Characteristics of X-ray and gamma radiation detectors based on polycrystalline CdTe and CdZnTe films

被引:3
|
作者
Utamuradova Sh.B. [1 ]
Muzafarova S.A. [1 ]
Abdugafurov A.М. [1 ]
Fayzullaev K.M. [1 ]
Naurzalieva E.M. [1 ]
Rakhmanov D.A. [1 ]
机构
[1] Institute of Semiconductor Physics and Microelectronics, the National University of Uzbekistan 20 Yangi Almazar st., Tashkent
来源
Utamuradova, Sh.B. (sh-utamuradova@yandex.ru) | 1600年 / ORION Research-and-Production Association卷
关键词
Dark current; Detector intermediate layer; Energy resolution; Film; Irradiation; Mobility; Radiation; Solid solution; Structure;
D O I
10.51368/1996-0948-2021-4-81-86
中图分类号
学科分类号
摘要
Based on CdTe and CdZnTe detectors a number of promising devices were created, which found their application in metallurgy, in solving the problems of customs control and control of nuclear materials, as well as matrix detectors created for the manufacture of medical devices and devices for space research. Detectors, created on the basis of polycrystalline semiconductor CdTe and CdZnTe films with a columnar structure on a molybdenum substrate with a thickness d = 30/150 μm, had a specific resistance P > 105108 Ω-cm. The energy resolution of the CdTe and CdZnTe detectors at room temperature reached ~ 5 keV on the 59.6 keV 241Am line. © Утамурадова Ш. Б., Музафарова С. А., Абдугафуров А. М., Файзуллаев К. М., Наурзалиева Э. М., Рахманов Д. А., 2021
引用
收藏
页码:81 / 86
页数:5
相关论文
共 50 条
  • [31] Uncooled CdTe and CdZnTe Based Detectors for γ-Radiation Spectrometry
    I. M. Gazizov
    A. A. Smirnov
    V. G. Fedorkov
    Yu. P. Kharitonov
    V. S. Khrunov
    V. M. Zaletin
    Atomic Energy, 2017, 121 : 365 - 370
  • [32] CdTe and CdZnTe crystals for room temperature gamma-ray detectors
    Franc, J
    Höschl, P
    Belas, E
    Grill, R
    Hlídek, P
    Moravec, P
    Bok, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01): : 146 - 151
  • [33] CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 158 - 170
  • [34] CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    Soreq NRC, 81800 Yavne, Israel
    Nucl Instrum Methods Phys Res Sect A, 1 (158-170):
  • [35] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 297 - 309
  • [36] Screening effects in high resistivity CdTe for X-ray and gamma ray detectors
    Kubat, J.
    Franc, J.
    Grill, R.
    Horodysky, P.
    Hlidek, P.
    Belas, E.
    JOURNAL OF ELECTRONIC MATERIALS, 2007, 36 (08) : 871 - 876
  • [37] Screening Effects in High Resistivity CdTe for X-ray and Gamma Ray Detectors
    J. Kubát
    J. Franc
    R. Grill
    P. Horodyský
    P. Hlídek
    E. Belas
    Journal of Electronic Materials, 2007, 36 : 871 - 876
  • [38] X ray and gamma ray spectroscopy with segmented CdZnTe detectors
    Shor, A
    Eisen, Y
    Mardor, I
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 : 59 - 70
  • [39] Radiation Detectors for X-Ray and Gamma-Ray Spectroscopy
    G. F. Knoll
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 243 : 125 - 131
  • [40] Radiation detectors for X-ray and gamma-ray spectroscopy
    Knoll, GF
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 243 (01) : 125 - 131