Experimental study on an improved direct-contact thermal energy storage container

被引:0
|
作者
He, Shiquan [1 ]
Chen, Zijun [1 ]
Wang, Weilong [2 ]
Chen, Qiliang [1 ]
Tang, Lan [1 ]
Huang, Yuantian [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn & Transportat, Guangzhou 510006, Peoples R China
[2] Sun Yat Sen Univ, Sch Mat Sci & Engn, Guangzhou 510006, Peoples R China
关键词
Heat transfer improvement; Direct-contact; Indirect-contact; Phase change material; Heat storage; PHASE-CHANGE MATERIAL; NUMERICAL-SIMULATION; CHARGING PROCESS; HEAT; PERFORMANCE; ERYTHRITOL; RECOVERY; BEHAVIOR; SHELL; TUBE;
D O I
10.1016/j.est.2024.114201
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Direct-contact thermal energy storage (TES) systems characterized by high heat density and rapid heat transfer rates have been exploited for the collection of industrial waste or surplus heat for subsequent utilization. In order to address blockage issue at the initial stage of charging process, an improved direct-contact TES container was developed by incorporating a double-pipe structure at both the inlet and outlet. Within the container, a U-shaped tube serving as the inner tube was concentrically positioned from the inlet to the outlet. Erythritol was selected as the phase change material (PCM), while heat transfer oil (HTO) functioned as the heat transfer medium during experimentation. During the charging process, hot HTO initially flowed through the U-shaped tube, establishing an indirect contact with the PCM. The high thermal conductivity of the U-shaped tube wall expedited the formation of a flow channel within the solid PCM. The duration of forming flow channel was 6 to 13 min. In the discharging phase, the liquid PCM was segregated into convection and conduction zones. The indirect-contact TES experiments were also conducted in the same container. Comparison between indirect-contact and direct- contact TES were analysed from the aspects of phase change behavior, charging and discharging time with the identical container structure and theoretical heat capacity. Results indicated that the direct-contact TES container exhibited superior heat storage and release rates, with the direct-contact discharging time being approximately a quarter of the indirect-contact duration. The phase change behavior of the PCM was notably influenced by the movement of HTO within the direct-contact storage container.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Experimental investigation of thermal energy storage container of phase change materials for space station
    Xing, Y.M.
    Yuan, X.G.
    Wang, C.H.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2001, 16 (01):
  • [42] Experimental study of compressed air energy storage system with thermal energy storage
    Wang, Sixian
    Zhang, Xuelin
    Yang, Luwei
    Zhou, Yuan
    Wang, Junjie
    ENERGY, 2016, 103 : 182 - 191
  • [43] Experimental study of the characteristics of steam jet pump and effect of mixing section length on direct-contact condensation
    Shah, Ajmal
    Chughtai, Imran Rafiq
    Inayat, Mansoor Hameed
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 58 (1-2) : 62 - 69
  • [44] Energy efficient piezoelectrically actuated transducer for direct-contact ultrasonic drying of fabrics
    Peng, Chang
    Moghaddam, Saeed
    DRYING TECHNOLOGY, 2020, 38 (07) : 879 - 888
  • [45] Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling
    Nikooei, Elnaz
    AuYeung, Nick
    Lima, Iolar
    Tan, Xu
    Benard, Andre
    Abbasi, Bahman
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 52
  • [46] Experimental Evaluation and Kinetic Analysis of Direct-Contact Ultrasonic Fabric Drying Process
    Peng, Chang
    Moghaddam, Saeed
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2021, 13 (02)
  • [47] AN EXPERIMENTAL INVESTIGATION OF OC-OTEC DIRECT-CONTACT CONDENSATION AND EVAPORATION PROCESSES
    SAM, RG
    PATEL, BR
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (01): : 120 - 127
  • [48] Experimental Performance Evaluation of Humidification-Dehumidification System With Direct-Contact Dehumidifier
    Dehghani, Saeed
    Mahmoudi, Farzaneh
    Date, Abhijit
    Akbarzadeh, Aliakbar
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2020, 142 (01):
  • [49] PERFORMANCE OF DIRECT-CONTACT LATENT-HEAT STORAGE UNITS WITH 2 HYDRATED SALTS
    FARID, MM
    KHALAF, AN
    SOLAR ENERGY, 1994, 52 (02) : 179 - 189
  • [50] THERMAL ENERGY STORAGE IN AQUIFERS: EXPERIMENTAL STUDY.
    Molz, Fred J.
    Parr, A.David
    Andersen, Peter F.
    Proceedings of the Intersociety Energy Conversion Engineering Conference, 1979, 1 : 534 - 537