Attenuation correction using SPECT emission data only

被引:29
|
作者
Gourion, Daniel [1 ]
Noll, Dominikus [2 ]
Gantet, Pierre [1 ]
Celler, Anna [3 ]
Esquerré, Jean-Paul [4 ]
机构
[1] Laboratoire de Biophysique Purpan, 31077 Toulouse, France
[2] Lab. Math. pour l'Industrie Physique, Universite Paul Sabatier, 31062 Toulouse, France
[3] Vancouver Hosp. and Health Sci. Ctr., Vancouver, BC V5Z 1M9, Canada
[4] Hopital Toulouse Purpan, Service de Medecine Nucleaire, 31059 Toulouse, France
关键词
Crosstalk - Image enhancement - Image reconstruction - Inverse problems - Mathematical transformations - Optimization - Poisson distribution;
D O I
10.1109/TNS.2002.803862
中图分类号
学科分类号
摘要
A major step toward quantitative single photon emission computerized tomography (SPECT) imaging may be achieved if attenuation, scatter, and blurring effects are accounted for in the reconstruction process. Here we consider an approach which simultaneously estimates the unknown attenuation coefficient and the emission source using the emission data only. This leads to an inverse mathematical problem which may no longer be solved via iterative procedures like the well-known EM-algorithm. Instead, a regularization approach based on nonlinear optimization techniques is used. We present a successful strategy and test it in a simulated case study and a physical phantom experiment.
引用
收藏
页码:2172 / 2179
相关论文
共 50 条
  • [21] Joint reconstruction of activity and attenuation map using LM SPECT emission data
    Jha, Abhinav K.
    Clarkson, Eric
    Kupinski, Matthew A.
    Barrett, Harrison H.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [22] PROBLEMS RELATED USING TRANSMISSION AND CT DATA FOR NONUNIFORM ATTENUATION CORRECTION IN SPECT
    KNESAUREK, K
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (09) : 1839 - 1839
  • [23] SPECT attenuation correction based on combined transmission-emission reconstruction of the attenuation map
    Bronnikov, AV
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3484 - 3486
  • [24] Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT
    van Dijk, J. D.
    Mouden, M.
    Ottervanger, J.
    van Dalen, J. A.
    Knollema, S.
    Slump, C. H.
    Jager, P. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S228 - S228
  • [25] Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT
    J. D. van Dijk
    M. Mouden
    J. P. Ottervanger
    J. A. van Dalen
    S. Knollema
    C. H. Slump
    P. L. Jager
    Journal of Nuclear Cardiology, 2017, 24 : 395 - 401
  • [26] Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT
    van Dijk, J. D.
    Mouden, M.
    Ottervanger, J. P.
    van Dalen, J. A.
    Knollema, S.
    Slump, C. H.
    Jager, P. L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (02) : 395 - 401
  • [27] ATTENUATION CORRECTION OF THALLIUM SPECT USING DIFFERENTIAL ATTENUATION OF THALLIUM PHOTONS
    HANSEN, CL
    SIEGEL, JA
    VANDECKER, WA
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (10) : 1746 - 1746
  • [28] ATTENUATION CORRECTION OF THALLIUM SPECT USING DIFFERENTIAL ATTENUATION OF THALLIUM PHOTONS
    HANSEN, CL
    SIEGEL, JA
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (08) : 1574 - 1577
  • [29] A NONUNIFORM ATTENUATION CORRECTION FOR QUANTITATIVE THORAX SPECT BASED ON LUNG EMISSION
    TURKINGTON, TG
    JASZCZAK, RJ
    GILLAND, DR
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P190 - P190
  • [30] QUANTITATIVE SPECT BY ATTENUATION CORRECTION OF THE PROJECTION SET USING TRANSMISSION DATA - EVALUATION OF A METHOD
    ALMQUIST, H
    PALMER, J
    LJUNGBERG, M
    WOLLMER, P
    STRAND, SE
    JONSON, B
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (8-10): : 587 - 594