Experimental study of a closed loop pulsating heat pipe aiming at assessing the optimized operational conditions

被引:0
|
作者
Samadi M. [1 ]
Zarenezhad B. [1 ]
机构
[1] Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan
来源
Zarenezhad, Bahman (bzarenezhad@semnan.ac.ir) | 1600年 / Budapest University of Technology and Economics卷 / 60期
关键词
Dry-out; Filling ratio; Heat exchanger; Pulsating heat pipe; Vacuum;
D O I
10.3311/PPme.8703
中图分类号
学科分类号
摘要
In recent times pulsating heat pipes turn into a pleasing field of study for researchers as useful devices to enhance and intensify heat transfer. Experimental data under various operating conditions for a better theoretical understanding are needed. This paper presents an experimental study on a closed loop pulsating heat pipe made of copper with 14 U-turns. The experiments were carried out for different working fluids (acetone, distilled water, ethanol and methanol) and their mixing, heat input, filling ratio and evacuation levels to optimize operational conditions. Thermal resistance at steady state specified for performance evaluation and showed better results for acetone. The mentioned working fluids in filling ratio of 60 % have better operation and acetone has the best. As well as experiments in different evacuation levels showed, more evacuation lead to more performance.
引用
收藏
页码:96 / 102
页数:6
相关论文
共 50 条
  • [21] Experimental study of thermal performance in a closed loop pulsating heat pipe with alternating superhydrophobic channels
    Betancur, Luis
    Mangini, Daniele
    Mantelli, Marcia
    Marengo, Marco
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 17
  • [22] Operational limit of closed loop pulsating heat pipes
    Yang, Honghai
    Khandekar, S.
    Groll, M.
    APPLIED THERMAL ENGINEERING, 2008, 28 (01) : 49 - 59
  • [23] Experimental Investigations for Start Up and Maximum Heat Load of Closed Loop Pulsating Heat Pipe
    Sarangi, R. K.
    Rane, M. V.
    CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 683 - 687
  • [24] Experimental study of a closed loop flat plate pulsating heat pipe under a varying gravity force
    Ayel, V.
    Araneo, L.
    Scalambra, A.
    Mameli, M.
    Romestant, C.
    Piteau, A.
    Marengo, M.
    Filippeschi, S.
    Bertin, Y.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 96 : 23 - 34
  • [25] Experimental Investigation of a Flat-Plate Closed-Loop Pulsating Heat Pipe
    Wits, Wessel W.
    Groeneveld, Gerben
    van Gerner, Henk Jan
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2019, 141 (09):
  • [26] An experimental investigation on the effect of fin in the performance of closed loop pulsating heat pipe (CLPHP)
    Rahman, M. Lutfor
    Sultan, Rasel A.
    Islam, T.
    Hasan, Noor M.
    Ali, Mohammad
    6TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2015, 105 : 137 - 144
  • [27] Experimental Investigation and Performance Evaluation of a Multi turn Closed Loop Pulsating Heat Pipe
    Babu, Narendra N.
    Naik, Rudra
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 1554 - 1558
  • [28] Experimental Investigation of Aluminum Oxide Nanofluid on Closed Loop Pulsating Heat Pipe Performance
    Venkataramana, P.
    Vijayakumar, P.
    Balakrishna, B.
    JOURNAL OF APPLIED FLUID MECHANICS, 2022, 15 (06) : 1947 - 1955
  • [29] Experimental Investigation of Thermal Resistance of a Ferrofluidic Closed-Loop Pulsating Heat Pipe
    Mohammadi, Maziar
    Mohammadi, Mohammad
    Ghahremani, Amir R.
    Shafii, Mohammad B.
    Mohammadi, Niloofar
    HEAT TRANSFER ENGINEERING, 2014, 35 (01) : 25 - 33
  • [30] CFD Analysis of Copper Closed Loop Pulsating Heat pipe
    Suresh, J. Venkata
    Bhramara, P.