Design and construction of the cylindrical drift chamber for the COMET Phase-I experiment

被引:0
|
作者
Satoa, A. [1 ]
Yoshida, H. [1 ,2 ]
Moritsu, M. [3 ]
Jiang, X. [4 ,5 ]
Kuno, Y. [1 ,2 ]
Li, H. -B. [4 ,5 ]
Li, W. -G. [4 ,5 ,9 ]
Matsuda, Y. [1 ]
Miao, H. [4 ,5 ]
Nakamura, Y. [1 ]
Nakatsugawa, Y. [7 ]
Nakazawa, Y. [8 ]
Ohta, S. [1 ]
Okinaka, K. [1 ]
Sakamoto, H. [1 ]
Wong, M. L. [1 ]
Wong, T. S. [1 ]
Wu, C. [4 ,6 ]
Xing, T. -Y. [4 ,5 ]
Yamane, T. [1 ]
Yuan, Y. [5 ]
Zhang, J. [4 ,5 ]
Zhang, Y. [4 ]
Zhang, Z. -K. [4 ,5 ]
机构
[1] Osaka Univ, Dept Phys, 1-1 Machikaneyama, Toyonaka, Osaka 5600043, Japan
[2] Osaka Univ, Res Ctr Nucl Phys, 10-1 Mihogaoka, Suita, Osaka 5670047, Japan
[3] Kyushu Univ, Dept Phys, 744 Motooka,Nishi ku, Fukuoka 8190395, Japan
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[5] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[6] Spallat Neutron Source Sci Ctr, Dongguan 523808, Peoples R China
[7] Wakayama Med Univ, 811-1 Kimiidera, Wakayama, Wakayama 6418509, Japan
[8] KEK, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
[9] Univ Liverpool, Dept Phys, Liverpool L69 3BX, Merseyside, England
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2024年 / 1069卷
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Gas detector; Drift chamber; Cylindrical detector; Muon; Particle physics; Lepton-flavor violation; READOUT ELECTRONICS; DETECTOR;
D O I
10.1016/j.nima.2024.169926
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
COMET is an experiment at J-PARC that searches for the charged lepton flavor violating process of neutrinoless muon-to-electron conversion (mu -> e conversion) in a muonic atom. The COMET Phase-I experiment, which represents the first stage of its staged approach, utilizes the cylindrical drift chamber (CDC) as the main detector to measure the momentum of electrons emitted from mu -> e conversion in a 1 T magnetic field. The CDC is designed for optimal performance to achieve the best momentum resolution and effectively separate the mu -> e conversion electron signal from background signals. This design entails adapting He:i-C4H10 (90:10) as its chamber gas and employing an all-stereo wire configuration. This document provides a comprehensive overview of the CDC detector, encompassing design considerations, mechanical structure, construction methodologies, and results of performance evaluations conducted using cosmic-rays.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] PHASE-I DESIGN IN CLINICO-PHARMACOLOGICAL INVESTIGATION
    DUDECK, J
    HOBEL, W
    VALK, HU
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1973, 23 (11A): : 1625 - 1628
  • [32] Fast Online Trigger using FPGA-based Event Classification for the COMET Phase-I
    Nakazawa, Yu
    Chau, Tai Thanh
    Fujii, Yuki
    Gillies, Ewen
    Ikeno, Masahiro
    Mihara, Satoshi
    Shoji, Masayoshi
    Uchida, Tomohisa
    Ueno, Kazuki
    Lee, MyeongJae
    EUROPEAN PHYSICAL SOCIETY CONFERENCE ON HIGH ENERGY PHYSICS, EPS-HEP2019, 2020,
  • [33] DESIGN AND CONSTRUCTION OF A LARGE CYLINDRICAL TRANSITION RADIATION DETECTOR FOR THE VENUS EXPERIMENT
    SAKUDA, M
    FUKUSHIMA, Y
    HAYASHI, K
    KOHRIKI, T
    NAKAMURA, S
    OGAWA, K
    WATASE, Y
    HABA, J
    KANDA, N
    SUZUKI, A
    SUZUKI, Y
    TSUKAMOTO, A
    YAMAMOTO, H
    CHIBA, Y
    OHSUGI, T
    TAKETANI, A
    TERUNUMA, N
    NAKANO, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (1-2): : 57 - 77
  • [34] The Design of High Speed Trigger Multiplexer Module for the Belle II Cylindrical Drift Chamber Detector
    Wang, C. -H.
    Liu, S. -M.
    Teng, Y. -S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1373 - 1375
  • [35] THE LIBYAN GREAT MAN-MADE RIVER PROJECT PHASE-I .6. STORAGE RESERVOIRS - DESIGN AND CONSTRUCTION
    SAMUEL, HR
    ANDREW, JH
    LEE, CB
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MARITIME AND ENERGY, 1994, 106 (02): : 191 - 202
  • [36] CYLINDRICAL MULTI-LAYER DRIFT CHAMBER FOR A LOW-ENERGY p OVER BAR p EXPERIMENT.
    Kageyama, Tatsuya
    Nakamura, Kenzo
    Sai, Fuminori
    Sakamoto, Shin'ichi
    Sato, Shinji
    Takahashi, Tadayuki
    Tanimori, Tohru
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes, 1985, 24 (11): : 1522 - 1527
  • [37] A DAQ Prototype for the ATLAS small-strip Thin Gap Chamber Phase-I Trigger Upgrade
    Hu, Kun
    Lu, Houbing
    Wang, Xu
    Li, Feng
    Wang, Xinxin
    Geng, Tianru
    Yang, Hang
    Han, Liang
    Jin, Ge
    2016 IEEE-NPSS REAL TIME CONFERENCE (RT), 2016,
  • [38] CONSTRUCTION AND PERFORMANCE OF A THIN CYLINDRICAL MULTIWIRE PROPORTIONAL CHAMBER WITH CATHODE PAD READOUT FOR THE H1-EXPERIMENT
    MULLER, K
    BECK, HP
    BOSIGER, K
    EGLI, S
    EICHENBERGER, S
    MEYER, CA
    ROBMANN, P
    SCHMID, BA
    STRAUMANN, U
    TRUOL, P
    EICHLER, R
    HOLZREUTER, R
    RIEDLBERGER, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (03): : 457 - 466
  • [39] THE DESIGN OF PHASE-I AND PHASE-II CLINICAL-TRIALS IN CANCER - A STATISTICIANS VIEW
    GELLER, NL
    BIOMETRICS, 1984, 40 (04) : 1189 - 1190
  • [40] DESIGN OF PHASE-I AND PHASE-II CLINICAL-TRIALS IN CANCER - A STATISTICIANS VIEW
    DECOSTER, G
    CAVALLI, F
    CANCER INVESTIGATION, 1987, 5 (06) : 649 - 650