3-D Calibration algorithm for freehand ultrasound image

被引:1
|
作者
机构
[1] Rao, Yao
[2] Wenhua, Lu
[3] Xingyuan, Zhang
[4] Peng, Yao
来源
Peng, Y. | 1600年 / Asian Network for Scientific Information卷 / 12期
关键词
Calibration - Nondestructive examination - Probes - Phantoms - Linear transformations - Ultrasonic testing - Least squares approximations;
D O I
10.3923/itj.2013.2554.2560
中图分类号
学科分类号
摘要
3-D calibration for freehand Ultrasound (US) image is an extremely important technique to build up 3-D US image system in ultrasound Non-destructive Testing (NDT). Calibration is a procedure to calculate the spatial transformation matrix, spatial relationship between the US image plane and the tracker attached to the US probe. In this research, a different cross-string phantom and the corresponding algorithm are investigated. The strings and crosses out of the scanning plane in the phantom accelerate interactive operation speed, guiding the operator to find the scanning plane quickly. Furthermore the ten crosses in the scanning plane provide the coordinates and spatial vectors for the calibration algorithm, thus the different calibration algorithm based on the least-squares fitting method of the homologous points matching can be realized. The results show that the US probe positioning time is no more than S sec. The precision and the accuracy results show that the algorithm calculates more accunte calibration matrix than that is obtained through the other published methods in the same operating time. The results solve the obligatory pre-procedure for computerize 3-D freehand ultrasonic inNDT. © 2013 Asian Network for Scientific Information.
引用
收藏
相关论文
共 50 条
  • [21] A linear-array freehand 3-D endoscopic ultrasound
    Sumiyama, K
    Suzuki, N
    Tajiri, H
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (07): : 1001 - 1006
  • [22] A fully automatic calibration procedure for freehand 3D ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 985 - 988
  • [23] Robust and automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 440 - 448
  • [24] Statistics analysis of calibration precision for freehand ultrasound image
    Rao, Y., 2013, CESER Publications, Post Box No. 113, Roorkee, 247667, India (47):
  • [25] Rapid Calibration of 3D Freehand Ultrasound for Vessel Intervention
    Luan, K.
    Liao, H.
    Ohya, T.
    Wang, J.
    Sakuma, I.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 716 - +
  • [26] Rapid, easy and reliable calibration for freehand 3D ultrasound
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06): : 823 - 835
  • [27] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Graham, Andrew H. Gee
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [28] Accurate fiducial location for freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [29] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Gee, Andrew H.
    Treece, Graham M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (02): : 239 - 251
  • [30] 3-D ultrasound image slice acquirement using non-calibration
    Li, HY
    Xiao, Y
    Hu, SH
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 6, 2005, : 462 - 466