Research on Calibration Method of Flexible Blood Pressure Sensor Based on Photoplethysmography

被引:0
|
作者
Shi, Wei [1 ,2 ]
Dong, Lin-Xi [1 ,2 ]
Weng, Bin-Hui [1 ,2 ]
Cheng, Jia-Gen [1 ,2 ]
Yang, Wei-Huang [1 ,2 ]
Liu, Chao-Ran [1 ,2 ]
机构
[1] School of Electronic Information, Hangzhou Dianzi University, Zhejiang, Hangzhou,310018, China
[2] Smart Microsensor and Microsystem Engineering Research Center, Ministry of Education, Zhejiang, Hangzhou,310018, China
来源
关键词
Blood pressure;
D O I
10.12263/DZXB.20230191
中图分类号
学科分类号
摘要
The flexible sensor based on photo plethysmo graphy (PPG) can detect heart rate (HR) and blood pressure (BP), but the calibration of their detection results is rarely reported. Therefore, this paper proposes a reflective PPG heart rate detection and blood pressure calibration system based on simulated blood circulation. The peristaltic pump is used to generate pulsating flow,and the frequency and pressure of simulated blood delivery are controlled by adjusting its rotational speed,thus causing the change of the volume of simulated blood in the elastic latex tube and changing the signal period and intensity of reflected light, which is closer to match the actual scenario of human pulse measurement process. The mean value of heart rate detection error of the system is 0.277 78, and the 95% consistency limit is (-2.595 62, 3.151 17). The goodness of fit of measured systolic blood pressure (SBP) and diastolic blood pressure (DBP) are 0.971 85 and 0.981 11, respectively. The mean value of mean deviation (MD) ± standard deviation (SD) of SBP and DBP detected by the calibrated flexible PPG sensor on four volunteers is (1.21±2.16) mmHg and (0.76±2.02) mmHg, respectively, which are in line with and far less than the standard index of 5±8 mmHg for measuring the accuracy of blood pressure monitors set by the association for the advancement of medical instrumentation (AAMI). The results show that this system can calibrate the flexible PPG sensor accurately and efficiently, which provides the calibration basis for the accurate blood pressure detection of por- table wearable devices. © 2024 Chinese Institute of Electronics. All rights reserved.
引用
收藏
页码:2648 / 2658
相关论文
共 50 条
  • [1] Research on the sensor calibration of pressure transmitter based on the least square method
    Wang Zhiping
    Xu Aidong
    Wang Kai
    Song Yan
    Yan Bingjun
    2014 12TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP), 2014, : 389 - 392
  • [2] An Unobtrusive and Calibration-free Blood Pressure Estimation Method using Photoplethysmography and Biometrics
    Xing, Xiaoman
    Ma, Zhimin
    Zhang, Mingyou
    Zhou, Ying
    Dong, Wenfei
    Song, Mingxuan
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] An Unobtrusive and Calibration-free Blood Pressure Estimation Method using Photoplethysmography and Biometrics
    Xiaoman Xing
    Zhimin Ma
    Mingyou Zhang
    Ying Zhou
    Wenfei Dong
    Mingxuan Song
    Scientific Reports, 9
  • [4] Research on Sitting Posture Detection Method Based on Flexible Film Pressure Sensor
    Liu, Caiwei
    Wu, Jun
    Yi, Mingdong
    Li, Yunxia
    Cen, Fengjie
    Wei, Wei
    INTERNATIONAL CONFERENCE ON SENSORS AND INSTRUMENTS (ICSI 2021), 2021, 11887
  • [5] Improved Blood Pressure Estimation using Photoplethysmography based on Ensemble Method
    Pan, Junjun
    Zhang, Yue
    2017 14TH INTERNATIONAL SYMPOSIUM ON PERVASIVE SYSTEMS, ALGORITHMS AND NETWORKS & 2017 11TH INTERNATIONAL CONFERENCE ON FRONTIER OF COMPUTER SCIENCE AND TECHNOLOGY & 2017 THIRD INTERNATIONAL SYMPOSIUM OF CREATIVE COMPUTING (ISPAN-FCST-ISCC), 2017, : 105 - 111
  • [6] Development of an auto calibration method for the mplantable blood pressure sensor in the UPVAD
    Saito, I.
    Shi, W.
    Chinzei, T.
    Isoyama, T.
    Miura, H.
    Kouno, A.
    Ono, T.
    Nakagawa, H.
    Yamaguchi, S.
    Mitsumune, N.
    Inoue, Y.
    Kishi, A.
    Abe, Y.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (08): : 691 - 691
  • [7] Continuous blood pressure measurement based on photoplethysmography
    Chen Yi
    Cheng Jian
    Ji Wenqiang
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 1656 - 1663
  • [8] A Blood Pressure Prediction Method Based on Imaging Photoplethysmography in combination with Machine Learning
    Rong, Meng
    Li, Kaiyang
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 64
  • [9] Research on static calibration method of flexible three-dimensional tactile sensor
    Huang, Bin
    Yu, Xiaofen
    Huang, Ying
    Huang, Haiyang
    Wang, Biao
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (09): : 2003 - 2009
  • [10] Flexible sensor for blood pressure measurement
    Sepulveda, A. T.
    Pontes, A. J.
    Viana, J. C.
    de Villoria, R. Guzman
    Fachin, F.
    Wardle, B. L.
    Rocha, L. A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 512 - 515