Attenuation correction using SPECT emission data only

被引:29
|
作者
Gourion, Daniel [1 ]
Noll, Dominikus [2 ]
Gantet, Pierre [1 ]
Celler, Anna [3 ]
Esquerré, Jean-Paul [4 ]
机构
[1] Laboratoire de Biophysique Purpan, 31077 Toulouse, France
[2] Lab. Math. pour l'Industrie Physique, Universite Paul Sabatier, 31062 Toulouse, France
[3] Vancouver Hosp. and Health Sci. Ctr., Vancouver, BC V5Z 1M9, Canada
[4] Hopital Toulouse Purpan, Service de Medecine Nucleaire, 31059 Toulouse, France
关键词
Crosstalk - Image enhancement - Image reconstruction - Inverse problems - Mathematical transformations - Optimization - Poisson distribution;
D O I
10.1109/TNS.2002.803862
中图分类号
学科分类号
摘要
A major step toward quantitative single photon emission computerized tomography (SPECT) imaging may be achieved if attenuation, scatter, and blurring effects are accounted for in the reconstruction process. Here we consider an approach which simultaneously estimates the unknown attenuation coefficient and the emission source using the emission data only. This leads to an inverse mathematical problem which may no longer be solved via iterative procedures like the well-known EM-algorithm. Instead, a regularization approach based on nonlinear optimization techniques is used. We present a successful strategy and test it in a simulated case study and a physical phantom experiment.
引用
收藏
页码:2172 / 2179
相关论文
共 50 条
  • [31] Attenuation correction in cardiac spect using consistency conditions
    da Silva, Ana Maria Marques
    Robilotta, Cecil Chow
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 271 - +
  • [32] Validation of attenuation correction using SPECT/CT in MPI
    Ali, L.
    Panchadar, S.
    Al-Sayed, Y.
    Biswas, G.
    Al-Garashi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S493 - S493
  • [33] Attenuation map reconstruction from emission and transmission SPECT data
    Erlandsson, K
    Waddington, WA
    Cullum, ID
    Davies, G
    Pilowsky, LS
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1251 - 1254
  • [34] Attenuation correction in SPECT without attenuation map
    Kacperski, Krzysztof
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3820 - 3822
  • [35] Attenuation correction in SPECT CT
    Reimann, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S287 - S287
  • [36] Is it time for SPECT attenuation correction?
    Denny D. Watson
    Journal of Nuclear Cardiology, 2004, 11 : 239 - 241
  • [37] Attenuation correction algorithms in SPECT
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2000, 40 (01): : 52 - 56
  • [38] Is it time for SPECT attenuation correction?
    Watson, DD
    JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) : 239 - 241
  • [39] Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc
    Bakhshandeh, Mohsen
    Rajabi, Hossein
    Vafamanesh, Masoud
    Sharafi, Ali Akbar
    Seifollahi, Shahram
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2006, 14 (02):
  • [40] Registration problem in attenuation map estimation using only emission data with data consistency conditions.
    Panin, VY
    Zeng, GL
    Gullberg, GT
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 294P - 294P