Evaluation method and enhanced strategy for frosting suppression performance of variable speed air source heat pump based on frosting suppression performance map

被引:0
|
作者
Lin, Yao [1 ,2 ]
Luo, Jianfei [3 ]
Luo, Qing [3 ]
Li, Xiaoli [1 ]
Wang, Wei [4 ,5 ]
Sun, Yuying [4 ]
机构
[1] Beijing Univ Sci & Technol, Sch Informat Engn, Beijing, Peoples R China
[2] City Univ Hong Kong, Sch Energy & Environm, Hong Kong, Peoples R China
[3] State Key Lab Air conditioning Equipment & Syst En, Zhuhai, Peoples R China
[4] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing, Peoples R China
[5] Beijing Polytech, Beijing, Peoples R China
关键词
Variable speed; Air source heat pump; Frosting suppression performance map; Evaluation method; Evaluating the frosting suppression; performance; TEMPERATURE; OPERATION; EXCHANGER; SYSTEM; CYCLE; FIN;
D O I
10.1016/j.enbuild.2024.115047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is well established that the configuration and operation of variable speed air source heat pumps (VS ASHPs) can significantly influence their frosting performance. However, there is currently no effective method to conveniently and accurately evaluate the frosting suppression performance of these units. This paper addresses this gap by proposing a novel evaluation method based on a frosting suppression map for VS ASHPs. Firstly, an experimental setup with four ASHP units and developed frosting suppression maps is described. Second, a method for evaluating the frosting suppression performance of VS ASHP is developed based on the map. Thirdly, a comprehensive evaluation of the frosting suppression performance of the experimental unit is carried out. It is shown that the beta values of the four units under the constitutive configuration were 0.74, 0.12, 0.21, and 0.52, and the frosting suppression performance was evaluated as Good, Poor, Fair, and Average, respectively. It could be enhanced and improved to 0.89 (Excellent), 0.24 (Fair), 0.64 (Good), and 0.63 (Good) after applying the frosting suppression operation method. The proposed novel frosting suppression evaluation method is simple and easy to implement, which could contribute to further guiding manufacturers to improve the frosting suppression performance of VS ASHPs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A novel variable speed ASHP frosting suppression operation method based on the frosting suppression performance map
    Lin, Yao
    Wang, Wei
    Luo, Jianfei
    Sun, Yuying
    Deng, Shiming
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [2] Developing condensing-frosting performance maps for a variable speed air source heat pump (ASHP) for frosting suppression
    Liu, Shengnan
    Bai, Xiaoxia
    Zhang, Long
    Lin, Yao
    Deng, Shiming
    Wang, Wei
    Wei, Minchen
    APPLIED THERMAL ENGINEERING, 2022, 211
  • [3] Developing a novel control strategy for frosting suppression based on condensing-frosting performance maps for variable speed air source heat pumps
    Liu, Shengnan
    Bai, Xiaoxia
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    ENERGY AND BUILDINGS, 2023, 289
  • [4] Frosting suppression performance enhancement of air source heat pump through improving relative capacity
    Wei, Wenzhe
    Feng, Zhenglei
    Ni, Long
    Wang, Wei
    Jin, Xinyue
    Tang, Rui
    Zhao, Shunan
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [5] A modeling study on developing the condensing-frosting performance maps for a variable speed air source heat pump
    Liu, Shengnan
    Bai, Xiaoxia
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [6] Seasonal performance of air source heat pump under the frosting conditions
    Chen, Yi-Guang
    Yang, Zhao
    Ren, Yong
    Fang, Zheng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (04): : 557 - 561
  • [7] Frosting performance variations of variable-frequency air source heat pump in different climatic regions
    Wei, Wenzhe
    Jin, Xinyue
    Dong, Qian
    Ni, Long
    Zhao, Shunan
    Wang, Wei
    Sun, Yuying
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [8] Effects of evaporator frosting on the performance of an air-to-air heat pump
    Martínez-Frías, J
    Aceves, SM
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1999, 121 (01): : 60 - 65
  • [9] Improving the frosting and defrosting performance of air source heat pump units: review and outlook
    Song M.
    Dong J.
    Wu C.
    Jiang Y.
    Qu M.
    Wu, Chili (chiliwu@ust.hk), 1600, Taylor and Francis Asia Pacific (24): : 88 - 98
  • [10] A novel characteristic index for frosting suppression based on the configuration and operation of air source heat pumps
    Liang, Shimin
    Wang, Wei
    Sun, Yuying
    Li, Zhaoyang
    Zhao, Jihan
    Lin, Yao
    Deng, Shiming
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 109 : 161 - 171