Experimental study of a closed loop pulsating heat pipe aiming at assessing the optimized operational conditions

被引:0
|
作者
Samadi M. [1 ]
Zarenezhad B. [1 ]
机构
[1] Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan
来源
Zarenezhad, Bahman (bzarenezhad@semnan.ac.ir) | 1600年 / Budapest University of Technology and Economics卷 / 60期
关键词
Dry-out; Filling ratio; Heat exchanger; Pulsating heat pipe; Vacuum;
D O I
10.3311/PPme.8703
中图分类号
学科分类号
摘要
In recent times pulsating heat pipes turn into a pleasing field of study for researchers as useful devices to enhance and intensify heat transfer. Experimental data under various operating conditions for a better theoretical understanding are needed. This paper presents an experimental study on a closed loop pulsating heat pipe made of copper with 14 U-turns. The experiments were carried out for different working fluids (acetone, distilled water, ethanol and methanol) and their mixing, heat input, filling ratio and evacuation levels to optimize operational conditions. Thermal resistance at steady state specified for performance evaluation and showed better results for acetone. The mentioned working fluids in filling ratio of 60 % have better operation and acetone has the best. As well as experiments in different evacuation levels showed, more evacuation lead to more performance.
引用
收藏
页码:96 / 102
页数:6
相关论文
共 50 条
  • [1] Operational regimes in a closed loop pulsating heat pipe
    Spinato, Giulia
    Borhani, Navid
    Thome, John R.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2016, 102 : 78 - 88
  • [2] EXPERIMENTAL INVESTIGATION OF CLOSED LOOP PULSATING HEAT PIPE WITH NANOFLUIDS
    Jamshidi, Hamed
    Arabnejad, Sajad
    Shafii, Mohammad Behshad
    Saboohi, Yadollah
    Rasoulian, Ramin
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 1, 2009, : 675 - 683
  • [3] Thermo-hydrodynamics of closed loop pulsating heat pipe: an experimental study
    Pachghare, Pramod R.
    Mahalle, Ashish M.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (08) : 3387 - 3394
  • [4] Understanding operational regimes of closed loop pulsating heat pipes: an experimental study
    Khandekar, S
    Dollinger, N
    Groll, M
    APPLIED THERMAL ENGINEERING, 2003, 23 (06) : 707 - 719
  • [5] Thermo-hydrodynamics of closed loop pulsating heat pipe: an experimental study
    Pramod R. Pachghare
    Ashish M. Mahalle
    Journal of Mechanical Science and Technology, 2014, 28 : 3387 - 3394
  • [6] Experimental study on start-up performance of closed loop pulsating heat pipe
    Liu X.-D.
    Chen Y.-P.
    Zhang C.-B.
    Shi M.-H.
    Yuhang Xuebao/Journal of Astronautics, 2011, 32 (10): : 2300 - 2304
  • [7] Experimental study on a hydrogen closed-loop pulsating heat pipe with two turns
    Sun, Xiao
    Li, Sizhuo
    Jiao, Bo
    Gan, Zhihua
    Pfotenhauer, John
    CRYOGENICS, 2019, 97 : 63 - 69
  • [8] Study on Circulation Flow in Closed Loop Pulsating Heat Pipe
    Kang, Shung-Wen
    Chan, Chien-Hsuan
    Hsiao, Pai-Chun
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2022, 43 (02): : 79 - 86
  • [9] Study on Circulation Flow in Closed Loop Pulsating Heat Pipe
    Kang, Shung-Wen
    Chan, Chien-Hsuan
    Hsiao, Pai-Chun
    Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao, 2022, 43 (02): : 79 - 86
  • [10] Experimental Study on a Hydrogen Closed Loop Pulsating Heat Pipe with Different Adiabatic Lengths
    Gan, Zhihua
    Sun, Xiao
    Jiao, Bo
    Han, Dongyang
    Deng, Haoren
    Wang, Shunhao
    Pfotenhauer, John M.
    HEAT TRANSFER ENGINEERING, 2019, 40 (3-4) : 205 - 214