Experimental study on an improved direct-contact thermal energy storage container

被引:0
|
作者
He, Shiquan [1 ]
Chen, Zijun [1 ]
Wang, Weilong [2 ]
Chen, Qiliang [1 ]
Tang, Lan [1 ]
Huang, Yuantian [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn & Transportat, Guangzhou 510006, Peoples R China
[2] Sun Yat Sen Univ, Sch Mat Sci & Engn, Guangzhou 510006, Peoples R China
关键词
Heat transfer improvement; Direct-contact; Indirect-contact; Phase change material; Heat storage; PHASE-CHANGE MATERIAL; NUMERICAL-SIMULATION; CHARGING PROCESS; HEAT; PERFORMANCE; ERYTHRITOL; RECOVERY; BEHAVIOR; SHELL; TUBE;
D O I
10.1016/j.est.2024.114201
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Direct-contact thermal energy storage (TES) systems characterized by high heat density and rapid heat transfer rates have been exploited for the collection of industrial waste or surplus heat for subsequent utilization. In order to address blockage issue at the initial stage of charging process, an improved direct-contact TES container was developed by incorporating a double-pipe structure at both the inlet and outlet. Within the container, a U-shaped tube serving as the inner tube was concentrically positioned from the inlet to the outlet. Erythritol was selected as the phase change material (PCM), while heat transfer oil (HTO) functioned as the heat transfer medium during experimentation. During the charging process, hot HTO initially flowed through the U-shaped tube, establishing an indirect contact with the PCM. The high thermal conductivity of the U-shaped tube wall expedited the formation of a flow channel within the solid PCM. The duration of forming flow channel was 6 to 13 min. In the discharging phase, the liquid PCM was segregated into convection and conduction zones. The indirect-contact TES experiments were also conducted in the same container. Comparison between indirect-contact and direct- contact TES were analysed from the aspects of phase change behavior, charging and discharging time with the identical container structure and theoretical heat capacity. Results indicated that the direct-contact TES container exhibited superior heat storage and release rates, with the direct-contact discharging time being approximately a quarter of the indirect-contact duration. The phase change behavior of the PCM was notably influenced by the movement of HTO within the direct-contact storage container.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Exergy analysis of refrigeration cycle of a direct-contact ice storage system
    Lu, Jia-Cai
    Li, Rui-Yang
    Yu, Hong-Ling
    Shanghai Ligong Daxue Xuebao/Journal of University of Shanghai for Science and Technology, 2001, 23 (04):
  • [32] A STUDY OF SEPARATION BY THE DIRECT-CONTACT MEMBRANE DISTILLATION PROCESS
    TOMASZEWSKA, M
    GRYTA, M
    MORAWSKI, AW
    SEPARATIONS TECHNOLOGY, 1994, 4 (04): : 244 - 248
  • [33] Numerical simulation study on optimizing charging process of the direct contact mobilized thermal energy storage
    Guo, Shaopeng
    Li, Hailong
    Zhao, Jun
    Li, Xun
    Yan, Jinyue
    APPLIED ENERGY, 2013, 112 : 1416 - 1423
  • [34] Heat transfer prediction for a direct contact ice thermal energy storage
    Kiatsiriroat, T
    Vithayasai, S
    Vorayos, N
    Nuntaphan, A
    Vorayos, N
    ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (04) : 497 - 508
  • [35] An energy-efficient method for direct-contact ultrasonic cloth drying
    Peng, Chang
    Momen, Ayyoub M.
    Moghaddam, Saeed
    ENERGY, 2017, 138 : 133 - 138
  • [36] GEOTHERMAL-ENERGY EXTRACTED BY DIRECT-CONTACT HEAT-EXCHANGER
    HOGAN, BJ
    DESIGN NEWS, 1979, 35 (20) : 88 - 89
  • [37] Numerical study on direct-contact condensation of vapor in cold water
    Takase, K
    Ose, Y
    Kunugi, T
    FUSION ENGINEERING AND DESIGN, 2002, 63-64 : 421 - 428
  • [38] Experimental study of thermal energy storage system
    Yang, Bing-Chwen
    Huang, Shr-Hau
    Lin, Hsiang-Hui
    American Society of Mechanical Engineers, Advanced Energy Systems Division (Publication) AES, 2000, 40 : 527 - 529
  • [39] Refrigerant direct-contact seawater desalination utilizing LNG cold energy
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    不详
    Huagong Xuebao, 2008, SUPPL. (204-209):
  • [40] Study of Direct-Contact HfO2/Si Interfaces
    Miyata, Noriyuki
    MATERIALS, 2012, 5 (03) : 512 - 527