Numerical calculation of the temperature field of membrane waterwall in burner zone of 600MW supercritical boiler

被引:0
|
作者
Li, Chun-Yan
Yan, Wei-Ping
Liang, Xiu-Jun
Huang, Jing-Li
机构
[1] Department of Mechanical Engineering, North China University of Electric Power, Baoding 071003, China
[2] MOE's Key Lab of Power Equipment's State Monitoring and Control, College of Energy and Power Engineering, North China University of Electric Power, Baoding 071003, China
[3] Shanxi Electric Power Research Institute, Taiyuan 030001, China
来源
Dongli Gongcheng/Power Engineering | 2008年 / 28卷 / 05期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The temperature fields of the membrane waterwall in burner zone of a 600MW boiler under different supercritical conditions are analyzed and calculated based on finite-element method. Bilinear quadrilateral is used in meshing the temperature field of the waterwall. Heat-flux density of the fire-facing side is sectionalized and calculated. The temperature of the working medium and the heat transfer coefficient in the tube are determined based on the actual temperature and pressure of the inlet medium and outlet medium of the waterwall. The temperature distributions of the waterwall under different supercritical working conditions are calculated. The cause of waterwall overheat is analyzed. The calculated results are compared with the measured values, and the error is small.
引用
收藏
页码:677 / 681
相关论文
共 38 条
  • [31] Effect of burner location on flow-field deflection and asymmetric combustion in a 600 MWe supercritical down-fired boiler
    Kuang, Min
    Yang, Guohua
    Zhu, Qunyi
    Ti, Shuguang
    Wang, Zhenfeng
    APPLIED ENERGY, 2017, 206 : 1393 - 1405
  • [33] Numerical Investigation on Co-firing Characteristics of Semi-Coke and Lean Coal in a 600 MW Supercritical Wall-Fired Boiler
    Wang, Chang'an
    Feng, Qinqin
    Lv, Qiang
    Zhao, Lin
    Du, Yongbo
    Wang, Pengqian
    Zhang, Jingwen
    Che, Defu
    APPLIED SCIENCES-BASEL, 2019, 9 (05):
  • [34] Numerical analysis and modified thermodynamic calculation methods for the furnace in the 1000 MW supercritical CO2 coal-fired boiler
    Zhou, Jing
    Zhu, Meng
    Su, Sheng
    Chen, Lei
    Xu, Jun
    Hu, Song
    Wang, Yi
    Jiang, Long
    Zhong, Wenqi
    Xiang, Jun
    ENERGY, 2020, 212 (212)
  • [35] Trends of the Flow-Field Deflection and Asymmetric Combustion in a 600 MWe Supercritical Down-Fired Boiler with Respect to the Furnace Arch's Burner Span
    Kuang, Min
    Yang, Guohua
    Zhu, Qunyi
    Ti, Shuguang
    ENERGY & FUELS, 2017, 31 (11) : 12770 - 12779
  • [36] Effect of burner location on flow-field deflection and asymmetric combustion in a 600 MWe supercritical down-fired boiler (vol 206, pg 1393, 2017)
    Kuang, Min
    Yang, Guohua
    Zhu, Qunyi
    Ti, Shuguang
    Wang, Zhenfeng
    APPLIED ENERGY, 2018, 229 : 1287 - 1288
  • [37] Analysisze of non-uniform distribution of gas-solid flow in the 600MW (e) CFB boiler based on the non-uniform distribution of returning ash temperature
    Mo X.
    Cai R.
    Lü J.
    Yang H.
    Lei X.
    Ling W.
    Su H.
    Zhou Q.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2016, 36 (08): : 2175 - 2180
  • [38] Evaluation on cold modeling flow field for a down-fired 600 MWe supercritical boiler with multi-injection and multi-staging: A burner location experimental optimization and its validation by real-furnace measurements
    Kuang, Min
    Li, Zhengqi
    Zhu, Qunyi
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 45 : 213 - 220