Residual current analysis by applying ground fault transfer arc suppression method

被引:2
|
作者
Yu X. [1 ,2 ]
Ouyang J. [1 ,3 ]
Qin L. [1 ,3 ]
机构
[1] Electric Power Research Institute of Guangxi Power Grid, Nanning
[2] Hohai University, Guangxi electric power research institute
[3] Guangxi University, Guangxi electric power research institute
来源
关键词
Arc extinction; Ground fault transfer; Isolated neutral system; Residual current; Single-phase grounding fault;
D O I
10.6329/CIEE.201812_25(6).0001
中图分类号
学科分类号
摘要
When a single-phase grounding fault occurs in isolated neutral systems, ground fault transfer, which makes the fault phase directly ground on the bus, can effectively inhibit the intermittent arc overvoltage. However, the influence of this method on residual current and arc extinction lacks essential investigation and validation. In this paper, distribution characteristics of the capacitive current of each feeder and the load current of fault feeder are analyzed. After ground fault transfer, expressions of the residual current at fault point and the current at bus grounding point are given. Then, the variations of residual current with fault location and transition resistance are analyzed. It can be found that the residual current might be enlarged and even exceed the system capacitive current, because part of the load current of fault feeder passes through the bus grounding point, the earth or the cable sheath and the fault point to the load. It is difficult for arc to extinguish. Therefore, phase-to-phase fault would be caused and personal security even be endangered. Finally, the correctness of theoretic analysis is verified by simulations. © 2018, Chinese Institute of Electrical Engineering. All rights reserved.
引用
收藏
页码:205 / 214
页数:9
相关论文
共 50 条
  • [21] Analysis of Arc Suppression Performance of Active Transfer Type Arc Extinguishing Device
    Liu Jian
    Tian Xiaozhuo
    Li Yunge
    Zhang Zhihua
    Lei Yu
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3614 - 3619
  • [22] Ground fault line selection with improved residual flow incremental method
    Li, W. (liwenhong110@163.com), 1600, Universitas Ahmad Dahlan, Jalan Kapas 9, Semaki, Umbul Harjo,, Yogiakarta, 55165, Indonesia (11):
  • [23] DC-link voltage control method of a fault phase bridge arm transfer grounding arc suppression device
    Guo, Moufa
    Liu, Xinbin
    Zhang, Binlong
    Zhao, Guojun
    Zheng, Zeyin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (19): : 1 - 14
  • [24] Conditions for Effective Ground Fault Suppression in Distribution Networks With Capacitive Current Compensation
    Shirkovets, Andrey I.
    Telegin, Andrey V.
    Kochura, Danila V.
    10TH INTERNATIONAL CONFERENCE 2016 ELECTRIC POWER QUALITY AND SUPPLY RELIABILITY CONFERENCE (PQ), 2016, : 301 - 307
  • [25] Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
    Artale, Giovanni
    Cataliotti, Antonio
    Cosentino, Valentina
    Di Cara, Dario
    Nuccio, Salvatore
    Tine, Giovanni
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (05) : 888 - 896
  • [26] Fault current suppression method for distribution network by controlling IIDG current phase
    Li H.
    Peng K.
    Zhang X.
    Liu J.
    Xu B.
    Zhao Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (09): : 180 - 186
  • [27] Hybrid Model for Analysis of Ground Fault Current Distribution
    Vujevic, S.
    Balaz, Z.
    Modric, T.
    Sarajcev, P.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (02): : 4035 - 4045
  • [28] GROUND-FAULT-ARC SUPPRESSION ON SERIES-COMPENSATED AND SHUNT-COMPENSATED LINES
    ASHOKKUM.BS
    PARTHASARATHY, K
    KOTHARI, GC
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1972, 119 (11): : 1650 - +
  • [29] Review of Flexible Arc Suppression Technology for Single-phase-to-ground Fault in Distribution Networks
    Guo M.
    You J.
    Zheng Z.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (10): : 4232 - 4246
  • [30] Sensitive ground fault detection in compensated systems (arc suppression coil). What is influencing the sensitivity?
    Kaufmann, Gerd
    Vaitkevicius, Ramunas
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 971 - 977