Evaluation method and enhanced strategy for frosting suppression performance of variable speed air source heat pump based on frosting suppression performance map

被引:0
|
作者
Lin, Yao [1 ,2 ]
Luo, Jianfei [3 ]
Luo, Qing [3 ]
Li, Xiaoli [1 ]
Wang, Wei [4 ,5 ]
Sun, Yuying [4 ]
机构
[1] Beijing Univ Sci & Technol, Sch Informat Engn, Beijing, Peoples R China
[2] City Univ Hong Kong, Sch Energy & Environm, Hong Kong, Peoples R China
[3] State Key Lab Air conditioning Equipment & Syst En, Zhuhai, Peoples R China
[4] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing, Peoples R China
[5] Beijing Polytech, Beijing, Peoples R China
关键词
Variable speed; Air source heat pump; Frosting suppression performance map; Evaluation method; Evaluating the frosting suppression; performance; TEMPERATURE; OPERATION; EXCHANGER; SYSTEM; CYCLE; FIN;
D O I
10.1016/j.enbuild.2024.115047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is well established that the configuration and operation of variable speed air source heat pumps (VS ASHPs) can significantly influence their frosting performance. However, there is currently no effective method to conveniently and accurately evaluate the frosting suppression performance of these units. This paper addresses this gap by proposing a novel evaluation method based on a frosting suppression map for VS ASHPs. Firstly, an experimental setup with four ASHP units and developed frosting suppression maps is described. Second, a method for evaluating the frosting suppression performance of VS ASHP is developed based on the map. Thirdly, a comprehensive evaluation of the frosting suppression performance of the experimental unit is carried out. It is shown that the beta values of the four units under the constitutive configuration were 0.74, 0.12, 0.21, and 0.52, and the frosting suppression performance was evaluated as Good, Poor, Fair, and Average, respectively. It could be enhanced and improved to 0.89 (Excellent), 0.24 (Fair), 0.64 (Good), and 0.63 (Good) after applying the frosting suppression operation method. The proposed novel frosting suppression evaluation method is simple and easy to implement, which could contribute to further guiding manufacturers to improve the frosting suppression performance of VS ASHPs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil
    Song Mengjie
    Xia Liang
    Mao Ning
    Deng Shiming
    APPLIED ENERGY, 2016, 164 : 36 - 44
  • [32] Effect of supply water temperature on frosting performance of air source heat pump and indoor thermal environment in space heating
    Wang, Wei
    Di, Haoran
    Tang, Rui
    Wei, Wenzhe
    Sun, Yuying
    Dai, Chuanmin
    BUILDING AND ENVIRONMENT, 2025, 267
  • [33] Modeling and experimental investigation on comprehensive performance of perforated wavy fins for heat pump type air conditioners at frosting and non-frosting conditions
    Wu, Guoming
    Yu, Bo
    Ren, Tao
    Ding, Guoliang
    ENERGY AND BUILDINGS, 2020, 225
  • [34] Performance comparison of air source heat pump with R407C and R22 under frosting and defrosting
    Liu Zhiqlang
    Li Xiaolin
    Wang Hanqing
    Peng Wangming
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (02) : 232 - 239
  • [35] Field experimental research on retarding frosting and improving defrosting performance of air source heat pumps through variable frequency technology
    Wu, Chunling
    Wang, Zhichao
    Li, Xiaofeng
    Xu, Zhaowei
    Xu, Ce
    Yang, Yingxia
    Zhao, Wenyuan
    Wang, Yichao
    JOURNAL OF BUILDING ENGINEERING, 2023, 64
  • [36] Performance of a heat pump type air conditioner using R410A under frosting conditions
    Liu, Y.
    Wang, F.
    Wang, T.
    Liu, P.
    Xue, M.
    Wu, Z. M.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 551 - 554
  • [37] A novel Temperature-Humidity-Time defrosting control method based on a frosting map for air-source heat pumps
    Zhu, Jiahe
    Sun, Yuying
    Wang, Wei
    Ge, Yijing
    Li, Lintao
    Liu, Jingdong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 54 : 45 - 54
  • [38] An experimental study on defrosting performance for an air source heat pump unit at different frosting evenness values with melted frost local drainage
    Song, Mengjie
    Mao, Ning
    Deng, Shiming
    Xia, Yudong
    Chen, Ying
    APPLIED THERMAL ENGINEERING, 2016, 99 : 730 - 740
  • [39] Model of air source heat pump (ASHP) under frosting conditions based on finite-time thermodynamics
    Gong, Guang-Cai
    Wang, Hong-Jin
    Lv, Dong-Yan
    Su, Huan
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL. 2): : 4 - 8
  • [40] Frost suppression performance of an air source heat pump using sensible heat from indoor air to preheat outdoor air
    Wei, Peng
    Wang, Zhiwei
    Feng, Hengli
    Wang, Sheng
    Fan, Jufang
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2023, 44 (05): : 537 - 555