UPLIFT LOAD TEST USING UNIT TEST SPECIMENS FOR THE STRENGTH VERIFICATION OF TIMBER ROOF FRAMES AGAINST WIND LOAD

被引:0
|
作者
Kikitsu H. [1 ]
Yamazaki Y. [2 ]
Takadate Y. [3 ]
机构
[1] Building Dept., National Institute for Land and Infrastructure Management
[2] Dept. of Building Materials and Components, Building Research Institute
[3] Dept. of Structural Engineering, Building Research Institute
关键词
Timber roof frame; Unit test specimen; Wind load;
D O I
10.3130/aijt.30.29
中图分类号
学科分类号
摘要
Uplift load tests were carried out using two types of unit test specimens that reproduced timber roof frame. From the test using the unit test specimen of the rafter joint, it was confirmed that the method based on the simple beam model in the usual design gives the same result as this result. From the test using unit test specimens that reflect the part of roof frame, the authors tried to understand the damage process progress of the entire roof frame and to calculate the strength of the roof frame, and then compared it with the wind load. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:29 / 34
页数:5
相关论文
共 32 条
  • [1] Test study of wind load on roof of Yiwu Swimming Museum
    Research Center of Wind Engineering, Hunan Univ., Changsha 410082, China
    不详
    Hunan Daxue Xuebao, 2007, 5 (10-14):
  • [2] OPTIMIZATION AND VERIFICATION OF WIND TURBINE SIMULATION MODEL BASED ON LOAD TEST
    Wang R.
    Sun Y.
    Li T.
    Xu Y.
    Fu L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (04): : 92 - 98
  • [3] Experimental investigation of rock strength using indentation test and point load test
    Xie, Wei-Qiang
    Zhang, Xiao-Ping
    Liu, Quan-Sheng
    Tang, Shao-Hui
    Li, Wei-Wei
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2021, 139
  • [4] ESTIMATION OF STRENGTH ANISOTROPY USING THE POINT-LOAD TEST
    BROCH, E
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 1983, 20 (04): : 181 - 187
  • [5] Wind load identification using wind tunnel test data by inverse analysis
    Hwang, Jae-Seung
    Kareem, Ahsan
    Kim, Hongjin
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2011, 99 (01) : 18 - 26
  • [6] Static Uncertainty Analysis of a Wind Turbine Test Bench's Load Application Unit
    Schkoda, Ryan F.
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 3150 - 3155
  • [7] Assessment of damaged timber structures using proof load test - Experience from case studies
    Arangjelovski, Toni
    Gramatikov, Kiril
    Docevska, Marija
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 101 : 1271 - 1277
  • [8] UAV Pre-flight Structural Strength Verification during On-ground Static Load Test
    Kurnyta, Artur
    Zielinski, Wojciech
    Reymer, Piotr
    Dziendzikowski, Michal
    Dragan, Krzysztof
    2019 IEEE 6TH INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (METROAEROSPACE), 2019, : 272 - 277
  • [9] Wind Load Reduction for Ancient Pagoda Using Artificial Forest Planting via Wind Tunnel Test
    Deng Y.
    Li Y.
    Li A.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2023, 55 (03): : 58 - 68
  • [10] A new recommended load cycle for dynamic wind-resistant test of roof system based on the principle of damage equivalence
    Wu, Tao
    Sun, Ying
    Cao, Zhenggang
    Chen, Yang
    JOURNAL OF BUILDING ENGINEERING, 2022, 48