B
    Werelius, P
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (01) : 40 - 45
  • [36] Dielectric breakdown strength correlation with time-to-failure during wet aging of XLPE-insulated cables
    Walton, MD
    Bernstein, BS
    Thue, WA
    Smith, JT
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) : 750 - 755
  • [37] Investigations on the failure modes of XLPE cables and joints
    Nagamani, HN
    Channakeshava
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) : 706 - 711
  • [38] Development of 500-kV XLPE cables
    Kaminaga, K
    Ichihara, M
    Jinno, M
    Tanabe, T
    Fukunaga, S
    Kanaoka, M
    Takehana, H
    ELECTRICAL ENGINEERING IN JAPAN, 1997, 118 (01) : 28 - 40
  • [39] Development of External Diagnosis for Terminal in XLPE Cables
    Onoda, H.
    Morishita, Y.
    Watanabe, M.
    Nagayama, T.
    Suzuki, H.
    Abe, K.
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 294 - +
  • [40] Experience in PD site location in XLPE cables
    Fawcett, T
    Hilder, D
    Johnson, K
    Larzelere, B
    IEEE ELECTRICAL INSULATION MAGAZINE, 2000, 16 (05) : 8 - 12