Characteristics of X-ray and gamma radiation detectors based on polycrystalline CdTe and CdZnTe films

被引:3
|
作者
Utamuradova Sh.B. [1 ]
Muzafarova S.A. [1 ]
Abdugafurov A.М. [1 ]
Fayzullaev K.M. [1 ]
Naurzalieva E.M. [1 ]
Rakhmanov D.A. [1 ]
机构
[1] Institute of Semiconductor Physics and Microelectronics, the National University of Uzbekistan 20 Yangi Almazar st., Tashkent
来源
Utamuradova, Sh.B. (sh-utamuradova@yandex.ru) | 1600年 / ORION Research-and-Production Association卷
关键词
Dark current; Detector intermediate layer; Energy resolution; Film; Irradiation; Mobility; Radiation; Solid solution; Structure;
D O I
10.51368/1996-0948-2021-4-81-86
中图分类号
学科分类号
摘要
Based on CdTe and CdZnTe detectors a number of promising devices were created, which found their application in metallurgy, in solving the problems of customs control and control of nuclear materials, as well as matrix detectors created for the manufacture of medical devices and devices for space research. Detectors, created on the basis of polycrystalline semiconductor CdTe and CdZnTe films with a columnar structure on a molybdenum substrate with a thickness d = 30/150 μm, had a specific resistance P > 105108 Ω-cm. The energy resolution of the CdTe and CdZnTe detectors at room temperature reached ~ 5 keV on the 59.6 keV 241Am line. © Утамурадова Ш. Б., Музафарова С. А., Абдугафуров А. М., Файзуллаев К. М., Наурзалиева Э. М., Рахманов Д. А., 2021
引用
收藏
页码:81 / 86
页数:5
相关论文
共 50 条
  • [21] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    NASA Goddard Space Flight Center, Greenbelt, MD 20771, United States
    不详
    不详
    Nucl Instrum Methods Phys Res Sect A, 1-2 (138-145):
  • [22] Characterization of X- and Gamma-Ray CdTe Radiation Detectors
    Raulo, A.
    Sowinska, M.
    Hennard, G.
    Campajola, L.
    Marano, D.
    Paternoster, G.
    Perillo, E.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4795 - 4798
  • [23] Low noise gamma-ray and X-ray detectors based on CdTe-materials
    Abro, E
    Johansen, GA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 470 - 474
  • [24] New developments in CdTe and CdZnTe detectors for X and γ-ray applications
    L. Verger
    J. P. Bonnefoy
    F. Glasser
    P. Ouvrier-Buffet
    Journal of Electronic Materials, 1997, 26 : 738 - 744
  • [25] Preparation and characterization of polycrystalline CdZnTe films for large-area, high-sensitivity X-ray detectors
    Satoshi Tokuda
    Hiroyuki Kishihara
    Susumu Adachi
    Toshiyuki Sato
    Journal of Materials Science: Materials in Electronics, 2004, 15 : 1 - 8
  • [26] Polarization Studies of CdZnTe Detectors Using Synchrotron X-Ray Radiation
    Camarda, G. S.
    Bolotnikov, A. E.
    Cui, Y.
    Hossain, A.
    Awadalla, S. A.
    Mackenzie, J.
    Chen, H.
    James, R. B.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1798 - +
  • [27] Preparation and characterization of polycrystalline CdZnTe films for large-area, high-sensitivity X-ray detectors
    Tokuda, S
    Kishihara, H
    Adachi, S
    Sato, T
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2004, 15 (01) : 1 - 8
  • [28] Polarization Studies of CdZnTe Detectors Using Synchrotron X-Ray Radiation
    Camarda, Giuseppe S.
    Bolotnikov, Aleksey E.
    Cui, Yonggang
    Hossain, Anwar
    Awadalla, Salah A.
    MacKenzie, J.
    Chen, Henry
    James, Ralph B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3725 - 3730
  • [29] CdTe polycrystalline films for X-ray digital imaging applications
    Saucedo, E
    Corregidor, V
    Fornaro, L
    Cuña, A
    Dieguez, E
    THIN SOLID FILMS, 2005, 471 (1-2) : 304 - 309
  • [30] UNCOOLED CdTe AND CdZnTe BASED DETECTORS FOR γ-RADIATION SPECTROMETRY
    Gazizov, I. M.
    Smirnov, A. A.
    Fedorkov, V. G.
    Kharitonov, Yu. P.
    Khrunov, V. S.
    Zaletin, V. M.
    ATOMIC ENERGY, 2017, 121 (05) : 365 - 370