Modelling of heat and mass transfer in a two-phase closed thermosyphon

被引:1
|
作者
Lataoui, Zied [1 ]
Benselama, Adel M. [2 ]
机构
[1] Univ Monastir, Ecole Natl Ingenieurs Monastir, Lab Etud Syst Therm & Energet, Ave Ibn El Jazzar, Monastir 5019, Tunisia
[2] Univ Poitiers, CNRS ENSMA, Inst Pprime FTC COST, 1 Ave Clement Ader, F-86961 Futuroscope, France
关键词
Thermosyphon; Two-phase flow; Volume of fluid; Phase change; Heat transfer performance; INCLINATION ANGLE; FILL RATIO; THERMAL PERFORMANCE; SOLAR COLLECTORS; PIPE; WATER; CONDENSATION; SIMULATION; PARAMETERS;
D O I
10.1016/j.energy.2024.133851
中图分类号
O414.1 [热力学];
学科分类号
摘要
A CFD model is developed to simulate the heat and mass transfer inside a two-phase closed thermosyphon. Based on the "volume of fluid" method, governing equations are solved using the OpenFOAM utilities. The involved complex phenomena like evaporation and condensation occurring in such a device and associated with twophase flow are investigated. A noticeable novelty of this model is that neither artificial, ad hoc nor specific nucleation means is needed to trigger evaporation along the heat source walls; an altogether unique phase change model is valid and uniformly used within the flow occurring inside the thermosyphon. The numerical results are compared to well-documented experimental data showing very good agreement: maximum deviation of 1 % and 2.7 % are obtained for mean temperature and condenser pressure, respectively. The axial thermal resistance values are also compared with the experimental data. Fair agreement was obtained in the overall equivalent resistance (26.4-32.5 %) and in the evaporator axial resistance (25-27.5 %). In addition, the evaporator slug flow pattern is successfully captured by the model. The liquid fraction distribution inside the thermosyphon is analyzed as time evolves. It shows, in particular, that bubble activation and growth have the same trend as previous experimental visualization results, namely denser activation close to the meniscus. The velocity distribution shows also recirculation in the top of the condenser zones and above the liquid meniscus in the evaporator zone, too, as a direct effect of buoyancy and natural convection. As activated bubbles rise and coalesce into larger bubbles, the occurrence of a slug flow is observed. Furthermore, the tested model had shown its efficiency to predict the main fluid flow and thermal characteristics of a thermosyphon when pseudo-steady state is reached.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] EXPERIMENTAL STUDY ON HEAT TRANSFER CHARACTERISTICS OF A MODIFIED TWO-PHASE CLOSED THERMOSYPHON
    Aghel, Babak
    Rahmi, Masoud
    Almasi, Saeed
    THERMAL SCIENCE, 2017, 21 (06): : 2481 - 2489
  • [22] Heat transfer characteristics in a condenser of closed two-phase thermosyphon: Effect of entrainment on heat transfer deterioration
    Hashimoto, Hiroyuki
    Kaminaga, Fumito
    Heat Transfer - Asian Research, 2002, 31 (03): : 212 - 225
  • [23] Numerical modelling of the temperature distribution in a two-phase closed thermosyphon
    Fadhl, Bandar
    Wrobel, Luiz C.
    Jouhara, Hussam
    APPLIED THERMAL ENGINEERING, 2013, 60 (1-2) : 122 - 131
  • [24] Heat transfer characteristics of a two-phase closed thermosyphon using different working fluids
    Behrooz Mirzaei Ziapour
    Hadi Shaker
    Heat and Mass Transfer, 2010, 46 : 307 - 314
  • [25] Modelling of two-phase closed thermosyphon based on SINDA/FLUINT
    Ma, Limin
    Yin, Xiaoying
    Shang, Linlin
    Ji, Zhongli
    APPLIED THERMAL ENGINEERING, 2018, 130 : 375 - 383
  • [26] DESIGN AND EXPERIMENTAL ANALYSIS OF HEAT TRANSFER PERFORMANCE OF A TWO-PHASE CLOSED THERMOSYPHON SYSTEM
    Elmosbahi, M. S.
    Hamdi, M.
    Hazami, M.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2023, 64 (05) : 858 - 870
  • [27] Heat transfer performance of an anodized two-phase closed thermosyphon with refrigerant as working fluid
    Solomon, A. Brusly
    Roshan, R.
    Vincent, Walter
    Karthikeyan, V. K.
    Asirvatharn, L. Godson
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 82 : 521 - 529
  • [28] Heat transfer characteristics of a two-phase closed thermosyphon using different working fluids
    Ziapour, Behrooz Mirzaei
    Shaker, Hadi
    HEAT AND MASS TRANSFER, 2010, 46 (03) : 307 - 314
  • [29] DESIGN AND EXPERIMENTAL ANALYSIS OF HEAT TRANSFER PERFORMANCE OF A TWO-PHASE CLOSED THERMOSYPHON SYSTEM
    M. S. Elmosbahi
    M. Hamdi
    M. Hazami
    Journal of Applied Mechanics and Technical Physics, 2023, 64 : 858 - 870
  • [30] Heat transfer performance of two-phase closed thermosyphon with oxidized CNT/water nanofluids
    Saeed Zeinali Heris
    Marjan Fallahi
    Mehdi Shanbedi
    Ahmad Amiri
    Heat and Mass Transfer, 2016, 52 : 85 - 93