Patient-specific aortic phantom with tunable compliance

被引:5
|
作者
Gallarello, Antonio [1 ]
Palombi, Andrea [2 ]
Annio, Giacomo [2 ]
Homer-Vanniasinkam, Shervanthi [3 ]
de Momi, Elena [1 ]
Maritati, Gabriele [4 ]
Torii, Ryo [2 ]
Burriesci, Gaetano [2 ,5 ]
Wurdemann, Helge A. [2 ]
机构
[1] Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milano,20133, Italy
[2] Department of Mechanical Engineering, University College, London,WC1E 7JE, United Kingdom
[3] Leeds Vascular Institute, Leeds General Infirmary, Leeds,LS1 3EX, United Kingdom
[4] Vascular and Endovascular Unit, Perrino Hospital, ASL-Br, Brindisi,72100, Italy
[5] Ri.MED Foundation, Via Bandiera 11, Palermo,90133, Italy
基金
英国工程与自然科学研究理事会;
关键词
Computerized tomography - Magnetic resonance imaging - Elastic moduli - Arches - Blood vessels - Medical imaging - Silicones;
D O I
10.1115/1.4044611
中图分类号
学科分类号
摘要
Validation of computational models using in vitro phantoms is a nontrivial task, especially in the replication of the mechanical properties of the vessel walls, which varies with age and pathophysiological state. In this paper, we present a novel aortic phantom reconstructed from patient-specific data with variable wall compliance that can be tuned without recreating the phantom. The three-dimensional (3D) geometry of an aortic arch was retrieved from a computed tomography angiography scan. A rubber-like silicone phantom was manufactured and connected to a compliance chamber in order to tune its compliance. A lumped resistance was also coupled with the system. The compliance of the aortic arch model was validated using the Young's modulus and characterized further with respect to clinically relevant indicators. The silicone model demonstrates that compliance can be finely tuned with this system under pulsatile flow conditions. The phantom replicated values of compliance in the physiological range. Both, the pressure curves and the asymmetrical behavior of the expansion, are in agreement with the literature. This novel design approach allows obtaining for the first time a phantom with tunable compliance. Vascular phantoms designed and developed with the methodology proposed in this paper have high potential to be used in diverse conditions. Applications include training of physicians, pre-operative trials for complex interventions, testing of medical devices for cardiovascular diseases (CVDs), and comparative Magnetic-resonance-imaging (MRI)-based computational studies. Copyright © 2019 by ASME
引用
收藏
相关论文
共 50 条
  • [21] Feasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy
    Yea, Ji Woon
    Park, Jae Won
    Kim, Sung Kyu
    Kim, Dong Youn
    Kim, Jae Gu
    Seo, Chan Young
    Jeong, Won Hyo
    Jeong, Man Youl
    Oh, Se An
    PLOS ONE, 2017, 12 (07):
  • [22] Patient-Specific Haemodynamic Analysis of Virtual Grafting Strategies in Type-B Aortic Dissection: Impact of Compliance Mismatch
    Girardin, Louis
    Stokes, Catriona
    Thet, Myat Soe
    Oo, Aung Ye
    Balabani, Stavroula
    Diaz-Zuccarini, Vanessa
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (03) : 290 - 304
  • [23] TOWARDS PATIENT-SPECIFIC MODELING OF AN ENLARGING ABDOMINAL AORTIC ANEURYSM
    Zeinali-Davarani, S.
    Sheidaei, A.
    Baek, S.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 509 - 510
  • [24] Fluid–structure interaction simulations of patient-specific aortic dissection
    Kathrin Bäumler
    Vijay Vedula
    Anna M. Sailer
    Jongmin Seo
    Peter Chiu
    Gabriel Mistelbauer
    Frandics P. Chan
    Michael P. Fischbein
    Alison L. Marsden
    Dominik Fleischmann
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 1607 - 1628
  • [25] Patient-specific isogeometric structural analysis of aortic valve closure
    Morganti, S.
    Auricchio, F.
    Benson, D. J.
    Gambarin, F. I.
    Hartmann, S.
    Hughes, T. J. R.
    Reali, A.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2015, 284 : 508 - 520
  • [26] Patient-specific simulations of transcatheter aortic valve stent implantation
    Capelli, C.
    Bosi, G. M.
    Cerri, E.
    Nordmeyer, J.
    Odenwald, T.
    Bonhoeffer, P.
    Migliavacca, F.
    Taylor, A. M.
    Schievano, S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (02) : 183 - 192
  • [27] Study of Effect of Boundary Conditions on Patient-Specific Aortic Hemodynamics
    Chi, Qingzhuo
    Chen, Huimin
    Yang, Shiqi
    Mu, Lizhong
    Ji, Changjin
    He, Ying
    Luan, Yong
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2022, 131 (01): : 31 - 47
  • [28] Towards patient-specific risk assessment of abdominal aortic aneurysm
    M. Breeuwer
    S. de Putter
    U. Kose
    L. Speelman
    K. Visser
    F. Gerritsen
    R. Hoogeveen
    R. Krams
    H. van den Bosch
    J. Buth
    T. Gunther
    B. Wolters
    E. van Dam
    F. van de Vosse
    Medical & Biological Engineering & Computing, 2008, 46 : 1085 - 1095
  • [29] A Novel Patient-Specific Human Cardiovascular System Phantom (HCSP) for Reconstructions of Pulsatile Blood Hemodynamic Inside Abdominal Aortic Aneurysm
    Polanczyk, Andrzej
    Podgorski, Michal
    Polanczyk, Maciej
    Piechota-Polanczyk, Aleksandra
    Neumayer, Christoph
    Stefanczyk, Ludomir
    IEEE ACCESS, 2018, 6 : 61896 - 61903
  • [30] Patient-Specific Biomechanics in Marfan Ascending Thoracic Aortic Aneurysms
    Xuan, Yue
    D'Souza, Sara N.
    Wang, Zhongjie
    Pierre, Alejandro Suarez
    Lawton, Jennifer S.
    Ge, Liang
    Tseng, Elaine E.
    ANNALS OF THORACIC SURGERY, 2022, 114 (04): : 1367 - 1375