Patient-specific aortic phantom with tunable compliance

被引:5
|
作者
Gallarello, Antonio [1 ]
Palombi, Andrea [2 ]
Annio, Giacomo [2 ]
Homer-Vanniasinkam, Shervanthi [3 ]
de Momi, Elena [1 ]
Maritati, Gabriele [4 ]
Torii, Ryo [2 ]
Burriesci, Gaetano [2 ,5 ]
Wurdemann, Helge A. [2 ]
机构
[1] Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano,20133, Italy
[2] Department of Mechanical Engineering, University College, London,WC1E 7JE, United Kingdom
[3] Leeds Vascular Institute, Leeds General Infirmary, Leeds,LS1 3EX, United Kingdom
[4] Vascular and Endovascular Unit, Perrino Hospital, ASL-Br, Brindisi,72100, Italy
[5] Ri.MED Foundation, Via Bandiera 11, Palermo,90133, Italy
基金
英国工程与自然科学研究理事会;
关键词
Computerized tomography - Magnetic resonance imaging - Elastic moduli - Arches - Blood vessels - Medical imaging - Silicones;
D O I
10.1115/1.4044611
中图分类号
学科分类号
摘要
Validation of computational models using in vitro phantoms is a nontrivial task, especially in the replication of the mechanical properties of the vessel walls, which varies with age and pathophysiological state. In this paper, we present a novel aortic phantom reconstructed from patient-specific data with variable wall compliance that can be tuned without recreating the phantom. The three-dimensional (3D) geometry of an aortic arch was retrieved from a computed tomography angiography scan. A rubber-like silicone phantom was manufactured and connected to a compliance chamber in order to tune its compliance. A lumped resistance was also coupled with the system. The compliance of the aortic arch model was validated using the Young's modulus and characterized further with respect to clinically relevant indicators. The silicone model demonstrates that compliance can be finely tuned with this system under pulsatile flow conditions. The phantom replicated values of compliance in the physiological range. Both, the pressure curves and the asymmetrical behavior of the expansion, are in agreement with the literature. This novel design approach allows obtaining for the first time a phantom with tunable compliance. Vascular phantoms designed and developed with the methodology proposed in this paper have high potential to be used in diverse conditions. Applications include training of physicians, pre-operative trials for complex interventions, testing of medical devices for cardiovascular diseases (CVDs), and comparative Magnetic-resonance-imaging (MRI)-based computational studies. Copyright © 2019 by ASME
引用
收藏
相关论文
共 50 条
  • [41] Evaluation of a Patient-Specific Respiratory Motion Model in Thoracic and Abdominal Phantom and Patient CT Images
    Liu, F.
    Zhang, Q.
    Hu, Y.
    Goodman, K.
    Mageras, G.
    MEDICAL PHYSICS, 2012, 39 (06) : 3912 - 3912
  • [42] Pseudo In Vivo Patient Dosimetry Using a 3D-Printed Patient-Specific Phantom
    Ger, R.
    Burgett, E. A.
    Price, R. R.
    Craft, D. F.
    Kry, S. F.
    Howell, R. M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3667 - 3668
  • [43] A 3-D-PRINTED PATIENT-SPECIFIC ULTRASOUND PHANTOM FOR FAST SCAN
    Al-Zogbi, Lidia
    Bock, Brian
    Schaffer, Saul
    Fleiter, Thorsten
    Krieger, Axel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03): : 820 - 832
  • [44] Patient-specific templates for image-guided intervention-a phantom study
    Venturi, David
    Glossop, Neil
    Bale, Reto
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2020, 29 (05) : 251 - 260
  • [45] Patient-Specific Vascular Flow Phantom for MRI- and Doppler Ultrasound Imaging
    Soloukey, Sadaf
    Generowicz, Bastian
    Warnert, Esther
    Springeling, Geert
    Schouten, Joost
    De Zeeuw, Chris
    Dirven, Clemens
    Vincent, Arnaud
    Kruizinga, Pieter
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (06): : 860 - 868
  • [46] Patient-specific neurosurgical phantom: assessment of visual quality, accuracy, and scaling effects
    Felipe Wilker Grillo
    Victor Hugo Souza
    Renan Hiroshi Matsuda
    Carlo Rondinoni
    Theo Zeferino Pavan
    Oswaldo Baffa
    Helio Rubens Machado
    Antonio Adilton Oliveira Carneiro
    3D Printing in Medicine, 4 (1)
  • [47] Patient-Specific 3D Printed Models of Aortic Aneurysm and Aortic Dissection
    Sun, Zhonghua
    Squelch, Andrew
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (04) : 886 - 889
  • [48] Patient-specific Ascending Thoracic Aortic Aneurysm Wall Stress Can Be Accurately Estimated Without Patient-specific Wall Material Properties
    Wang, Zhongjie
    Xuan, Yue
    Haraldsson, Henrik
    Hope, Michael D.
    Saloner, David A.
    Guccione, Julius M.
    Ge, Liang
    Tseng, Elaine E.
    CIRCULATION, 2017, 136
  • [49] Effects of Pulsatile Fatigue on In Situ Antegrade Fenestrated Polyester Stent Grafts Deployed in a Patient-Specific Phantom Model of Juxtarenal Aortic Aneurysm
    Ruthrauff, Alicia A.
    King, Martin W.
    Soulez, Gilles
    Tan, Kong T.
    Crawford, Sean A.
    Roche-Nagle, Graham
    Cloutier, Guy
    Tse, Leonard W.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (10) : 1551 - 1558
  • [50] On the prospect of patient-specific biomechanics without patient-specific properties of tissues
    Miller, Karol
    Lu, Jia
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 27 : 154 - 166