Design and construction of the cylindrical drift chamber for the COMET Phase-I experiment

被引:0
|
作者
Satoa, A. [1 ]
Yoshida, H. [1 ,2 ]
Moritsu, M. [3 ]
Jiang, X. [4 ,5 ]
Kuno, Y. [1 ,2 ]
Li, H. -B. [4 ,5 ]
Li, W. -G. [4 ,5 ,9 ]
Matsuda, Y. [1 ]
Miao, H. [4 ,5 ]
Nakamura, Y. [1 ]
Nakatsugawa, Y. [7 ]
Nakazawa, Y. [8 ]
Ohta, S. [1 ]
Okinaka, K. [1 ]
Sakamoto, H. [1 ]
Wong, M. L. [1 ]
Wong, T. S. [1 ]
Wu, C. [4 ,6 ]
Xing, T. -Y. [4 ,5 ]
Yamane, T. [1 ]
Yuan, Y. [5 ]
Zhang, J. [4 ,5 ]
Zhang, Y. [4 ]
Zhang, Z. -K. [4 ,5 ]
机构
[1] Osaka Univ, Dept Phys, 1-1 Machikaneyama, Toyonaka, Osaka 5600043, Japan
[2] Osaka Univ, Res Ctr Nucl Phys, 10-1 Mihogaoka, Suita, Osaka 5670047, Japan
[3] Kyushu Univ, Dept Phys, 744 Motooka,Nishi ku, Fukuoka 8190395, Japan
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[5] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[6] Spallat Neutron Source Sci Ctr, Dongguan 523808, Peoples R China
[7] Wakayama Med Univ, 811-1 Kimiidera, Wakayama, Wakayama 6418509, Japan
[8] KEK, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
[9] Univ Liverpool, Dept Phys, Liverpool L69 3BX, Merseyside, England
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2024年 / 1069卷
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Gas detector; Drift chamber; Cylindrical detector; Muon; Particle physics; Lepton-flavor violation; READOUT ELECTRONICS; DETECTOR;
D O I
10.1016/j.nima.2024.169926
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
COMET is an experiment at J-PARC that searches for the charged lepton flavor violating process of neutrinoless muon-to-electron conversion (mu -> e conversion) in a muonic atom. The COMET Phase-I experiment, which represents the first stage of its staged approach, utilizes the cylindrical drift chamber (CDC) as the main detector to measure the momentum of electrons emitted from mu -> e conversion in a 1 T magnetic field. The CDC is designed for optimal performance to achieve the best momentum resolution and effectively separate the mu -> e conversion electron signal from background signals. This design entails adapting He:i-C4H10 (90:10) as its chamber gas and employing an all-stereo wire configuration. This document provides a comprehensive overview of the CDC detector, encompassing design considerations, mechanical structure, construction methodologies, and results of performance evaluations conducted using cosmic-rays.
引用
收藏
页数:15
相关论文
共 50 条
  • [42] Design and Evaluation of the LAr Trigger Digitizer Board in the ATLAS Phase-I Upgrade
    Besin, Dominique
    Chen, Hucheng
    Chen, Kai
    Citterio, Mauro
    Deschamps, Herve
    Grabas, Aude
    Lanni, Francesco
    Latorre, Stefano
    Lazzaroni, Massimo
    Liu, Hongbin
    Pleier, Marc-Andre
    Schwemling, Phillippe
    Simion, Stefan
    Tang, Shaochun
    Xu, Hao
    Zhu, Heling
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (08) : 2011 - 2016
  • [43] ANALYSIS OF PHASE-I OF THE ORNL HTGR BOTTOM REFLECTOR AND SUPPORT BLOCK NEUTRON STREAMING EXPERIMENT
    SLATER, CO
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 637 - 638
  • [44] DESIGN AND GENERAL FINDINGS OF PHASE-I OF THE CROSS-LANGUAGE APHASIA STUDY
    MENN, L
    OBLER, LK
    JOURNAL OF CLINICAL AND EXPERIMENTAL NEUROPSYCHOLOGY, 1988, 10 (03) : 333 - 333
  • [45] OCCUPATIONAL-HEALTH EXPERIENCE IN THE CONSTRUCTION OF PHASE-I OF THE MASS RAPID TRANSIT SYSTEM IN SINGAPORE
    LEE, HS
    CHAN, OY
    PHOON, WH
    JOURNAL OF THE SOCIETY OF OCCUPATIONAL MEDICINE, 1988, 38 (1-2): : 3 - 8
  • [46] The GERDA experiment and first results from phase-I detector operation in LAr/LN2
    di Vacri, A.
    MEASUREMENTS OF NEUTRINO MASS, 2009, 170 : 419 - 422
  • [47] Design and Construction of a cylindrical GEM detector as the Inner Tracker device of the KLOE-2 experiment
    Balla, A.
    Bencivenni, G.
    Cerioni, S.
    Ciambrone, P.
    De Lucia, E.
    Domenici, D.
    Dong, J.
    Felici, G.
    Gatta, M.
    Jacewicz, M.
    Lauciani, S.
    Morello, G.
    Patera, V.
    Pistilli, M.
    Quintieri, L.
    Tshadadze, E.
    De Robertis, G.
    Fanizzi, G.
    Lacalamita, N.
    Liuzzi, R.
    Loddo, F.
    Mongelli, M.
    Ranieri, A.
    Valentino, V.
    Schioppa, M.
    Di Domenico, A.
    Capodiferro, M.
    Pelosi, A.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 522 - 529
  • [49] USING TOXICITY GRADES IN THE DESIGN AND ANALYSIS OF CANCER PHASE-I CLINICAL-TRIALS
    GORDON, NH
    WILLSON, JKV
    STATISTICS IN MEDICINE, 1992, 11 (16) : 2063 - 2075
  • [50] USING THE TOLERABLE-DOSE DIAGRAM IN THE DESIGN OF PHASE-I COMBINATION CHEMOTHERAPY TRIALS
    KORN, EL
    SIMON, R
    JOURNAL OF CLINICAL ONCOLOGY, 1993, 11 (04) : 794 - 801