3-D Calibration algorithm for freehand ultrasound image

被引:1
|
作者
机构
[1] Rao, Yao
[2] Wenhua, Lu
[3] Xingyuan, Zhang
[4] Peng, Yao
来源
Peng, Y. | 1600年 / Asian Network for Scientific Information卷 / 12期
关键词
Calibration - Nondestructive examination - Probes - Phantoms - Linear transformations - Ultrasonic testing - Least squares approximations;
D O I
10.3923/itj.2013.2554.2560
中图分类号
学科分类号
摘要
3-D calibration for freehand Ultrasound (US) image is an extremely important technique to build up 3-D US image system in ultrasound Non-destructive Testing (NDT). Calibration is a procedure to calculate the spatial transformation matrix, spatial relationship between the US image plane and the tracker attached to the US probe. In this research, a different cross-string phantom and the corresponding algorithm are investigated. The strings and crosses out of the scanning plane in the phantom accelerate interactive operation speed, guiding the operator to find the scanning plane quickly. Furthermore the ten crosses in the scanning plane provide the coordinates and spatial vectors for the calibration algorithm, thus the different calibration algorithm based on the least-squares fitting method of the homologous points matching can be realized. The results show that the US probe positioning time is no more than S sec. The precision and the accuracy results show that the algorithm calculates more accunte calibration matrix than that is obtained through the other published methods in the same operating time. The results solve the obligatory pre-procedure for computerize 3-D freehand ultrasonic inNDT. © 2013 Asian Network for Scientific Information.
引用
收藏
相关论文
共 50 条
  • [31] VALIDITY OF FREEHAND 3-D ULTRASOUND SYSTEM IN MEASUREMENT OF THE 3-D SURFACE SHAPE OF SHOULDER MUSCLES
    Umehara, Jun
    Fukuda, Norio
    Konda, Shoji
    Hirashima, Masaya
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (09): : 1966 - 1976
  • [32] Median filters used for volume reconstruction in freehand 3-D ultrasound
    Huang, Qinghua
    Zheng, Yongping
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1826 - 1829
  • [33] Validation of 3-D freehand ultrasound for the determination of the hip joint centre
    Peters, Alana
    Baker, Richard
    Sangeux, Morgan
    GAIT & POSTURE, 2010, 31 (04) : 530 - 532
  • [34] Sensorless freehand 3-D ultrasound using regression of the echo intensity
    Prager, RW
    Gee, AH
    Treece, GM
    Cash, CJC
    Berman, LH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 437 - 446
  • [35] Efficient Stratified 3-D Scatterer Sampling for Freehand Ultrasound Simulation
    Gaits, Francois
    Mellado, Nicolas
    Bouyjou, Gauthier
    Garcia, Damien
    Basarab, Adrian
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 127 - 140
  • [36] Improved 3D Reconstruction Algorithm for Ultrasound B-scan Image with Freehand Tracker
    Zhao, Shuangren
    Suri, Jasjit
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [37] A robust meshing and calibration approach for sensorless freehand 3D ultrasound
    Rivaz, Hassan
    Boctor, Emad
    Fichtinger, Gabor
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [38] Actuator-Assisted Calibration of Freehand 3D Ultrasound System
    Koo, Terry K.
    Silvia, Nathaniel
    JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [39] Freehand 3D ultrasound calibration using an electromagnetically tracked needle
    Zhang, Hui
    Banovac, Filip
    White, Amy
    Cleary, Kevin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [40] A novel temporal calibration method for 3-D ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Barillot, Christian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (08) : 1108 - 1112