A Hardware-Software System for Accurate Segmentation of Phonocardiogram Signal

被引:4
|
作者
Movahedi M.M. [1 ,2 ,3 ]
Shakerpour M. [3 ]
Mousavi S. [3 ]
Nori A. [4 ]
Dehkordi S.H.M. [5 ]
Parsaei H. [1 ,3 ,6 ]
机构
[1] Department of Medical Physics and Biomedical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz
[2] Ionizing and Non-ioniz-ing Radiation Protection Research Center (INIR-PRC), Shiraz University of Medical Sciences, Shi-raz
[3] School of Medicine, Shiraz University of Medical Sciences, Shiraz
[4] Novin Iran Specialized Clinic, Shiraz
[5] Faculty of Electrical En-gineering, Shiraz University of Technology, Shi-raz
[6] Shiraz Neuroscience Research Center, Shiraz University of Medical Sci-ences, Shiraz
来源
关键词
Electrocardiogram; Electrocardiography; Heart Sounds; Markov Chains; PCG Segmentation; Phonocardiography;
D O I
10.31661/jbpe.v0i0.2104-1301
中图分类号
学科分类号
摘要
Background: Phonocardiogram (PCG) signal provides valuable information for diagnosing heart diseases. However, its applications in quantitative analyses of heart function are limited because the interpretation of this signal is difficult. A key step in quantitative PCG is the identification of the first and second sounds (S1 and S2) in this signal. Objective: This study aims to develop a hardware-software system for synchronized acquisition of two signals electrocardiogram (ECG) and PCG and to segment the recorded PCG signal via the information provided in the acquired ECG signal. Material and Methods: In this analytical study, we developed a hardware-software system for real-time identification of the first and second heart sounds in the PCG signal. A portable device to capture synchronized ECG and PCG signals was developed. Wavelet de-noising technique was used to remove noise from the signal. Finally, by fusing the information provided by the ECG signal (R-peaks and T-end) into a hidden Markov model (HMM), the first and second heart sounds were identified in the PCG signal. Results: ECG and PCG signals from 15 healthy adults were acquired and analyzed using the developed system. The average accuracy of the system in correctly detecting the heart sounds was 95.6% for S1 and 93.4% for S2. Conclusion: The presented system is cost-effective, user-friendly, and accurate in identifying S1 and S2 in PCG signals. Therefore, it might be effective in quantitative PCG and diagnosing heart diseases. © 2023, Shiraz University of Medical Sciences. All rights reserved.
引用
收藏
页码:261 / 268
页数:7
相关论文
共 50 条
  • [31] Memory system energy: Influence of hardware-software optimizations
    Esakkimuthu, G
    Vijaykrishnan, N
    Kandemir, M
    Irwin, MJ
    ISLPED '00: PROCEEDINGS OF THE 2000 INTERNATIONAL SYMPOSIUM ON LOW POWER ELECTRONICS AND DESIGN, 2000, : 244 - 246
  • [32] Hardware-software system for monitoring the characteristics of the cardiac conduction system
    N. M. Fedotov
    A. I. Oferkin
    S. V. Zharyi
    Biomedical Engineering, 2008, 42 (1) : 26 - 31
  • [33] VIRTUAL MEMORY - COMBINED HARDWARE-SOFTWARE MEMORY SYSTEM
    WEIZER, N
    IEEE TRANSACTIONS ON MAGNETICS, 1971, MAG7 (04) : 819 - &
  • [34] Hardware-software complex of navigation system for precision farming
    Trukhanovich, A. L.
    Kuchynski, P., V
    DEVICES AND METHODS OF MEASUREMENTS, 2012, (02): : 28 - 32
  • [35] A hardware-software system for volumetric calibration of impedance pneumograms
    Zulkarneev R.K.
    Zagidullin S.Z.
    Bakusov L.M.
    Biomedical Engineering, 2001, 35 (1) : 48 - 51
  • [36] System level hardware-software design exploration with XCS
    Ferrandi, F
    Lanzi, PL
    Sciuto, D
    GENETIC AND EVOLUTIONARY COMPUTATION GECCO 2004 , PT 2, PROCEEDINGS, 2004, 3103 : 763 - 773
  • [37] A knowledge-based system for hardware-software partitioning
    Lopez, ML
    Iglesias, CA
    Lopez, JC
    DESIGN, AUTOMATION AND TEST IN EUROPE, PROCEEDINGS, 1998, : 914 - 915
  • [38] A hardware-software system for diagnosis and correction of autonomic dysfunctions
    Kublanov V.S.
    Biomedical Engineering, 2008, 42 (4) : 206 - 212
  • [39] HARDWARE-SOFTWARE SYSTEM FOR BLOOD-PRESSURE ASSESSMENT
    HERMIDA, RC
    HALBERG, F
    DELPOZO, F
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 577 - 577
  • [40] HARDWARE-SOFTWARE TRADEOFFS IN TESTING
    STUEHLER, JE
    IEEE SPECTRUM, 1968, 5 (12) : 51 - &