Residual current analysis by applying ground fault transfer arc suppression method

被引:2
|
作者
Yu X. [1 ,2 ]
Ouyang J. [1 ,3 ]
Qin L. [1 ,3 ]
机构
[1] Electric Power Research Institute of Guangxi Power Grid, Nanning
[2] Hohai University, Guangxi electric power research institute
[3] Guangxi University, Guangxi electric power research institute
来源
关键词
Arc extinction; Ground fault transfer; Isolated neutral system; Residual current; Single-phase grounding fault;
D O I
10.6329/CIEE.201812_25(6).0001
中图分类号
学科分类号
摘要
When a single-phase grounding fault occurs in isolated neutral systems, ground fault transfer, which makes the fault phase directly ground on the bus, can effectively inhibit the intermittent arc overvoltage. However, the influence of this method on residual current and arc extinction lacks essential investigation and validation. In this paper, distribution characteristics of the capacitive current of each feeder and the load current of fault feeder are analyzed. After ground fault transfer, expressions of the residual current at fault point and the current at bus grounding point are given. Then, the variations of residual current with fault location and transition resistance are analyzed. It can be found that the residual current might be enlarged and even exceed the system capacitive current, because part of the load current of fault feeder passes through the bus grounding point, the earth or the cable sheath and the fault point to the load. It is difficult for arc to extinguish. Therefore, phase-to-phase fault would be caused and personal security even be endangered. Finally, the correctness of theoretic analysis is verified by simulations. © 2018, Chinese Institute of Electrical Engineering. All rights reserved.
引用
收藏
页码:205 / 214
页数:9
相关论文
共 50 条
  • [31] Design of a Controlled Solid State Device for Fault Current Limitation and Arc Flash Suppression
    Alsalemi, S.
    Almadhoun, S.
    Najad, M.
    Massoud, A. M.
    Soliman, R.
    2017 IEEE SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS (ISCAIE), 2017, : 48 - 53
  • [32] Method for Reconstructing Arc Fault Current Signals and an Adaptive Correction Strategy
    Huang, Jinru
    Xu, Zhihong
    Du, Liwei
    CHINESE JOURNAL OF ELECTRICAL ENGINEERING, 2024, 10 (04): : 129 - 140
  • [33] DC Arc Fault Detection Method Based on Weighted Differential Current
    Di, Zhenguo
    Xiong, Qing
    Zhang, Chen
    Li, Rui
    Ji, Shengchang
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (05): : 141 - 148
  • [34] Practical method for evaluating ground fault current distribution in station, towers and ground wire
    Popovic, LM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (01) : 123 - 128
  • [35] AN ARC METHOD FOR SAMPLE TRANSFER IN SPECTROCHEMICAL ANALYSIS
    LEISTNER, CJ
    SPECTROCHIMICA ACTA, 1958, 10 (03): : 331 - 331
  • [36] AN ARC METHOD FOR SAMPLE TRANSFER IN SPECTROCHEMICAL ANALYSIS
    LEISTNER, CJ
    SPECTROCHIMICA ACTA, 1957, 9 (04): : 361 - 361
  • [37] A Novel Selective Earth Fault Detection Method Using Residual Current
    Dong, Xinzhou
    Cui, Tao
    Bo, Zhiqian
    Juszczyk, Andrzej
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 192 - +
  • [38] On Line Current Monitoring and Application of a Residual Method for Eccentricity Fault Detection
    Metatla, Abderrezak
    Benzahioul, Samia
    Bahi, Tahar
    Lefebvre, Dimitri
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2011, 11 (01) : 69 - 72
  • [39] Active Arc Suppression Algorithm for Generator Stator Winding Ground Fault in the Floating Nuclear Power Plant
    Wang, Yikai
    Yin, Xianggen
    Xu, Wen
    Qiao, Jian
    Tan, Liming
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (06) : 5356 - 5365
  • [40] Arc Suppression Control With Adaptive Parameters of Active Grounding Device Considering Ground Fault Resistance Uncertainty
    Luan, Xiaoming
    Li, Xiaopeng
    Wu, Shouyuan
    Jia, Chunjuan
    Mei, Hongkun
    Gao, Lixue
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (01) : 426 - 435