A Hardware-Software System for Accurate Segmentation of Phonocardiogram Signal

被引:4
|
作者
Movahedi M.M. [1 ,2 ,3 ]
Shakerpour M. [3 ]
Mousavi S. [3 ]
Nori A. [4 ]
Dehkordi S.H.M. [5 ]
Parsaei H. [1 ,3 ,6 ]
机构
[1] Department of Medical Physics and Biomedical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz
[2] Ionizing and Non-ioniz-ing Radiation Protection Research Center (INIR-PRC), Shiraz University of Medical Sciences, Shi-raz
[3] School of Medicine, Shiraz University of Medical Sciences, Shiraz
[4] Novin Iran Specialized Clinic, Shiraz
[5] Faculty of Electrical En-gineering, Shiraz University of Technology, Shi-raz
[6] Shiraz Neuroscience Research Center, Shiraz University of Medical Sci-ences, Shiraz
来源
关键词
Electrocardiogram; Electrocardiography; Heart Sounds; Markov Chains; PCG Segmentation; Phonocardiography;
D O I
10.31661/jbpe.v0i0.2104-1301
中图分类号
学科分类号
摘要
Background: Phonocardiogram (PCG) signal provides valuable information for diagnosing heart diseases. However, its applications in quantitative analyses of heart function are limited because the interpretation of this signal is difficult. A key step in quantitative PCG is the identification of the first and second sounds (S1 and S2) in this signal. Objective: This study aims to develop a hardware-software system for synchronized acquisition of two signals electrocardiogram (ECG) and PCG and to segment the recorded PCG signal via the information provided in the acquired ECG signal. Material and Methods: In this analytical study, we developed a hardware-software system for real-time identification of the first and second heart sounds in the PCG signal. A portable device to capture synchronized ECG and PCG signals was developed. Wavelet de-noising technique was used to remove noise from the signal. Finally, by fusing the information provided by the ECG signal (R-peaks and T-end) into a hidden Markov model (HMM), the first and second heart sounds were identified in the PCG signal. Results: ECG and PCG signals from 15 healthy adults were acquired and analyzed using the developed system. The average accuracy of the system in correctly detecting the heart sounds was 95.6% for S1 and 93.4% for S2. Conclusion: The presented system is cost-effective, user-friendly, and accurate in identifying S1 and S2 in PCG signals. Therefore, it might be effective in quantitative PCG and diagnosing heart diseases. © 2023, Shiraz University of Medical Sciences. All rights reserved.
引用
收藏
页码:261 / 268
页数:7
相关论文
共 50 条
  • [21] The Hardware-Software Tango
    Prasad, K. Venkatesh
    PROCEEDINGS OF THE IEEE, 2009, 97 (07) : 1159 - 1160
  • [22] Provisioning Software with Hardware-Software Binding
    Lee, Robert P.
    Markantonakis, Konstantinos
    Akram, Raja Naeem
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON AVAILABILITY, RELIABILITY AND SECURITY (ARES 2017), 2017,
  • [23] A Hardware-Software System for Monitoring the Content of Atmospheric Impurities
    Zayakhanov, A. S.
    Zhamsueva, G. S.
    Tsydypov, V. V.
    MEASUREMENT TECHNIQUES, 2015, 58 (03) : 355 - 361
  • [24] Hardware-software system for diagnosis of venous thromboembolic complications
    Mishustin V.N.
    Titov V.S.
    Trufanov M.I.
    Biomedical Engineering, 2008, 42 (6) : 317 - 319
  • [25] MICROCOMPUTER DEVELOPMENT SYSTEM ACHIEVES HARDWARE-SOFTWARE HARMONY
    GARROW, R
    HOU, S
    LALLY, J
    WALKER, H
    ELECTRONICS, 1975, 48 (11): : 95 - 102
  • [26] Memory system energy: Influence of hardware-software optimizations
    Esakkimuthu, G.
    Vijaykrishnan, N.
    Kandemir, M.
    Irwin, M.J.
    2000, IEEE, Piscataway, NJ, United States
  • [27] A hardware-software system for the magnetographic inspection of ferromagnetic objects
    A. V. Kushner
    A. V. Shilov
    V. A. Novikov
    Russian Journal of Nondestructive Testing, 2010, 46 : 421 - 423
  • [28] Hardware-software partitioning based on system performance constrained
    Peng, Yipin
    Ling, Ming
    Yang, Jun
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2004, 34 (06): : 828 - 832
  • [29] A Hardware-Software System for Monitoring the Content of Atmospheric Impurities
    A. S. Zayakhanov
    G. S. Zhamsueva
    V. V. Tsydypov
    Measurement Techniques, 2015, 58 : 355 - 361
  • [30] A hardware-software system for the magnetographic inspection of ferromagnetic objects
    Kushner, A. V.
    Shilov, A. V.
    Novikov, V. A.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2010, 46 (06) : 421 - 423