Determination of a small elliptical anomaly in electrical impedance tomography using minimal measurements

被引:0
|
作者
Chen, Gaoming [1 ]
Santosa, Fadil [2 ]
Titi, Aseel [2 ]
机构
[1] Renming Univ, Sch Math, Beijing, Peoples R China
[2] Johns Hopkins Univ, Dept Appl Math & Stat, Baltimore, MD 21218 USA
关键词
electrical impedance tomography; small conductivity anomaly; minimal measurements; optimal experiment design; INVERSE CONDUCTIVITY PROBLEM; CRACKS; UNIQUENESS; ALGORITHM;
D O I
10.1088/1361-6420/ad7d2e
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
We consider the problem of determining a small elliptical conductivity anomaly in a unit disc from boundary measurements. The conductivity of the anomaly is assumed to be a small perturbation from the constant background. A measurement of voltage across two point-electrodes on the boundary through which a constant current is passed. We further assume the limiting case when the distance between two electrodes go to zero, creating a dipole field. We show that three such measurements suffice to locate the anomaly size and location inside the disc. Two further measurements are needed to obtain the aspect ratio and the orientation of the ellipse. The investigation includes the studies of the stability of the inverse problem and optimal experiment design.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Determination of absolute lung resistivity as a function of air volume using electrical impedance tomography
    Zhang, J
    Patterson, RP
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3083 - 3086
  • [32] Symmetry difference electrical impedance tomography-a novel modality for anomaly detection
    McDermott, Barry
    Porter, Emily
    Jones, Marggie
    McGinley, Brian
    O'Halloran, Martin
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (04)
  • [33] DETERMINATION OF UPPER ARM MUSCLE AND FAT AREAS USING ELECTRICAL-IMPEDANCE MEASUREMENTS
    BROWN, BH
    KARATZAS, T
    NAKIELNY, R
    CLARKE, RG
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (01): : 47 - 55
  • [34] Study on human brain impedance imaging using electrical impedance tomography
    Xu, GZ
    Dong, GY
    Yan, WL
    Yang, QX
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS, 2000, : 378 - 380
  • [35] Using electrical impedance tomography for rapid determination of starch and soluble sugar contents in Rosa hybrida
    Ji Qian
    Juan Zhou
    Bao Di
    Yang Liu
    Gang Zhang
    Xin Yang
    Scientific Reports, 11
  • [36] Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography
    Zhang, Jie
    Patterson, Robert
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S45 - S56
  • [37] Using electrical impedance tomography for rapid determination of starch and soluble sugar contents in Rosa hybrida
    Qian, Ji
    Zhou, Juan
    Di, Bao
    Liu, Yang
    Zhang, Gang
    Yang, Xin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [38] Pyramidal resistor networks for electrical impedance tomography with partial boundary measurements
    Borcea, L.
    Druskin, V.
    Mamonov, A. V.
    Vasquez, F. Guevara
    INVERSE PROBLEMS, 2010, 26 (10)
  • [39] Circular resistor networks for electrical impedance tomography with partial boundary measurements
    Borcea, L.
    Druskin, V.
    Mamonov, A. V.
    INVERSE PROBLEMS, 2010, 26 (04)
  • [40] Ultrasound Modulated Electrical Impedance Tomography by Contrast Libraries of Measurements Variation
    Zhang, Shengnan
    Xu, Yanbin
    Dong, Feng
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 1027 - 1032