Monte Carlo simulation of a medical linear accelerator for filtered and FFF systems

被引:2
|
作者
Yazǧan C. [1 ]
Eçen Y.C. [2 ]
机构
[1] Department of Nuclear Medicine, Isparta City Hospital, Isparta
[2] Department of Radiation Oncology, School of Medicine, Akdeniz University, Antalya
来源
Yazǧan, Çaǧr (cagri.yazgan@gmail.com) | 2017年 / TUBITAK卷 / 41期
关键词
Linear accelerator; Monte Carlo method; Monte Carlo N-particle code; Simulation attening filter-free;
D O I
10.3906/fiz-1704-30
中图分类号
学科分类号
摘要
In order to simulate radiation transport, various algorithms, codes, and programs have been developed. In this study Monte Carlo N-particle code is used to simulate a medical electron linear accelerator gantry for research purposes. Detailed geometry of the LINAC head and water phantom are modeled and simulated for calculations. Analyses are made for filtered and attening filter-free (FFF) systems. Percent depth dose and dose profile measurements are calculated with Monte Carlo simulations and compared with experimental and theoretical values for quality assurance of the model. Flux, dose, and spectrum analyses are performed for filtered and FFF systems separately. In this study, it was aimed to run the linear accelerator in a computer environment for different purposes, and this aim was achieved. . © 2017 Tübitak.
引用
收藏
页码:498 / 506
页数:8
相关论文
共 50 条
  • [21] Basic dosimetric comparison of medical linear accelerator using FlLUKA Monte Carlo model
    Kummali, A.
    Thekkadath, S.
    Mm, M.
    Raman, G. R.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S137 - S138
  • [22] Dosimetric evaluation of a dedicated stereotactic linear accelerator using measurement and Monte Carlo simulation
    Heydarian, M.
    Asnaashari, K.
    Allahverdi, M.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2008, 35 (09) : 3943 - 3954
  • [23] Monte Carlo Simulation for Prostate SBRT Using Primo with Truebeam Stx Linear Accelerator
    Ferrari, J.
    Apaza, O.
    Chesta, M.
    Venencia, C. D.
    MEDICAL PHYSICS, 2024, 51 (10) : 7888 - 7889
  • [24] Design and characterisation of a minibeam collimator utilising Monte Carlo simulation and a clinical linear accelerator
    Carver, Antony
    Baker, Sam
    Dumbill, Andrew
    Horton, Steven
    Green, Stuart
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (13):
  • [25] Design of a spherical applicator for intraoperative radiotherapy with a linear accelerator-a Monte Carlo simulation
    Ma, P.
    Li, Y.
    Tian, Y.
    Liu, B.
    Zhou, F.
    Dai, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (01):
  • [26] Application of variance reduction techniques in Monte Carlo simulation of clinical electron linear accelerator
    Zoubair, M.
    El Bardouni, T.
    El Gonnouni, L.
    Boulaich, Y.
    El Bakkari, B.
    El Younoussi, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 (01): : 93 - 97
  • [27] Optimization Techniques and Parameters Setting of the GAMOS Code in the Monte Carlo Simulation of a Medical Accelerator
    Assalmi, Mustapha
    Diaf, El Yamani
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2022, 77 (03) : 511 - 523
  • [28] Optimization Techniques and Parameters Setting of the GAMOS Code in the Monte Carlo Simulation of a Medical Accelerator
    Mustapha Assalmi
    El Yamani Diaf
    Moscow University Physics Bulletin, 2022, 77 : 511 - 523
  • [29] A Study on Optimization of Photoneutron Shielding in a Medical Accelerator Room by Using Monte Carlo Simulation
    Kim, Yong Nam
    Choi, Sang Hyun
    Jeong, Kyoungkeun
    Kim, Joo Young
    Lee, Chang Geol
    Seong, Jinsil
    Kim, Chan Hyeong
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 50 - 53
  • [30] Geometric Calibration of a Linear Accelerator modeled with Monte Carlo
    Escobar-Corral, N.
    Bornemann, C.
    Lotze, S.
    Schmachtenberg, A.
    Stahl, A.
    Eble, M. J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 141 - 141