Influence of supply temperature and booster technology on the energetic performance and levelized cost of heat of a district heating network with central heat pump

被引:0
|
作者
Degelin, A. [1 ,2 ]
Tassenoy, R. [1 ]
Vieren, E. [1 ]
Demeester, T. [1 ]
T'Jollyn, I. [2 ]
De Paepe, M. [1 ,3 ,4 ]
机构
[1] Univ Ghent, Dept Electromech Syst & Met Engn, Sint Pietersnieuwstr 41, B-9000 Ghent, Belgium
[2] Univ Antwerp, Fac Appl Engn, EMIB, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
[3] UGent, FlandersMake, Core Lab MIRO, B-9000 Ghent, Belgium
[4] Univ Cape Town, Dept Mech Engn, Private Bag X3, ZA-7701 Rondebosch, South Africa
关键词
Low-temperature district heating; Central heat pump; Booster heat pump; Modelica; Energy system analysis; Levelized cost of heat; BUILDINGS; SYSTEM; FRICTION; IMPACT;
D O I
10.1016/j.energy.2024.133589
中图分类号
O414.1 [热力学];
学科分类号
摘要
The development of new low-temperature district heating networks in existing urban areas can accelerate the replacement of fossil-fuel-based heating systems by collective heating using electricity or renewable heat sources. Buildings can either be connected to the network in their current, non-refurbished state for rapid deployment or be refurbished before connection to achieve maximum energy efficiency. To assess the difference between these two strategies, this paper examines eight low-temperature district heating concepts with central heat pump, comparing their energy use and levelized cost of heat. The study includes four scenarios for each strategy, considering supply temperatures ranging from 10 degrees C to 75 degrees C. Heat pumps or electric heaters are used as booster technology when the network supply temperature is too low for space heating or domestic hot water purposes. The use of booster heat pumps shows the highest seasonal coefficient of performance for both refurbished (4.61) and non-refurbished buildings (3.43). However, booster technologies result in the highest levelized cost of heat, driven mainly by the high investment cost of the network and booster units. Lowest levelized cost of heat of 213 <euro>/MWhth is obtained for non-refurbished buildings at 75 degrees C and 297 <euro>/MWhth for refurbished buildings at 55 degrees C without boosters.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] On the influence of heat cost allocation on operation of heating system in buildings and possible, additional decrease of supply temperature
    Cholewa, Tomasz
    Dell'Isola, Marco
    Canale, Laura
    Ficco, Giorgio
    Michnikowski, Pawel
    Siuta-Olcha, Alicja
    Olszewska, Aleksandra
    Sadowska, Gabriela
    Dudzinska, Marzenna R.
    ENERGY AND BUILDINGS, 2022, 254
  • [42] CO2 Heat Pump in High-Temperature District Heating Plant
    Eggen, G.
    Skinnes, K.
    Engen, M.
    Ingebrigtsen, M.
    Smedegard, O. O.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 510 - 515
  • [43] Influence of Different Operating Conditions of a District Heating and Cooling System on Heat Transportation Losses of a District Heating Network
    Zwierzchowski, Ryszard
    Niemyjski, Olgierd
    3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018), 2019, 471
  • [44] Performance analysis of air source heat pump space heating system with an adaptive control for supply water temperature
    Sun, Yuying
    Chen, Xu
    Wu, Shangjiang
    Wei, Wenzhe
    Wang, Wei
    Deng, Shiming
    APPLIED THERMAL ENGINEERING, 2022, 211
  • [45] Use of Absorption Heat Pumps to Raise District Cooling Waste Heat Temperature for District Heating Supply in Tallinn: Technical and Economic Analysis
    Kirs, Tanel
    Sukumaran, Sreenath
    Latosov, Eduard
    Volkova, Anna
    ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2024, 28 (01) : 409 - 421
  • [46] Thermodynamic analysis and performance assessment of an integrated heat pump system for district heating applications
    Soltani, Reza
    Dincer, Ibrahim
    Rosen, Marc A.
    APPLIED THERMAL ENGINEERING, 2015, 89 : 833 - 842
  • [47] Influence of desorption temperature on the thermodynamic performance of adsorption heat pump
    Zwarycz-Makles, Katarzyna
    17TH INTERNATIONAL CONFERENCE HEAT TRANSFER AND RENEWABLE SOURCES OF ENERGY (HTRSE-2018), 2018, 70
  • [48] Performance analysis of a reversible water/LiBr absorption heat pump connected to district heating network in warm and cold climates
    Ayou, Dereje S.
    Wardhana, Muhammad Fa'iq Vidi
    Coronas, Alberto
    ENERGY, 2023, 268
  • [49] Technology and Economic Analysis of Sewage Source Heat Pump Combined Type District Heating Method
    Zhang Qunli
    Qian, Nie
    Fang, Liu
    Yin Chaohui
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1312 - 1318
  • [50] Research progress on the fifth-generation district heating system based on heat pump technology
    Gong, Yuexuan
    Ma, Guoyuan
    Jiang, Yuepeng
    Wang, Lei
    JOURNAL OF BUILDING ENGINEERING, 2023, 71