Simplified calculation for grounding resistance of transmission tower

被引:0
|
作者
Li, Tianwei [1 ]
He, Min [1 ]
Lu, Benchu [1 ]
Cheng, Siyong [1 ]
机构
[1] Guangxi Electric Power Industry Investigation Design and Research Institute, Nanning 530023, Guangxi Zhuang Autonomous Region, China
来源
关键词
Electric grounding - Towers - Electric power transmission;
D O I
暂无
中图分类号
学科分类号
摘要
In the grounding design of high voltage transmission line the empirical formula is often used to calculate the grounding resistance of transmission tower, so the calculation accuracy is just passable. Considering the non-uniformity of the current dispersed from the grounding electrode, a grounding electrode is divided into sections to calculate their self-resistance coefficients and mutual resistance coefficients, thus the grounding resistance of grounding electrode is solved. The number of conductor sections is dependent upon the requirement to computation accuracy, the more the number of the sections, the higher the computational accuracy. Finally, the grounding resistances of grounding electrode usually used for transmission tower, such as radial grounding electrode and double-ring grounding electrode, under different soil resistivity, conductor radii and depths of burying are analyzed.
引用
收藏
页码:170 / 175
相关论文
共 50 条
  • [1] Quick calculation of the grounding resistance of a typical 110 kV transmission line tower grounding system
    Trifunovic, J.
    Kostic, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 131 : 178 - 186
  • [2] Study on Resistance Reduction Efficiency of Grounding Module in Transmission Tower Grounding Grid
    Zhao, Wenlong
    Hu, Yuanchao
    Chen, Jiajia
    Jing, Dong
    Gao, Xiaojing
    Jiang, Zhipeng
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 103 - 107
  • [3] Calculation and analysis of grounding body of typical tower foundation for UHV power transmission
    Pan, Wenxia
    Wang, Bing
    Quan, Rui
    Dai, Min
    Tong, Xuefang
    Gu, Dingxie
    Dianwang Jishu/Power System Technology, 2013, 37 (03): : 679 - 685
  • [4] METHOD OF ESTIMATING THE GROUNDING RESISTANCE OF POWER TRANSMISSION TOWER FOUNDATION.
    Noda, Masanobu
    Kinoshita, Hitoshi
    Matsubara, Ichiro
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1987, 107 (04): : 68 - 76
  • [5] Optimization Research on Grounding Resistance of Power Transmission Line Tower Foundation
    Xiang, Zhen
    Li, Xun
    Chen, Xiao
    Lv, Qishen
    Zhang, Chengwei
    Ai, Jingwen
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 82 - 86
  • [6] Fitting algorithm of transmission tower grounding resistance in vertically layered soil models
    Tang, Bo
    Huang, Ying
    Liu, Ren
    Wu, Zhuo
    Qu, Zihang
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 139 : 121 - 126
  • [7] Power Frequency Interference and Suppression in Measurement of Power Transmission Tower Grounding Resistance
    Zhou, Wenjun
    Liu, Yushun
    Li, Gongxin
    Yan, Guozhi
    Yang, Shuai
    Li, Han
    Zhou, Chengke
    Su, Charles Qi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 1016 - 1023
  • [8] CALCULATION OF GROUNDING RESISTANCE
    CHEN, CX
    ELECTRIC POWER SYSTEMS RESEARCH, 1984, 7 (01) : 29 - 37
  • [9] ECONOMIC OPTIMIZATION OF TRANSMISSION TOWER GROUNDING AND INSULATION
    GROSSER, GE
    HILEMAN, AR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (08): : 979 - &
  • [10] Application of tower grounding device equivalent model in the calculation of transmission line back-flashover
    Chen, Huaifei
    Cai, Hansheng
    Ni, Yang
    Jia, Lei
    Lu, Hailiang
    Liu, Gang
    Lan, Lei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1830 - 1835