Improving the frosting and defrosting performance of air source heat pump units: review and outlook

被引:0
|
作者
Song M. [1 ]
Dong J. [2 ]
Wu C. [3 ]
Jiang Y. [2 ]
Qu M. [4 ]
机构
[1] School of Materials and Energy, Guangdong Provincial Key Laboratory on Functional Soft Condensed Matter, Guangdong University of Technology, Guangzhou
[2] Department of Building Thermal Energy Engineering, Harbin Institute of Technology, Harbin
[3] Building Energy Research Centre, Guangzhou HKUST Fok Ying Tung Research Institute, Guangzhou
[4] School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai
来源
Wu, Chili (chiliwu@ust.hk) | 1600年 / Taylor and Francis Asia Pacific卷 / 24期
基金
中国国家自然科学基金;
关键词
Air source heat pump (ASHP); control strategy; defrosting; frost retardation; multi-circuit outdoor coil;
D O I
10.1080/1023697X.2017.1313134
中图分类号
学科分类号
摘要
When air source heat pump (ASHP) units operate in heating mode at low temperatures in high humidity environments, frost forms and accumulates on the surface of its outdoor coils. This frost layer adversely degrades the operating efficiency of ASHP units rapidly, and can even result in sudden shutdown. Due to this operational problem, many researchers have conducted studies on frost-retardation measures. Since the frost that is present on the ASHP unit after shutdown has to be removed, defrosting becomes necessary. Among several reported defrosting methods, such as compressor shutdown defrosting, electric heating defrosting, hot water spray defrosting and hot gas bypass defrosting, the most popular method is reverse cycle defrosting. In addition, defrosting initiation and termination control play an important role in the frosting and defrosting cycle. Due to a scarcity of reviews of the literature on improving the frosting and defrosting performance of ASHP units, this paper provides a comprehensive review of experimental and modelling studies which explore this topic. This review can be used for guiding the future design and control strategy optimisation for ASHP units. © 2017 The Hong Kong Institution of Engineers.
引用
收藏
页码:88 / 98
页数:10
相关论文
共 50 条
  • [41] Evaluation method and enhanced strategy for frosting suppression performance of variable speed air source heat pump based on frosting suppression performance map
    Lin, Yao
    Luo, Jianfei
    Luo, Qing
    Li, Xiaoli
    Wang, Wei
    Sun, Yuying
    ENERGY AND BUILDINGS, 2024, 325
  • [42] Techno-economic analysis on frosting/defrosting operations for an air source heat pump unit with an optimized multi-circuit outdoor coil
    Song, Mengjie
    Tso, Chiyan
    Chao, Christopher Yuhang
    Wu, Chili
    ENERGY AND BUILDINGS, 2018, 166 : 165 - 177
  • [43] Experimental investigation of heating performance of air source heat pump with stable heating capacity during defrosting
    Liang, Chenjiyu
    Li, Xianting
    Meng, Xiangjun
    Shi, Wenxing
    Gu, Junqiang
    Wang, Baolong
    Lv, Yanbo
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [44] Frosting for airside heat exchanger of water chiller/heater of air source heat pump
    Yao, Yang
    Jiang, Yi-Qiang
    Ma, Zui-Liang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2002, 34 (05): : 660 - 662
  • [45] Frosting performance variations of variable-frequency air source heat pump in different climatic regions
    Wei, Wenzhe
    Jin, Xinyue
    Dong, Qian
    Ni, Long
    Zhao, Shunan
    Wang, Wei
    Sun, Yuying
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [46] Experimental study on hot liquid subcooling defrosting of an air source heat pump with multi-connected outdoor units
    Ma, Guoyuan
    Lu, Tianyu
    Liu, Fusheng
    Niu, Jianhui
    Xu, Shuxue
    ENERGY AND BUILDINGS, 2023, 291
  • [47] Experimental Study on Characteristics of False defrosting for Split Air Source Heat Pump
    Tang, Ruichao
    Han, Zhitao
    Zhang, Erkang
    Liu, Shuguang
    Zhang, Haiquan
    Su, Yuchang
    Wang, Songqing
    ADVANCES IN MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 220-223 : 585 - 591
  • [48] The optimal defrosting condition of an air source heat pump based on entropy analysis
    Dong, Wei
    Li, Yongcun
    Zou, Shenghua
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 13176 - 13195
  • [49] Energy transfer procession in an air source heat pump unit during defrosting
    Song Mengjie
    Xu Xiangguo
    Mao Ning
    Deng Shiming
    Xu Yingjie
    APPLIED ENERGY, 2017, 204 : 679 - 689
  • [50] A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit
    Yao, Y
    Jiang, YQ
    Deng, SM
    Ma, ZL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (17-18) : 3745 - 3756