Using continuous PM2.5 monitoring data to report an air quality index

被引:0
|
作者
Bortnick, Steven M. [1 ]
Coutant, Basil W. [1 ]
Eberly, Shelly I. [1 ]
机构
[1] Battelle Memorial Institute, 505 King Avenue, Columbus, OH 43201-2693, United States
来源
| 2002年 / Taylor and Francis Inc.卷 / 52期
关键词
Environmental protection - Regression analysis - Synthesis (chemical) - Thermal effects;
D O I
暂无
中图分类号
学科分类号
摘要
As stated in 40 CFR 58, Appendix G (2000), statistical linear regression models can be applied to relate PM2.5 continuous monitoring (CM) measurements with federal reference method (FRM) measurements, collocated or otherwise, for the purpose of reporting the air quality index (AQI). The CM measurements can then be transformed via the model to remove any bias relative to FRM measurements. The resulting FRM-like modeled measurements may be used to provide more timely reporting of a metropolitan statistical area's (MSA's) AQI.1 Of considerable importance is the quality of the model used to relate the CM and FRM measurements. The use of a poor model could result in misleading AQI reporting in the form of incorrectly claiming either good or bad air quality. This paper describes a measure of adequacy for deciding whether a statistical linear regression model that relates FRM and continuous PM2.5 measurements is sufficient for use in AQI reporting. The approach is the U.S. Environmental Protection Agency's (EPA's) data quality objectives (DQO) process, a seven-step strategic planning approach to determine the most appropriate data type, quality, quantity, and synthesis for a given activity.2 The chosen measure of model adequacy is r2, the square of the correlation coefficient between FRM measurements and their modeled counterparts. The paper concludes by developing regression models that meet this desired level of adequacy for the MSAs of Greensboro/Winston-Salem/High Point, NC; and Davenport/Moline/Rock Island, IA/IL. In both cases, a log transformation of the data appeared most appropriate. For the data from the Greensboro/Winston-Salem/High Point MSA, a simple linear regression model of the FRM and CM measurements had an r2 of 0.96, based on 227 paired observations. For the data from the Davenport/Moline/Rock Island MSA, due to seasonal differences between CM and FRM measurements, the simple linear regression model had to be expanded to include a temperature dependency, resulting in an r2 of 0.86, based on 214 paired observations.
引用
收藏
相关论文
共 50 条
  • [21] Semi-volatile species in PM2.5: Comparison of integrated and continuous samplers for PM2.5 research or monitoring
    Pang, Y.
    Ren, Y.
    Obeidi, F.
    Hastings, R.
    Eatough, D.J.
    Wilson, W.E.
    Journal of the Air and Waste Management Association, 2001, 51 (01): : 25 - 36
  • [22] Semi-volatile species in PM2.5:: Comparison of integrated and continuous samplers for PM2.5 research or monitoring
    Pang, YB
    Ren, Y
    Obeidi, F
    Hastings, R
    Eatough, DJ
    Wilson, WE
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (01): : 25 - 36
  • [23] Does national air quality monitoring reduce local air pollution? The case of PM2.5 for China
    Liu, Guixian
    Dong, Xiucheng
    Kong, Zhaoyang
    Dong, Kangyin
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2021, 296
  • [24] PM2.5: Air Monitoring Methods, Measurement, and Global Impact
    Joshi, Vivek
    LC GC NORTH AMERICA, 2018, 36 (12) : 868 - 869
  • [25] A simple method for the detection of PM2.5 air pollutions using MODIS data
    Kato, Yoshinobu
    REMOTE SENSING OF THE ATMOSPHERE, CLOUDS, AND PRECIPITATION VI, 2016, 9876
  • [26] PM2.5 data reliability, consistency, and air quality assessment in five Chinese cities
    Liang, Xuan
    Li, Shuo
    Zhang, Shuyi
    Huang, Hui
    Chen, Song Xi
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2016, 121 (17) : 10220 - 10236
  • [27] PM2.5 emissions, concentrations and air quality index during the COVID-19 lockdown
    Rojas, Nestor Y.
    Ramirez, Omar
    Carlos Belalcazar, Luis
    Felipe Mendez-Espinosa, Juan
    Mario Vargas, Jorge
    Eduardo Pachon, Jorge
    ENVIRONMENTAL POLLUTION, 2021, 272
  • [28] Assessment of PM2.5 monitoring using MicroPEM: A validation study in a city with elevated PM2.5 levels
    Du, Yanjun
    Wang, Qin
    Sun, Qinghua
    Zhang, Ting
    Li, Tiantian
    Yan, Beizhan
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2019, 171 : 518 - 522
  • [29] Effects of Precipitation on the Air Quality Index, PM2.5 Levels and on the Dry Deposition of PCDD/Fs in the Ambient Air
    Wang, Ruoxin
    Cui, Kangping
    Sheu, Hwey-Lin
    Wang, Lin-Chi
    Liu, Xueyan
    AEROSOL AND AIR QUALITY RESEARCH, 2023, 23 (04)
  • [30] PM2.5 Concentration Prediction Using GRA-GRU Network in Air Monitoring
    Qing, Ling
    SUSTAINABILITY, 2023, 15 (03)