A mixed-signal processor for X-ray spectrometry and tracking in the GAPS experiment

被引:1
|
作者
Re V. [1 ,3 ]
Ghislotti L. [1 ]
Lazzaroni P. [1 ,3 ]
Manghisoni M. [1 ,3 ]
Riceputi E. [1 ,3 ]
Ratti L. [2 ,3 ]
Boezio M. [4 ]
Zampa G. [4 ]
Fabris L. [5 ]
机构
[1] Università di Bergamo, Dipartimento di Ingegneria e Scienze Applicate, Viale Marconi 5, Dalmine
[2] Università di Pavia, Dipartimento di Ingegneria Industriale e dell'Informazione, Via Ferrata, 1, Pavia
[3] INFN, Sezione di Pavia, Via Bassi, 6, Pavia
[4] INFN, Sezione di Trieste, località Padriciano 99, Trieste
[5] Oak Ridge National Laboratory, Oak Ridge, 37831, TN
关键词
CMOS; Front-end; Noise; Readout electronics;
D O I
10.1016/j.nima.2022.167617
中图分类号
学科分类号
摘要
This paper reports the design and experimental results from the characterization of an integrated circuit developed for the readout of the X-ray spectrometer and tracking system of the General AntiParticle Spectrometer (GAPS) balloon mission. GAPS will search for an indirect signature of dark matter through the detection of low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons and antihelium nuclei. The ASIC, named SLIDER32 (32 channels Si-LI DEtector Readout ASIC), was fabricated in a 180 nm CMOS technology and is comprised of 32 analog readout channels, an 11-bit SAR ADC and a digital back-end section which is responsible for defining channel settings and for sending digital information to the data acquisition system. The core of the ASIC is a low-noise analog channel implementing a dynamic signal compression which makes the chip suitable for resolving both X-rays in the range of 20 to 100 keV and charged particles with energy deposition of up to 100 MeV. It features an energy resolution of 4 keV FWHM in the 20–100 keV range with a 40 pF detector capacitance, to clearly distinguish X-rays from antiprotonic or antideuteronic exotic atoms. The readout electronics of the ASIC will run at a temperature of about –40 °C, complying with a detector leakage current of the order of 5–10 nA per strip. © 2022 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [41] X-ray spectrometry
    Török, SB
    Lábár, J
    Schmeling, M
    Van Grieken, RE
    ANALYTICAL CHEMISTRY, 1998, 70 (12) : 495R - 517R
  • [42] X-RAY SPECTROMETRY
    TOROK, SB
    VANGRIEKEN, RE
    ANALYTICAL CHEMISTRY, 1992, 64 (12) : R180 - R196
  • [43] X-ray spectrometry
    Szalóki, I
    Török, SB
    Injuk, J
    Van Grieken, RE
    ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2895 - 2917
  • [44] X-RAY SPECTROMETRY
    MARKOWICZ, AA
    VANGRIEKEN, RE
    ANALYTICAL CHEMISTRY, 1988, 60 (12) : R28 - R42
  • [45] X-RAY SPECTROMETRY
    MARKOWICZ, AA
    VANGRIEKEN, RE
    ANALYTICAL CHEMISTRY, 1986, 58 (05) : R279 - R294
  • [46] X-RAY SPECTROMETRY
    MARKOWICZ, AA
    VANGRIEKEN, RE
    ANALYTICAL CHEMISTRY, 1990, 62 (12) : R101 - R113
  • [47] X-ray spectrometry
    Szalóki, I
    Osán, J
    Van Grieken, RE
    ANALYTICAL CHEMISTRY, 2004, 76 (12) : 3445 - 3470
  • [48] X-ray spectrometry
    Szalóki, I
    Török, SB
    Ro, CU
    Injuk, J
    Van Grieken, RE
    ANALYTICAL CHEMISTRY, 2000, 72 (12) : 211R - 233R
  • [49] A mixed-signal BiCMOS front-end signal processor for high-temperature applications
    Vermesan, Ovidiu
    Blystad, Lars-Cyril Julin
    Bahr, Roy
    Hjelstuen, Magnus
    Beneteau, Lionel
    Froelich, Benoit
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2006, 41 (07) : 1638 - 1647
  • [50] A mixed-signal SOC signal processor that incorporates all the drive electronics in a single-chip
    Bathaee, M
    Nicolae, D
    Moustoufi, Z
    Leonescu, D
    Udrea, RM
    Ghezel, H
    Andrian-Albescu, C
    Minca, I
    Fratu, O
    ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS, 2002, : 501 - 504