Experimental study of a closed loop pulsating heat pipe aiming at assessing the optimized operational conditions

被引:0
|
作者
Samadi M. [1 ]
Zarenezhad B. [1 ]
机构
[1] Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan
来源
Zarenezhad, Bahman (bzarenezhad@semnan.ac.ir) | 1600年 / Budapest University of Technology and Economics卷 / 60期
关键词
Dry-out; Filling ratio; Heat exchanger; Pulsating heat pipe; Vacuum;
D O I
10.3311/PPme.8703
中图分类号
学科分类号
摘要
In recent times pulsating heat pipes turn into a pleasing field of study for researchers as useful devices to enhance and intensify heat transfer. Experimental data under various operating conditions for a better theoretical understanding are needed. This paper presents an experimental study on a closed loop pulsating heat pipe made of copper with 14 U-turns. The experiments were carried out for different working fluids (acetone, distilled water, ethanol and methanol) and their mixing, heat input, filling ratio and evacuation levels to optimize operational conditions. Thermal resistance at steady state specified for performance evaluation and showed better results for acetone. The mentioned working fluids in filling ratio of 60 % have better operation and acetone has the best. As well as experiments in different evacuation levels showed, more evacuation lead to more performance.
引用
收藏
页码:96 / 102
页数:6
相关论文
共 50 条
  • [41] Effect of nanofluids on thermal performance of closed loop pulsating heat pipe
    Karthikeyan, V. K.
    Ramachandran, K.
    Pillai, B. C.
    Solomon, A. Brusly
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 54 : 171 - 178
  • [42] Investigation on the performance of closed-loop pulsating heat pipe with surfactant
    Wang, Jiansheng
    Xie, Jinyuan
    Liu, Xueling
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [43] Predicting thermal instability in a closed loop pulsating heat pipe system
    Chen, Ping-Hei
    Lee, Ya-Wei
    Chang, Tien-Li
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1566 - 1576
  • [44] Thermal performance of an open loop closed end pulsating heat pipe
    Manabendra Saha
    C. M. Feroz
    F. Ahmed
    T. Mujib
    Heat and Mass Transfer, 2012, 48 : 259 - 265
  • [45] Analysis of Closed Loop Pulsating Heat Pipe using optimisation techniques
    SanthiSree, N.
    Sudheer, N. V. V. S.
    Bhramara, P.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 43 (01) : 2824 - 2833
  • [46] Thermal performance of an open loop closed end pulsating heat pipe
    Saha, Manabendra
    Feroz, C. M.
    Ahmed, F.
    Mujib, T.
    HEAT AND MASS TRANSFER, 2012, 48 (02) : 259 - 265
  • [47] EXPERIMENTAL CHARACTERIZATION OF AN OPEN LOOP PULSATING HEAT PIPE COOLER
    Torresin, Daniele
    Habert, Mathieu
    Agostini, Francesco
    Agostini, Bruno
    Mounier, Violette
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2014, 2014,
  • [48] Thermal Performance of a Closed-Loop Pulsating Heat Pipe With Multiple Heat Sources
    Kammuang-Lue, Niti
    Sakulchangsatjatai, Phrut
    Terdtoon, Pradit
    HEAT TRANSFER ENGINEERING, 2014, 35 (13) : 1161 - 1172
  • [49] Visual study on flow and operational characteristics of flat plate closed loop pulsating heat pipes
    College of Environmental Science and Engineering, Donghua University, Shanghai 201620, China
    不详
    不详
    J. Donghua Univ., 2009, 1 (80-84):
  • [50] Visual Study on Flow and Operational Characteristics of Flat Plate Closed Loop Pulsating Heat Pipes
    杨洪海
    Groll Manfred
    Khandekar Sameer
    JournalofDonghuaUniversity(EnglishEdition), 2009, 26 (01) : 80 - 84