Simplified calculation for grounding resistance of transmission tower

被引:0
|
作者
Li, Tianwei [1 ]
He, Min [1 ]
Lu, Benchu [1 ]
Cheng, Siyong [1 ]
机构
[1] Guangxi Electric Power Industry Investigation Design and Research Institute, Nanning 530023, Guangxi Zhuang Autonomous Region, China
来源
关键词
Electric grounding - Towers - Electric power transmission;
D O I
暂无
中图分类号
学科分类号
摘要
In the grounding design of high voltage transmission line the empirical formula is often used to calculate the grounding resistance of transmission tower, so the calculation accuracy is just passable. Considering the non-uniformity of the current dispersed from the grounding electrode, a grounding electrode is divided into sections to calculate their self-resistance coefficients and mutual resistance coefficients, thus the grounding resistance of grounding electrode is solved. The number of conductor sections is dependent upon the requirement to computation accuracy, the more the number of the sections, the higher the computational accuracy. Finally, the grounding resistances of grounding electrode usually used for transmission tower, such as radial grounding electrode and double-ring grounding electrode, under different soil resistivity, conductor radii and depths of burying are analyzed.
引用
收藏
页码:170 / 175
相关论文
共 50 条
  • [41] Research on New Grounding Technology of Transmission Line Tower in Karst Area
    Liu, Sanwei
    Sima, Wenxia
    Yuan, Tao
    Yang, Qing
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1154 - 1157
  • [42] Some Notes on the Impulse Characteristics of Type A Grounding of Transmission Line Tower
    Bajramovic, Z.
    Mujezinovic, A.
    Turkovic, I.
    Avdakovic, S.
    Carsimamovic, S.
    Veledar, M.
    2017 2ND INTERNATIONAL MULTIDISCIPLINARY CONFERENCE ON COMPUTER AND ENERGY SCIENCE (SPLITECH), 2017, : 255 - 260
  • [43] Influence of transmission line tower grounding impedance to the line flashover rate
    Stojkovic, Z
    Savic, MS
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1999, 9 (04): : 261 - 270
  • [44] Effects of transmission line tower grounding improvements on its lightning performance
    Diaz, Luis
    Grange, Francois
    Journet, Sebastien
    Dawalibi, Farid
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [45] A simplified method for calculating the impulse resistance of vertical grounding rods
    Zhang, XQ
    2002 IEEE REGION 10 CONFERENCE ON COMPUTERS, COMMUNICATIONS, CONTROL AND POWER ENGINEERING, VOLS I-III, PROCEEDINGS, 2002, : 1881 - 1884
  • [46] Calculation of the Grounding Resistance of Structures Located on Elevated Terrain
    Sunjerga, Antonio
    Rachidi, Farhad
    Rubinstein, Marcos
    Poljak, Dragan
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2019, 61 (06) : 1891 - 1895
  • [48] Tower impulse grounding resistance measurement based on multiple frequency impedance
    Dan, Yihua
    Zhang, Ruixuan
    Wu, Yongye
    Li, Yiqiao
    Wang, Xuement
    Yang, Jian
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (15) : 3488 - 3500
  • [49] A multi-frequency sweeping method of measuring tower grounding resistance
    Zhang, Zhanlong
    Xu, Xiao
    Liu, Cheng
    Chen, Liang
    Dong, Min
    Liu, Guohua
    Zhu, Yunxiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (19): : 5078 - 5086
  • [50] Choosing configurations of transmission line tower grounding by back flashover probability value
    Kuklin, Dmitry
    FRONTIERS IN ENERGY, 2016, 10 (02) : 213 - 226