Using continuous PM2.5 monitoring data to report an air quality index

被引:0
|
作者
Bortnick, Steven M. [1 ]
Coutant, Basil W. [1 ]
Eberly, Shelly I. [1 ]
机构
[1] Battelle Memorial Institute, 505 King Avenue, Columbus, OH 43201-2693, United States
来源
| 2002年 / Taylor and Francis Inc.卷 / 52期
关键词
Environmental protection - Regression analysis - Synthesis (chemical) - Thermal effects;
D O I
暂无
中图分类号
学科分类号
摘要
As stated in 40 CFR 58, Appendix G (2000), statistical linear regression models can be applied to relate PM2.5 continuous monitoring (CM) measurements with federal reference method (FRM) measurements, collocated or otherwise, for the purpose of reporting the air quality index (AQI). The CM measurements can then be transformed via the model to remove any bias relative to FRM measurements. The resulting FRM-like modeled measurements may be used to provide more timely reporting of a metropolitan statistical area's (MSA's) AQI.1 Of considerable importance is the quality of the model used to relate the CM and FRM measurements. The use of a poor model could result in misleading AQI reporting in the form of incorrectly claiming either good or bad air quality. This paper describes a measure of adequacy for deciding whether a statistical linear regression model that relates FRM and continuous PM2.5 measurements is sufficient for use in AQI reporting. The approach is the U.S. Environmental Protection Agency's (EPA's) data quality objectives (DQO) process, a seven-step strategic planning approach to determine the most appropriate data type, quality, quantity, and synthesis for a given activity.2 The chosen measure of model adequacy is r2, the square of the correlation coefficient between FRM measurements and their modeled counterparts. The paper concludes by developing regression models that meet this desired level of adequacy for the MSAs of Greensboro/Winston-Salem/High Point, NC; and Davenport/Moline/Rock Island, IA/IL. In both cases, a log transformation of the data appeared most appropriate. For the data from the Greensboro/Winston-Salem/High Point MSA, a simple linear regression model of the FRM and CM measurements had an r2 of 0.96, based on 227 paired observations. For the data from the Davenport/Moline/Rock Island MSA, due to seasonal differences between CM and FRM measurements, the simple linear regression model had to be expanded to include a temperature dependency, resulting in an r2 of 0.86, based on 214 paired observations.
引用
收藏
相关论文
共 50 条
  • [31] Monitoring and source apportionment of trace elements in PM2.5: Implications for local air quality management
    Li, Yueyan
    Chang, Miao
    Ding, Shanshan
    Wang, Shiwen
    Ni, Dun
    Hu, Hongtao
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2017, 196 : 16 - 25
  • [32] Air quality management in Chile: Effectiveness of PM2.5 regulations
    Jorquera, Hector
    URBAN CLIMATE, 2021, 35
  • [33] Estimating ground-level PM2.5 levels in Taiwan using data from air quality monitoring stations and high coverage of microsensors
    Ho, Chi-Chang
    Chen, Ling-Jyh
    Hwang, Jing-Shiang
    ENVIRONMENTAL POLLUTION, 2020, 264 (264)
  • [34] Traffic impacts on PM2.5 air quality in Nairobi, Kenya
    Kinney, Patrick L.
    Gichuru, Michael Gatari
    Volavka-Close, Nicole
    Ngo, Nicole
    Ndiba, Peter K.
    Law, Anna
    Gachanja, Anthony
    Gaita, Samuel Mwaniki
    Chillrud, Steven N.
    Sclar, Elliott
    ENVIRONMENTAL SCIENCE & POLICY, 2011, 14 (04) : 369 - 378
  • [35] Modeling approach for emissions reduction of primary PM2.5 and secondary PM2.5 precursors to achieve the air quality target
    Chen, Tu-Fu
    Chang, Ken-Hui
    Tsai, Chang-You
    ATMOSPHERIC RESEARCH, 2017, 192 : 11 - 18
  • [36] Zoning of air quality index (PM10 and PM2.5) by Arc-GIS for Khorramabad city, Iran
    Kianisadr, Maryam
    Ghaderpoori, Mansour
    Jafari, Ali
    Kamarehie, Bahram
    Karami, Mohammadamin
    DATA IN BRIEF, 2018, 19 : 1131 - 1141
  • [37] A CMOS Particulate Matter 2.5 (PM2.5) Concentration to Frequency Converter with Calibration Circuits for Air Quality Monitoring Applications
    Chiang, Cheng-Ta
    Huang, Ssu-Wei
    Liu, Guan-Xian
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 966 - 970
  • [38] Outdoor PM2.5 air filtration: optimising indoor air quality and energy
    Belias, Evangelos
    Licina, Dusan
    BUILDINGS & CITIES, 2022, 3 (01): : 186 - 203
  • [40] Estimating background concentrations of PM2.5 for urban air quality modelling in a data poor environment
    Draper, Eve L.
    Whyatt, J. Duncan
    Taylor, Richard S.
    Metcalfe, Sarah E.
    ATMOSPHERIC ENVIRONMENT, 2023, 314