Using continuous PM2.5 monitoring data to report an air quality index

被引:0
|
作者
Bortnick, Steven M. [1 ]
Coutant, Basil W. [1 ]
Eberly, Shelly I. [1 ]
机构
[1] Battelle Memorial Institute, 505 King Avenue, Columbus, OH 43201-2693, United States
来源
| 2002年 / Taylor and Francis Inc.卷 / 52期
关键词
Environmental protection - Regression analysis - Synthesis (chemical) - Thermal effects;
D O I
暂无
中图分类号
学科分类号
摘要
As stated in 40 CFR 58, Appendix G (2000), statistical linear regression models can be applied to relate PM2.5 continuous monitoring (CM) measurements with federal reference method (FRM) measurements, collocated or otherwise, for the purpose of reporting the air quality index (AQI). The CM measurements can then be transformed via the model to remove any bias relative to FRM measurements. The resulting FRM-like modeled measurements may be used to provide more timely reporting of a metropolitan statistical area's (MSA's) AQI.1 Of considerable importance is the quality of the model used to relate the CM and FRM measurements. The use of a poor model could result in misleading AQI reporting in the form of incorrectly claiming either good or bad air quality. This paper describes a measure of adequacy for deciding whether a statistical linear regression model that relates FRM and continuous PM2.5 measurements is sufficient for use in AQI reporting. The approach is the U.S. Environmental Protection Agency's (EPA's) data quality objectives (DQO) process, a seven-step strategic planning approach to determine the most appropriate data type, quality, quantity, and synthesis for a given activity.2 The chosen measure of model adequacy is r2, the square of the correlation coefficient between FRM measurements and their modeled counterparts. The paper concludes by developing regression models that meet this desired level of adequacy for the MSAs of Greensboro/Winston-Salem/High Point, NC; and Davenport/Moline/Rock Island, IA/IL. In both cases, a log transformation of the data appeared most appropriate. For the data from the Greensboro/Winston-Salem/High Point MSA, a simple linear regression model of the FRM and CM measurements had an r2 of 0.96, based on 227 paired observations. For the data from the Davenport/Moline/Rock Island MSA, due to seasonal differences between CM and FRM measurements, the simple linear regression model had to be expanded to include a temperature dependency, resulting in an r2 of 0.86, based on 214 paired observations.
引用
收藏
相关论文
共 50 条
  • [1] Using continuous PM2.5 monitoring data to report an air quality index
    Bortnick, SM
    Coutant, BW
    Eberly, SI
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2002, 52 (01): : 104 - 112
  • [2] PM2.5 Air Quality Index Prediction Using an Ensemble Learning Model
    Xu, Wei
    Cheng, Cheng
    Guo, Danhuai
    Chen, Xin
    Yuan, Hui
    Yang, Rui
    Liu, Yi
    WEB-AGE INFORMATION MANAGEMENT: WAIM 2014 INTERNATIONAL WORKSHOPS, 2014, 8597 : 119 - 129
  • [3] The Microbial Activity in PM2.5 in Indoor Air: As an Index of Air Quality Level
    Chen, Hanlin
    Du, Rui
    Ren, Weishan
    Zhang, Sujian
    Du, Pengrui
    Zhang, Yongtao
    AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (02) : 1 - 13
  • [4] Air quality monitoring design:: Optimization of PM2.5 networks using satellite observations
    Saisana, M
    Sarigiannis, D
    Chaloulakou, A
    Spyrellis, N
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOLS A AND B, 2001, : 747 - 754
  • [5] Air quality, PM2.5, and related concerns
    Mitloehner, F. M.
    JOURNAL OF ANIMAL SCIENCE, 2004, 82 : 80 - 80
  • [6] IMPACT OF AIR QUALITY INDEX (AQI) AND PARTICULATE MATTER 2.5 (PM2.5) ON THE INCIDENCE OF STROKE
    Ali, M.
    Zaidi, S.
    Kazi, H.
    Shahab, F.
    INTERNATIONAL JOURNAL OF STROKE, 2024, 19 (02) : 202 - 202
  • [7] CAQI Common Air Quality Index - Update with PM2.5 and sensitivity analysis
    van den Elshout, Sef
    Leger, Karine
    Heich, Hermann
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 488 : 463 - 470
  • [8] Air quality, PM2.5, and related concerns
    Mitloehner, F. M.
    JOURNAL OF DAIRY SCIENCE, 2004, 87 : 80 - 80
  • [9] Air quality, PM2.5, and related concerns
    Mitloehner, F. M.
    POULTRY SCIENCE, 2004, 83 : 80 - 80
  • [10] PM2.5 CONCENTRATION PREDICTION USING DEEP LEARNING IN AIR MONITORING
    Huang, Yi
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (12): : 13200 - 13211